• 제목/요약/키워드: Leakage Reduction

검색결과 484건 처리시간 0.025초

누설전류측정을 이용한 일반용전기설비의 점검 (Inspection of General Use Electric Installation Using Leakage Current Measuring)

  • 임용배;정종욱;정진수;배석명;조성원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.63-65
    • /
    • 2006
  • A electrical fault is defined as any abnormal condition caused by a reduction in the insulation strength. To define the potential risk of the electric installation, measurement of leakage current has been getting considered, but because the measured leakage current value also contained leakage current by capacitance, the measured value could not be adapted to absolute reference to the installation. Therefore, in this paper, the correlation between the condition of electric installation and leakage current were analyzed. The result focuses on to detect them in a cost efficient way.

  • PDF

공동주택 지하주차장 누수저감을 위한 시공관리에 관한 연구 (A Study on the Construction Management in Apartment Housing's Underground Parking Lot for Reduction of Water Leakage)

  • 이재현;최일호;방중석;김효락
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.181-183
    • /
    • 2011
  • This study was carried out about construction management plan to reduce water leakage of underground parking lot in the apartment housing. To minimize effect of upper working load, installation position of jack support and paving with rubble on the top of underground parking lot were studied. By calculation shrinkage strain of underground parking lot scale, water leakage risk in design of level difference was studied. In this study, the basic data about construction management was provided to reduce water leakage of underground parking lot in the apartment housing.

  • PDF

증기터빈 래비린스 실의 형상 개선을 통한 누설량 저감에 관한 연구 (Reduction of Leakage through Labyrinth Seal in a Steam Turbine by Modification of the Teeth Shape)

  • 안중현;허진혁;문승재;이재헌;유호선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.857-862
    • /
    • 2009
  • In this study, the numerical study has carried out to analyze the leakage in a steam turbine labyrinth seal. We modified tooth shape of the labyrinth seal and finds out difference of leakage in this study. Original model is straight labyrinth seal and its modified model is slant labyrinth seal. The numerical analyses are implemented on two models. The numerical results show that each leakage of tooth shape are found 0.4781 kg/s and 0.4485 kg/s, respectively. Slant labyrinth seal seals in a steam better than straight labyrinth seal. Since, actual clearance of the stream function in the slant model is smaller than the straight model.

  • PDF

급결제의 인젝터 주입이 고유동 모르타르의 거푸집 누출량 저감 가능성 분석 (Analysis of Possibility of Reduction of Formwork Leakage of High Fluidity Mortar by Inject Accelerator)

  • 임군수;한준희;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.21-22
    • /
    • 2022
  • High fluidity concrete has excellent workability, and if the cross-section of the building is complicated, it is possible to place good quality concrete and increase the construction speed, so its utility value is very high. However, it is premised on the accuracy of concrete formwork assembly. Concrete leakage through formwork gaps is an important consideration when applying high flow concrete. In order to quickly solve the leak of high fluidity concrete caused by formwork gap occurring at the site by accelerator injection, we proceeded with research to confirm the possibility of reducing the amount of formwork leakage of high fluidity mortar. It was confirmed that the injection of the accelerator could reduce the amount of mortar leakage.

  • PDF

PWM 인버터로 구동된 유도전동기의 누설전류 억제에 관한 연구(II) -능동형 커먼 모드 전압 감쇄기를 이용한 고주파 누설전류 억제- (A Study on the Reduction of high frequency leakage current in PWM inverter fed Induction Motor)

  • 성병모;류도형;박성준;김철우
    • 전력전자학회논문지
    • /
    • 제5권5호
    • /
    • pp.443-450
    • /
    • 2000
  • PWM 인버터에 의하여 구동되는 유도전동기는 뛰어난 동작특성을 가지고 있지만, 커먼 모드 전압과 고주파 누설전류를 야기한다. 이 고주파 누설 전류는 여러가지 문제점을 일으킨다. 본 논문에서는 이러한 문제점을 일으키는 고주파 누설 전류와 커먼 모드 진압을 감쇄하기 위하여 커먼 모드 전압과 크기가 같고 반대극성을 가진 전압을 4 level half bridge 인버터를 이용하여 생성하고, 이것을 커먼 모드 transformer에 인가하여 고주파 누설 전류 역시 감쇄시킬 수 있는 새로운 형태의 능동형 커먼 모드 전압 감쇄기를 제안한다. 그리고 제안한 감쇄기의 동작 성능을 시뮬레이션과 실험을 통하여 검증하였다.

  • PDF

대기상태인 논리 회로에서의 누설전류 최소화 입력 탐색 방법 (Low Leakage Input Vector Searching Techniques for Logic Circuits at Standby States)

  • 이성철;신현철
    • 대한전자공학회논문지SD
    • /
    • 제46권10호
    • /
    • pp.53-60
    • /
    • 2009
  • 반도체 공정의 발달로 집적도가 증가하고 문턱전압이 감소하면서, 반도체 집적회로 소모 전력에서 누설전류(leakage current)의 비중이 점차 증가하고 있다. 대기 상태에서 CMOS 조합 회로(combinational circuit)는 입력 값에 따라 누설전류가 크게 달라진다. 본 연구에서는 누설전류로 인한 소모전력을 줄이기 위해 대기 상태 (standby state) 회로의 입력 신호를 제어하며, 작은 누설전류를 갖는 입력 신호를 찾기 위한 새로운 효율적인 알고리즘을 개발하였다. 이 방법을 벤치마크 예제에 실험적으로 적용하여 누설전류 평균값에 비해 15.7%, simulated evolution 방법에 비해 6.7% 누설전류를 줄일 수 있음을 보였다. 또한 순차 회로에서도 idle 입력을 이용하여 누설전류 평균값에 비해 6.8%, simulated evolution 방법에 비해 3.2% 누설전류를 줄일 수 있었다.

콘크리트 누수균열의 유지관리를 위한 누수보수용 주입형 실링재 시공방법 연구 (A Study on the Construction Methods of Sealer of Injection Type for Leakage Maintenance for Water Leakage and Cracks in Concrete)

  • 권시원;오미현;곽규성;오상근
    • 한국건축시공학회지
    • /
    • 제6권1호
    • /
    • pp.87-91
    • /
    • 2006
  • Since water leakage and cracks are not the source of serious problems such as long-term lowering of performance and durability of a stricture, including damages to operating facilities of a structure, damages to internal finishing materials, exhibition, and goods, and pollution of residential environment, they might have led to development of positive coping skills; however, an instant loss of lives or property due to earthquake, explosion, typhoon, or a fire was indeed neglected. In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if this costs a lot. It was not arrange the standard for construction methods of sealer of injection type for leakage maintenance, even it has been used various type of construction methods for leakage part. In conclusion, we suggest that the construction methods of sealer of injection type for leakage maintenance for leakage to establish the leakage repairing technology as increase of structure demand. Therefore, it would be possible to provide a stage-by-stage solution by developing systematic research activities among the industry, schools, and research institutes to spread maintenance management techniques globally through technical solution to water leakage and cracks, acquisition of structural safety with prolonged durability for life cycle, reduction of water leakage repair expense s, and so on.

밀폐된 선내 공간에서 가스 누출방향과 환기횟수에 따른 확산특성 (Diffusion Characteristics Based on the Gas Leakage Direction and Air Change per Hour in a Enclosed Space on Board a Ship)

  • 이성민;김하영;김별;황광일
    • 해양환경안전학회지
    • /
    • 제30권2호
    • /
    • pp.165-175
    • /
    • 2024
  • 수소는 기후변화 위기에 대응하기 위한 에너지원 중 하나로 주목받고 있다. 그러나, 수소는 밀폐된 공간에 누출되면 천장으로 상승하여 축적되고, 점화원과 만나면 화재나 폭발의 위험이 있다. 특히, 수소를 운송하거나 연료로 사용하는 선박은 여러 밀폐된 공간으로 구성되어 있기 때문에 수소를 안전하게 사용하기 위해서는 공간 내에서의 확산 특성을 파악해야 한다. 본 연구는 선박 내 밀폐된 공간에서 수소와 유사한 특성을 가진 헬륨의 누출방향에 따른 확산 특성을 실험적으로 파악하고, CFD 시뮬레이션을 통해 환기횟수가 25, 30, 35, 40, 45ACH로 증가함에 따라 누출방향에 따른 산소농도 변화를 파악하는 것이 목적이다. 연구 결과, 산소농도감소율은 -z 방향의 누출이 2%, +x와 +z 방향의 누출이 1%였으며, 환기소요시간은 -z 방향 누출이 15분 30초, +x 방향 누출이 7분, +z 방향 누출이 9분으로 누출방향에 따라 산소농도와 환기소요시간에 차이가 있음을 보여준다. 또한, 실험공간에서 환기횟수 35ACH 이상부터는 모든 누출 방향에서의 산소농도감소율과 환기소요시간에 유의미한 차이가 없었다. 따라서, 환기횟수를 증가하여도 산소농도와 환기소요시간이 개선되지 않았기 때문에 본 실험환경에서의 적정 환기횟수는 35ACH임을 알 수 있었다.

미케니컬 페이스 실의 유활 최적설계 (A Lubrication Design Optimization of Mechanical Face Seal)

  • 최병렬;이안성;최동훈
    • 대한기계학회논문집A
    • /
    • 제24권12호
    • /
    • pp.2989-2994
    • /
    • 2000
  • A mechanical face seal is a tribo-element intended to control leakage of working fluid at the interface of a rotating shaft and its housing. Leakage of working fluid decreases drastically as the clearance between mating seal faces gets smaller. But the very small clearance may result in an increased reduction of seal life because of high wear and heat generation. Therefore, in the design of mechanical face seals a compromise between low leakage and acceptable seal life is important, ant it present a difficult and practical design problem. A fluid film or sealing dam geometry of the seal clearance affects seal lubrication performance very much, and thereby is optimization is one of the main design consideration. in this study the Reynolds equation for the sealing dam of mechanical face seals is numerically analyzed, using the Galerkin finite element method, which is readily applied to various seal geometries, to give lubrication performances, such as opening force, restoring moment, leakage, and axial and angular stiffness coefficients. Then, to improve the seal performance an optimization is performed, considering various design variables simultaneously. For the tested case the optimization ha successfully resulted in the optimal design values of outer and inner seal radii, coning, seal clearance, and balance radius while satisfying all the operation subjected constraints and design variable side-constraints, and improvements of axial and angular stiffness coefficients by 16.8% and 2.4% respectively and reduction of leakage by 38.4% have been achieved.

나선 홈 펌프 실의 누설 및 로터다이내믹 해석 (Leakage and Rotordynamic Analysis of Spiral-Grooved Pump Seal Based on Three-Control-Volume Theory)

  • 하태웅;이안성
    • 한국유체기계학회 논문집
    • /
    • 제6권1호
    • /
    • pp.14-22
    • /
    • 2003
  • In this paper the leakage prediction md rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator is performed. For the development of a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressurized flow through the spiral groove. Validation on the present analysis is achieved by comparisons with available experimental data. For the leakage prediction the present analysis generally shows a reasonable agreement with experimental results. Rotordynamic coefficients for rotor speed with spiral angles show same trend, but the magnitudes of rotordynamic coefficients yield differences between analysis and experimental results.