• 제목/요약/키워드: Leakage Rates

Search Result 213, Processing Time 0.035 seconds

Production of SCC Flaws and Evaluation Leak Behavior of Steam Generator Tubes (누설 및 파열실험용 SCC 결함 전열관 제작 및 누설거동 평가)

  • Hwang, Seong-Sik;Jung, Man-Kyo;Park, Jang-Yul;Kim, Hong-Pyo
    • Corrosion Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.188-192
    • /
    • 2009
  • A forced outage due to a steam generator tube leak in a Korean nuclear power plant was reported.1) Primary water stress corrosion cracking has occurred in many tubes in the plant, and they were repaired using sleeves or plugs. In order to develop proper repair criteria, it is necessary to understand the leak behavior of the tubes containing stress corrosion cracks. Stress corrosion cracks were developed in 0.1 M sodium tetrathionate solution at room temperature. Steam generator(SG) tubes with short cracks were successfully fabricated with a restricted solution contact method. The leak rates of the degraded tubes were measured at room temperature. Some tubes with 100 % through wall cracks showed an increase of leak rate with time at a constant pressure.

Corrosion and Sliding Properties of the Nickel-Based Alloys for the Valve Seats Application

  • Honda, Tadashi
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.92-98
    • /
    • 2008
  • This paper describes the experiments of the corrosion and the sliding tests of the nickel-based alloys for the gate valve seating materials used at high pressure and temperature. The general corrosion rates and IGC susceptibility are tested in pressurized water at 533 K and 575 K and in Strauss test solution. The sliding tests have been done in pressurized water at 293 k, 473 K and 573 k. The alloys containing above 10% chromium may have the anti-corrosion properties that could be applied to the valve seats for the power plants. The good sliding performance and the good pressure tightness are obtained when the disc specimens that have hardness 500 to 600 Hv combined with the seat specimens that have hardness 250 to 410 Hv containing about 40 percent of iron. The large size gate valves sliding tests have certified the test results. The anti-wear properties of the seat alloy and the anti-IGC susceptibility of the disc alloy could be improved by the addition of silicon and niobium, respectively.

Degradation Characteristics of Pr/Co/Cr/Er Co-doped Zinc Oxide Varistors by Impulse Current Stress

  • Nahm, Choon-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.6
    • /
    • pp.348-352
    • /
    • 2014
  • In light of the sure protection function, the most important factors of a varistor are the clamping voltage ratio and degradation characteristics. The degradation characteristics of Pr/Co/Cr/Er co-doped zinc oxide varistors were investigated by impulse currents (0.4~2.1 kA) stress for the specified content of $Er_2O_3$ (0.5 and 2.0 mol%). The varistor doped with 2.0 mol% $Er_2O_3$ exhibited the best clamp characteristics, with the clamp voltage ratio (K) in the range of K = 1.63~1.88 at the impulse currents of 5-50 A. However, the varistor doped with 0.5 mol% exhibited excellent electrical stability, with variation rates for the breakdown field, for the nonlinear coefficient, and for the leakage current density of -6.9%, -12.6%, and -14.3%, respectively, after application of an impulse current of 2.1 kA. In contrast, the varistor doped with 2.0 mol% was destroyed after application of an impulse current of 1.2 kA.

Interleaved Current-fed High Step-up DC-DC Converter (인터리브드된 전류 주입형 고승압 DC-DC 컨버터)

  • Lee, Junho
    • Journal of IKEEE
    • /
    • v.24 no.2
    • /
    • pp.586-591
    • /
    • 2020
  • An interleaved current-fed high step-up DC-DC converter is proposed. Besides high voltage gain, a low ripple input current is achieved by adopting interleaving operation. Moreover, soft-switching characteristic of the proposed converter reduces switching losses of active power switches and raise the conversion efficiency. The reverse-recovery problem of output rectifiers is also alleviated by controlling the current changing rates of diodes by utilizing the leakage inductances of transformers. Experimental results obtained on a 200W prototype are discussed.

Vertebroplasty Utilizing Percutaneous Vertebral Body Access (PVBA) Technique for Osteoporotic Vertebral Compression Fractures in the Middle Thoracic Vertebrae

  • Cho, Yong-Jun;Choi, Jong-Hun;Cho, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.3
    • /
    • pp.161-165
    • /
    • 2007
  • Objective : Percutaneous approach to the middle thoracic vertebra through the transpedicular route for the patients with osteoporotic vertebral compression fractures is difficult due to the small size of the pedicle and parasagittally oriented vertebra body anatomy. The percutaneous vertebral body access [PVBA] technique utilizing the posterolateral extrapedicular approach avoids the pedicle and provides direct access to the vertebral body. The objective of this study is to evaluate the efficacy of the vertebroplasty utilizing PVBA technique for osteoporotic vertebral compression fractures in the middle thoracic vertebrae. Methods : A retrospective review was done on 20 patients who underwent vertebroplasty utilizing PVBA technique performed for painful osteoporotic compression fracture in the middle thoracic vertebrae at 22 levels from May 2003 to June 2006. The average amount of the injected cement was 1.5-2.5ml. The postprocedural outcome was assessed using a visual analogue scale [VAS]. Results : The treated vertebrae were T5 [1 level], T6 [5 levels], 17 [7 levels], and T8 [9 levels]. The compression rate and kyphotic angle were improved after procedure from $18%{\pm}13.4$ to $16%{\pm}13.8$ [p > 0.05] and from $6.9^{\circ}{\pm}6.7$ to $6.6^{\circ}{\pm}6.2$ [p>005], respectively. Preprocedural VAS was $8.2{\pm}0.70$ and was decreased to $2.1{\pm}1.02$ [p < 0.01] after treatment. Postprocedural cement leakage was noted in 3 levels [13.7%]. There were no cases of leakage to epidural space or neural foramen, segmental artery injury, and pneumothorax. Conclusion : These results suggest that the complication rates are low and good results can be achieved with vertebroplasty utilizing PVBA technique for the osteoporotic vertebral compression fractures especially in the middle thoracic vertebrae.

DC Accelerated Aging Characteristics of $Pr_6O_{11}$ ZnO Varistors ($Pr_6O_{11}$계 ZnO 바리스터의 DC 가속열화특성)

  • 남춘우;류정선;김향숙;정영철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.10
    • /
    • pp.808-814
    • /
    • 2001
  • The electrical properties and stabiltiy of Pr$_{6}$O$_{11}$ -based ZnO varistors, which are composed of ZnO-Pr$_{6}$O$_{11}$-Cr$_{2}$O$_{3}$-Er$_{2}$O$_{3}$ based ceramics, were investigated in the Er$_{2}$O$_{3}$ content range of 0.5 to 2.0 mol%. As Er$_{2}$O$_{3}$content is increased up to approximaterly 1.0mol%, the nonlinearity was decreased. Increasing Er$_{2}$O$_{3}$ content further caused the nonlinearity to increase. The varistors with 2.0 mol% Er$_{2}$O$_{3}$ exhibited a high nonlinearity, in which the nonlinear exponent is 47.41 and the leakage current is 1.82 $\mu$A. Furthermore, they showed a very excellent stability, in which the variation rates of the varistor voltage, the nonlinear exponent, and leakage current are -0.52%, -4.09%, and 152.75%, respectively, under DC accelerated aging stress, such as (0.80 V$_{1mA}$9$0^{\circ}C$/12h)+(0.85 V$_{1mA}$115$^{\circ}C$/12h)+(0.90 V$_{1mA}$12$0^{\circ}C$/12h)+(0.95 V$_{1mA}$1$25^{\circ}C$/12h)+(0.95 V$_{1mA}$1$25^{\circ}C$/12h).2h).TEX>/12h).2h).

  • PDF

Fabrication and Characterization of Composite Sealants for Low Temperature (600∼650°C)SOFCs (저온작동 (600∼650°C) SOFC용 복합밀봉재 제조 및 평가)

  • Lim, Hyun-Yub;Kim, Hyoung-Chul;Choi, Sun-Hee;Kim, Hae-Ryoung;Son, Ji-Won;Lee, Hae-Weon;Lee, Jong-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.45 no.12
    • /
    • pp.802-806
    • /
    • 2008
  • A proper sealant for low temperature SOFCs should show zero or low leak rates to avoid direct mixing of the fuel and oxidant gases or leakage of fuel gas during the operation of SOFCs. Furthermore, it should be chemically and/or mechanically stable in both oxidizing and reducing environments and chemically compatible with other fuel cell components. In the present work, we developed a novel compressed seal gasket of glass-based composite reinforced with ceramic particulate particles, which can efficiently control the viscous flow of glass matrix as well as the crystallization of glass phase. This novel sealing gasket showed excellent gas tightness under very low compressive load which would be suitable for the operation of SOFCs in the temperature range $600{\sim}650^{\circ}C$.

Formation of SiOF Thin Films by FTES/$O_2$-PECVD Method (FTES/$O_2$-PECVD 방법에 의한 SiOF 박막형성)

  • Kim, Duk-Soo;Lee, Ji-Hyeok;Lee, Kwang-Man;Gang, Dong-Sik;Choe, Chi-Kyu
    • Korean Journal of Materials Research
    • /
    • v.9 no.8
    • /
    • pp.825-830
    • /
    • 1999
  • Characteristics of SiOF films deposited by a FTES/$O_2$-plasma enhanced chemical vapor deposition method have been investigated using Fourier transform infrared spectroscopy, X-ray photoelectro spectroscopy, and ellipsometry. Electrical properties such as dielectric constant, dielectric breakdown and leakage current density are investigated using C-V and I-V measurements with MIS(Au/SiOF/p-Si) capacitor structure. Stepcoverage of the films have been also characterized using scanning electron microscopy and ellipsometry. A high quality SiOF film was formed on that the flow rates of FTES and $O_2$were 300sccm, respectively. The dielectric constant of the deposited SiOF film was about 3.1. This value is lower than that of the oxide films obtained using other method. The dielectric breakdown field and leakage current are more than 10MV/cm and about $8[\times}10^{9}A/\textrm{cm}^2$, respectively. The deposited SiOF film with thickness as $2500{\AA}$ on the $0.3{\mu}{\textrm}{m}$ metal pattern shows a high step-coverage without a void.

  • PDF

Reoperations for valvular heart disease: report of 29 cases (심장판막 재수술: 29례 보)

  • 김은기
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.498-505
    • /
    • 1983
  • It has been over 20 years since successful operations of Cardiac valves at the Department of Thoracic and Cardiovascular surgery, college of medicine, Yonsei University. About six hundreds of patients with severely symptomatic valvular heart disease have had valve operations with complete loss or sharp decrease in their cardiac symptoms since 1956. As the number of cardiac patient increases, reoperation on valves assumes greater importance. To define the group of patients undergoing reoperations on valves and the factors influencing their survival, we have reviewed our experiences of the reoperation on valves at the Yonsei University, Severance Hospital. This is a report of 29 cases which was undergone secondary or more surgery for valvular heart disease from 1966 to 1983. The primary operations includes 159 cases of open heart surgery from 1966 to 1975 and 476 cases from 1976 to march, 1983. The secondary operations are classified into groups of secondary valvuloplasty or valvotomy [8 cases], prosthetic valve replacement following valvuloplasty or valvotomy [14 cases] and prosthetic valve rereplacement [2 case] for such as calcification, degeneration and perforation of the cusps and paravalvular leakage, of the bioprosthetic valves. The leading indication for reoperation of mitral valve was restenosis or stenoinsufficiency, The indications of aortic valve replacement was active bacterial endocarditis, medically uncontrollable prosthetic endocarditis or paravalvular leakage. Overall death rate of the reoperation was 17.4% [5 death among the 29 patients] and the leading causes of death were myocardial failure, arrhythmia, cerebral embolism, acute renal failure due to low output syndrome. And it was followed by sepsis associated with active prosthetic endocarditis. The death rate of reoperation was 4.3% in the elective cases except urgent cases and the death rate of overall cardiac valve except reoperation cases was 4.1% in the last two years. Although the general mortality of reoperation was high, both mortality rates were comparable except emergency cases due to urgent preoperative patient’s condition.

  • PDF

A Study on the Characteristics of NbOx Thin Film at Various Frequencies of Pulsed DC Sputtering by In-Line Sputter System (인라인 스퍼터 시스템을 이용한 펄스의 주파수 변화에 따른 NbOx 박막 특성에 관한 연구)

  • Eom, Jimi;Oh, Hyungon;Kwon, Sang Jik;Park, Jung Chul;Cho, Eou Sik;Cho, Il Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.1
    • /
    • pp.44-48
    • /
    • 2013
  • Niobium oxide($Nb_2O_5$) films were deposited on p-type Si wafers at room temperature using in-line pulsed-DC magnetron sputtering system with various frequencies. The different duty ratios were obtained by varying the frequency of pulsed DC power from 100 to 300 kHz at the fixed reverse time of $1.5{\mu}s$. From the thickness of the sputtered $NbO_x$ films, it was possible to obtain much higher deposition rate in case of pulsed-DC sputtering than RF sputtering. However, the similar leakage currents and structural characteristics were obtained from the metal-insulator-semiconductor(MIS) structure fabricated with the $NbO_x$ films and the x-ray photoelectron spectroscopy(XPS) results in spite of the different deposition rates. From the experimental results, the $NbO_x$ films sputtered by pulsed-DC sputtering are expected to be used in the fabrication process instead of RF sputtering.