• 제목/요약/키워드: Leakage Loss

검색결과 617건 처리시간 0.023초

새로운 유도전동기 손실 최소화 벡터제어 (New Loss Minimization Vector Control for Induction Motors)

  • 이홍희;예르가낫
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1140-1145
    • /
    • 2011
  • This paper proposes a new loss minimization control method for the vector controlled induction motors. The aim of the proposed loss minimization method is how to determine the optimal flux reference to minimize the total loss of induction motor. Even though the proposed algorithm is based on the equivalent circuit of induction motor including iron loss and leakage inductance, the algorithm is easy to be found and simple to be implemented. Futhermore, the proposed loss minimization algorithm can be applied easily to the traditional vector control system without any additional hardware. Simulation and experimental results are given to validate the effectiveness of the proposed method.

블루투스 기반 스마트 USB 메모리 구현 (Implementation of Smart USB Memory based on Bluetooth)

  • 강병관;우승헌;유현주;주해인;이주원;강성인
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 춘계학술대회
    • /
    • pp.522-524
    • /
    • 2015
  • USB 메모리는 휴대형 보조기억장치로써 보편화되어 있다. 그러나 USB 메모리는 사용 중 분실 및 도난에 의하여 개인정보유출이 문제가 되고 있다. 따라서 재구매가 늘어나고 정보유출에 의한 개인 및 기업들의 피해사례가 늘고 있다. 따라서, 본 논문에서는 스마트 폰과 블루투스로 연동하여 USB 분실을 방지하고, 분실 시 보안 기능을 지원 할 수 있는 Bluetooth 기반 스마트 USB 메모리 시스템을 제안한다.

  • PDF

High-Isolation SPDT RF Switch Using Inductive Switching and Leakage Signal Cancellation

  • Ha, Byeong Wan;Cho, Choon Sik
    • Journal of electromagnetic engineering and science
    • /
    • 제14권4호
    • /
    • pp.411-414
    • /
    • 2014
  • A switch is one of the most useful circuits for controlling the path of signal transmission. It can be added to digital circuits to create a kind of gate-level device and it can also save information into memory. In RF subsystems, a switch is used in a different way than its general role in digital circuits. The most important characteristic to consider when designing an RF switch is keeping the isolation as high as possible while also keeping insertion loss as low as possible. For high isolation, we propose leakage signal cancellation and inductive switching for designing a singlepole double-throw (SPDT) RF switch. By using the proposed method, an isolation level of more than 23 dB can be achieved. Furthermore, the heterojunction bipolar transistor (HBT) process is used in the RF switch design to keep the insertion loss low. It is demonstrated that the proposed RF switch has an insertion loss of less than 2 dB. The RF switch operates from 1 to 8 GHz based on the $0.18-{\mu}m$ SiGe HBT process, taking up an area of $0.3mm^2$.

기판온도에 따른 (Ba,Sr)TiO$_3$ 박막의 구조와 유전특성 (The Structure and Dielectric Properties of the (Ba,Sr)TiO$_3$ Thin Films with the Substrate Temperature)

  • 이상철;이문기;이영희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권11호
    • /
    • pp.603-608
    • /
    • 2000
  • $(Ba, Sr)TiO_{3}$[BST] thin films were fabricated on the Pt/TiO$_2$/SiO$_2$/Si substrate by the RF sputtering. The structure and dielectric properties of the BST thin films with the substrate temperature were investigated. Increasing the substrate temperature, The BST phase increased and barium multi titanate phases decreased. Increasing the frequency, the dielectric constant decreased and the dielectric loss increased. The dielectric constant and dielectric loss of the BST thin films deposited at 50$0^{\circ}C$ were 300 and 0.018, respectively at 1 kHz. The leakage current density of the BST thin films deposited at 50$0^{\circ}C$ was $10^{-9}$ A/$\textrm{cm}^2$ with applied voltage of 3V. Because of the high dielectric constant(300), low dielectric loss(0.018) and low leakage current($10^{-9}$ A/$\textrm{cm}^2$), BST thin films deposited at 50$0^{\circ}C$ is expecting for the application of DRAM.

  • PDF

축류형 유체기계에서 익단 누설 유동 해석을 위한 난류 모델 성능 평가 (Performance Assessment of Turbulence Models for the Prediction of Tip Leakage Flow in an Axial-Flow Turbomachinery)

  • 이공희;백제현
    • 대한기계학회논문집B
    • /
    • 제27권12호
    • /
    • pp.1655-1666
    • /
    • 2003
  • It is experimentally well-known that high anisotropies of the turbulent flow field are dominant inside the tip leakage vortex, which is attributable to a substantial proportion of the total loss and constitutes one of the dominant mechanisms of the noise generation. This anisotropic nature of turbulence invalidates the use of the conventional isotropic eddy viscosity turbulence models based on the Boussinesq assumption. In this study, to check whether an anisotropic turbulence model is superior to the isotropic ones or not, the results obtained from the steady-state Reynolds averaged Navier-Stokes simulations based on the RNG k-$\varepsilon$ model and the Reynolds stress model (RSM) are compared with experimental data for two test cases: a linear compressor cascade and a forward-swept axial-flow fan. Through this comparative study of turbulence models, it is clearly shown that the RSM, which can express the production term and body-force term induced by system rotation without introducing any modeling, should be used to predict quantitatively the complex tip leakage flow, especially in the rotating environment.

스톨 근처에서 원심압축기 임펠러의 내부 유동현상에 관한 연구 (Analysis of Flow Phenomena in a Centrifugal Compressor Impeller Operating near Stall)

  • 음학진;강신형
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.330-337
    • /
    • 2004
  • Analysis of flow phenomena in a centrifugal compressor impeller has been carried out with numerical simulation to understand the physics of flow near stall. Near stall point, tip leakage flow spills ahead of the leading edge of adjacent blade and other leakage flow passes over the clearance of the adjacent blade instead of rolling up into vortex within the passage. The tip leakage flow at the mid chord of impeller blade impinges against the pressure surface of the adjacent blade and then rolls up into vortex within the passage, which blocks the flow passage and generates viscous loss. The spillage of leakage flow ahead of the adjacent blade generates the recirculation of flow entering the impeller, which causes the power transferred into the flow by the impeller to decrease and blocks the flow passage. Near diffuser hub wall, flow recirculation occurs. As operating point goes to stall point, the core of recirculation approaches the impeller exit The length rises to peak point and then drops with mass flow reduction, while the height steadily rises.

아크릴 수지계 수팽창성 누수보수재의 재료적 성능평가에 관한 실험적 연구 (A Experimental Study on the Performance Test of Water Leakage Repair Materials for Water Expansion Acrylic Resin)

  • 홍채훈;김수련;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 춘계 학술기술논문발표대회 논문집
    • /
    • pp.51-56
    • /
    • 2005
  • It does not find for solution by limitation of technological mechanism of existent of leakage maintenance material. So, it is paid for huge expense because continuous repeat maintenance work is consisting. Furthermore, it is indicated by big problem in construction work that is constructed by field experience that thing by definite and systematic theory is not with proper performance test and analysis up to now. Therefore, wish to measure physical performance change by various environment condition maintenance of structure and performance construction work aspect in that apply to water leakage maintenance material using of acrylic resin system water expansion, leakage maintenance material in this research, and present suitable form of construction work under these environment. also, wish to ready diversified remedy by oversea market opening.

  • PDF

Analysis of Slot Leakage Reactance of Submersible Motor with Closed Slots during Starting Transient Operation

  • Bao, Xiaohua;Di, Chong;Fang, Yong
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.135-142
    • /
    • 2016
  • Generally, closed slots are adopted to reduce the water friction loss in both the stator and the rotor of water filling submersible motor due to the special environment of operation. One of the obvious differences between the traditional induction motors and water filling submersible motors is that the submersible motors only need relatively smaller starting torque. This paper aims to analyze the slot leakage reactance of water filling submersible motor during starting transient operation. An improved analytical method which considered the magnetic saturation of the slot bridge and the skin effect of rotor bars is proposed. The slot permeance factor which has a direct impact on the slot leakage reactance is calculated. Then finite element models with different stator slot types are constructed and search coils are introduced to measure the slot flux linkage. Moreover, the starting performances of the models with two typical stator slots are compared and the flux leakage characteristics are obtained. Finally, the results obtained by finite element method are very close to the results obtained by analytical method.

모래자갈과 누수성 토질을 기반으로하는 용수로의 누수방지에 대한 연구 (A Study on the Leakage Interception Work in the Irrigation Canal Founding on the Sandy Gravel or the Porous Soil)

  • 강신업
    • 한국농공학회지
    • /
    • 제12권2호
    • /
    • pp.1965-1970
    • /
    • 1970
  • The experiment was carried out in order to improve the leakage stopping work in the irrigation canal founding on the porous soil. But the experiment had many problems to be studied more owing to the insufficient time and facilities. The results obtained are summarized as follows; 1. Polyethylene film is estimated not to make strength decrease owing to buring in the subsoil, but to make owing to the sunlight. 2. Coated nylon shows the tendency to deteriorate strength when it is buried in the earth or exposed to the sun for long time, but leakage is all but impermeability generally. 3. Leakage loss rates for one hour show some differences in the canal to be full with water in accordance with operating methods, that is, the clay lining section is 12.6%, the coated nylon lining section is 1.7%, the polyethylene film lining section is 1.3%, respectively. 4. Leakage quantities per wetted perimeter unit area show $3.556cc/cm^2/hr$. in the clay lining section, $1.574cc/cm^2/hr$. in the coated nylon section, $0.695cc/cm^2/hr$. in the polyethylene film lining section, respectively. 5. When the construction fund make the clay lining section as a standard, the polyethylene film section is 92.1%, the coated nylon section is 174.2%, respectively. But, the unit cost of execution may be low when the polyethylene film and the coated nylon will enable to mass-produce for the purpose of execution.

  • PDF