• Title/Summary/Keyword: Leakage Analysis

Search Result 2,009, Processing Time 0.029 seconds

Transient Analysis and Experiment Considering Unsteady Friction and Leakage in a Pipeline System (단일관망에서 누수효과를 고려한 천이류 분석 및 실험)

  • Lee, Mi-Hyun;Song, Yong-Sok;Kim, Sang-Hyun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1395-1399
    • /
    • 2006
  • The current paper focuses the analysis of leakage detection in water pipeline systems by means of the transient analysis. In order to obtain pressure variation for evaluation the existing methodology, an extensive experimental process has been carried out in a single pipeline system. Several experimental tests were performed with and without a leakage in the system. Using the unsteady friction and improved unsteady friction factors, reasonable match between the computed and measured pressure were presented on the condition of the flow situations. The transient method attempts to estimate the leakage in water pipelines using observed pressure data collected during transient events on the system.

  • PDF

Comparisons between Analysis and Experiment for Leakage Flowrate and Stability depending on the Effect of the Height and the Length of Floating Ring Seal (플로팅 링 실의 길이와 높이 효과에 따른 누수 및 안정성에 대한 해석과 실험의 비교)

  • An, Kyoung-Min;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Woong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.329-336
    • /
    • 2004
  • The lock-up position of the floating ring seal affects the leakage flowrate and the stability. And it is changed depending on the operating and geometry condition. In this paper, the leakage flowrate and stability with change of the height and length were investigated by theoretical analysis and experiment. The parameter of the height and length is expressed to the b and L. The decreasing of the b resulted in the increasing of equivalent whirl frequency ratio in the experimental result at the low speed and high pressure not such as theoretical analysis. As the L increased the leakage flowrate decreased and stiffness and direct damping coefficient increased in the experimental result. That was similar to the theoretical analysis.

  • PDF

Water Leakage Detection Monitoring Simulation using Power Spectrum Analysis (파워스펙트럼 분석을 이용한 누수탐지 모니터링 시뮬레이션)

  • Chung, Kyung-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.1
    • /
    • pp.48-54
    • /
    • 2013
  • With the development of IT convergence technology and the construction of infrastructure for water leakage detection, the detection technology of damaged pileline's location and size is being spotlighted. The exhaustion of water resource due to the leakage of water supply facilities renders it urgent to detect water leakage effectively. In this paper, we proposed the water leakage detection monitoring simulation using the power spectrum analysis. We measured the reflected wave signal by the proposed water leakage detection monitoring simulation. The rate variability is calculated form the acquired reflected wave signal. And the power spectrum analysis using the Fast Fourier Transform is evaluated the correlation between the water leakage's size and the reflected wave. Ultimately, this paper suggests empirical simulation to verify the adequacy and the validity. Accordingly, the satisfaction and the quality of services will be improved the efficient management by supporting the real-time water leakage detection.

The Error Analysis of Leak Measurement for Pneumatic Cylinder Using Isothermal Chamber

  • Jang, Ji-Seong;Ji, Sang-Won;Kagawa, Toshiharu
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.5 no.1
    • /
    • pp.6-12
    • /
    • 2008
  • ISO pneumatic cylinder reliability test requires air leakage measurement. Air cylinder has many parts and the leakage shall be measured before, during and after endurance test, and, the leakage should smaller than the specified value. The existing measurement method needs complex operation and the calibration of leak detector, and, has to separate the testing cylinder from endurance test device, which causes the change of contact condition of seal in the cylinder. Therefore, it is hard to evaluate the air leakage during endurance test, and guarantee the reliability of the conventional measurement method. In this paper, a new method for air leakage measurement using isothermal chamber, which does not requires calibration or temperature compensation, and, can measure air leakage accurately with quite simple operations, is proposed. As a result, reliability of air leakage measurement can be improved because the proposed method does not have to separate the testing cylinder from the endurance test device for air leakage measurement. The effectiveness of the proposed method is proved by error analysis of leak measurement from experimental result.

  • PDF

Measurement Device of Resistive Leakage Current for Arrester Deterioration Diagnosis (피뢰기 열화진단을 위한 저항분 누설전류의 측정장치)

  • 길경석;한주섭;김정배
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.10
    • /
    • pp.469-475
    • /
    • 2003
  • Resistive leakage current flowing ZnO blocks increases with its ages, which is an important indicator of arrester deterioration. However, a complicated circuitry is essential to measure the resistive leakage current included in the total leakage current, and the difficult handling of the measurement makes few applications to the fields. In this paper, we propose a resistive leakage current measurement device which is composed of a current detection circuit and an analysis program operated on a microprocessor. The device samples the input leakage current waveform digitally, and discriminate the zero-cross and the peak point of the waveform to analyze the current amplitude vs. phase. The capacitive leakage current is then eliminated from the total leakage current by using an algorithm to extract the resistive leakage current only. Also, the device can be operated automatically and manually to analyze the resistive leakage current even when the leakage current waveform is distorted due to various types of arrester deterioration. To estimate the performance of the device, we carried out a test on ZnO blocks and lightning arresters. From the results, it is confirmed that the device could analyze most parameters needed for the arrester diagnostics such as total leakage current. resistive leakage current, and the $3^rd$ harmonic leakage current.

A leak detection and 3D source localization method on a plant piping system by using multiple cameras

  • Kim, Se-Oh;Park, Jae-Seok;Park, Jong Won
    • Nuclear Engineering and Technology
    • /
    • v.51 no.1
    • /
    • pp.155-162
    • /
    • 2019
  • To reduce the secondary damage caused by leakage accidents in plant piping systems, a constant surveillance system is necessary. To ensure leaks are promptly addressed, the surveillance system should be able to detect not only the leak itself, but also the location of the leak. Recently, research to develop new methods has been conducted using cameras to detect leakage and to estimate the location of leakage. However, existing methods solely estimate whether a leak exists or not, or only provide two-dimensional coordinates of the leakage location. In this paper, a method using multiple cameras to detect leakage and estimate the three-dimensional coordinates of the leakage location is presented. Leakage is detected by each camera using MADI(Moving Average Differential Image) and histogram analysis. The two-dimensional leakage location is estimated using the detected leakage area. The three-dimensional leakage location is subsequently estimated based on the two-dimensional leakage location. To achieve this, the coordinates (x, z) for the leakage are calculated for a horizontal section (XZ plane) in the monitoring area. Then, the y-coordinate of leakage is calculated using a vertical section from each camera. The method proposed in this paper could accurately estimate the three-dimensional location of a leak using multiple cameras.

Leakage and Rotordynamic Analysis of Spiral-Grooved Pump Seal Based on Three-Control-Volume Theory (나선 홈 펌프 실의 누설 및 로터다이내믹 해석)

  • Ha, Tae-Woong;Lee, An-Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.14-22
    • /
    • 2003
  • In this paper the leakage prediction md rotordynamic analysis of an annular seal with a smooth rotor and spiral-grooved stator is performed. For the development of a theoretical model, the three-control-volume analysis of the circumferentially-grooved seal is expanded by considering pressure reduction due to the pumping effect of spiral groove and pressurized flow through the spiral groove. Validation on the present analysis is achieved by comparisons with available experimental data. For the leakage prediction the present analysis generally shows a reasonable agreement with experimental results. Rotordynamic coefficients for rotor speed with spiral angles show same trend, but the magnitudes of rotordynamic coefficients yield differences between analysis and experimental results.

Study on the Leakage Flow and the Flow Analysis of Regenerative Pump (재생펌프의 누설 유동 및 내부 유동에 관한 연구)

  • Shim Chang-Yeul;Kang Shin-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.593-596
    • /
    • 2002
  • Flows in a regenerative pump were calculated for several flow-rates, using the CFX-Tascflow. The calculated results show the vortex structure in the impeller and side channel. The predicted performance shows considerable discrepancy form the measured values for low flow rates. Main source of the difference is the leakage flow of pump strongly affecting the performance of pump. A simple correlation was proposed using calculated leakage flows through the parametric calculations of the simplified passage.

  • PDF

Analysis of Leakage Inductance for Toroidal Type Flyback Transformer (토로이달 타입 플라이백 변압기의 누설 인덕턴스 해석)

  • Park, Chang-Soo;Kang, Byeong-Geuk;Shin, Kyoung-Gu;Chung, Se-Kyo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.164-172
    • /
    • 2014
  • This paper presents an analysis of a leakage inductance for a toroidal type flyback transformer. The equation to calculate the leakage inductance is derived using the MMF diagram of the transformer. The analysis for the different types of the cores and winding structures is also provided using the FEM simulation. The winding structures minimizing the leakage inductance are finally discussed from the simulation and experimental results.

Harmonics Analysis of Leakage Current Waveforms and Surface Discharge for EPDM Polymer Insulator (EPDM 고분자 애자에 대한 표면방전 및 누설전류파형의 고조파분석)

  • 박재준;양태규
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.1013-1021
    • /
    • 2004
  • This paper presents the results of spectrum analysis of leakage current waveforms on contaminated polymer insulators under fog conditions. This is a basic study on development of a monitoring for aging degree and surface pollution state using distortion rate(%) of 3rd and 5th harmonics according fundamental frequency[60Hz] under environment conditions. Arcing on the surface was always associated with distortion in the leakage current ; hence the low frequency components of the leakage current can be used as a means to evaluate the surface degradation. The results indicate that the distortion rate by spectrum analysis is available for the monitoring of contamination condition of EPDM Polymer insulators.