• 제목/요약/키워드: Leak location

검색결과 91건 처리시간 0.024초

Assessment of Leak Detection Capability of CANDU 6 Annulus Gas System Using Moisture Injection Tests

  • Nho, Ki-Man;Kim, Wang-Bae;Sim, Woo-Gun
    • Nuclear Engineering and Technology
    • /
    • 제30권5호
    • /
    • pp.403-415
    • /
    • 1998
  • The CANDU 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside the calandria tube and the annulus between these tubes, which forms a closed loop with $CO_2$ gas recirculating, is called the Annulus Gas System(AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tube rupture incident. To judge whether the operator action time is enough or not in the design of Wolsong 2,3 & 4, the Leak Before Break(LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsong Units 2, 3, 4, a series of leak detection capability tests was performed by injecting controlled rates of heavy water vapour. The data of increased dew point and rates of rise were measured to determine the alarm set point for the dew point rate of rise of Wolsong Unit 2. It was found that the response of the dew point depends on the moisture injection rate, $CO_2$ gas flow rate and the leak location. The test showed that CANDU 6 AGS can detect the very small leaks less than few g/hr and dew point rate of rise alarm can be the most reliable alarm signal to warn the operator. Considering the present results, the first response time of dew point to the AGS $CO_2$ flow rate is approximated.

  • PDF

저압확장파 검출을 통한 배관 누출 및 누출위치 예측 (Leak and Leak Point Prediction by Detecting Negative Pressure Wave in High Pressure Piping System)

  • 하태웅;하종만;김동혁;김영남
    • 한국가스학회지
    • /
    • 제11권4호
    • /
    • pp.47-53
    • /
    • 2007
  • 고압 가스 배관망의 안전관리는 매우 중요한 문제로 배관의 외적 손상으로 구멍이 생길 경우 발생하는 누출은 폭발 및 환경오염을 포함한 막대한 경제적 손실을 야기할 수 있다. 누출 검지를 위한 PLDS(Pipeline leak detection system린 기술로 저압확장파 검지 기술이 적용되고 있으며 본 논문에서는 CFD++ 상용코드를 활용하여 배관 누출시 유동특성을 이론적으로 해석하여 저압확장파의 발생 메커니즘과 음속으로 확장되는 전파특성을 규명하였다. 또한 긴 배관망에 적용하기 위한 1차원 해석 방법을 제시하고 신뢰성을 CFD해석 결과로 검증하였다.

  • PDF

LNG 추진선의 천연가스 배관에서 누출 시나리오에 따른 피해범위에 관한 연구 (A Study on the Damage Range According to Leakage Scenarios in Natural Gas Pipeline of LNG Fueled Ship)

  • 이윤호
    • 해양환경안전학회지
    • /
    • 제26권4호
    • /
    • pp.317-326
    • /
    • 2020
  • 본 연구에서는 LNG 추진선에서 배관의 파손으로 천연가스가 누출되었을 때 누출공의 크기별 플래시 화재, 과압, 복사열에 따른 피해범위를 ALOHA(Areal Location of Hazardous Atmospheres)를 이용하여 산출했다. 그리고 민감도 분석을 위해 환경 변수(풍속, 대기온도, 대기 안정도)와 공정 변수(배관 압력, 배관 길이)로 구분하여 다양한 시나리오별 피해영향범위를 분석했다. 그 결과 환경 변수에 따른 피해범위는 플래시 화재에 의한 피해범위가 가장 컸으며 다음으로 과압, 복사열 순서로 큰 피해범위를 나타냈다. 그리고 공정 변수에 따른 피해범위를 산출한 결과 배관의 압력과 길이, 누출공의 크기와 관계없이 플래시 화재에 의한 피해범위가 가장 컸으며, 환경 변수와 동일하게 과압, 복사열 순서로 높은 피해범위를 보였다. 또한 누출공의 크기가 클수록 환경 변수와 공정 변수가 피해범위에 큰 영향을 주었으며 제트 환재에 의한 피해범위는 환경 변수에 비해 공정 변수에 의한 피해범위가 더 큰 것을 알 수 있었다.

고압 배관망에서 배관 손상에 의한 누출 및 관내 저압확장파의 전파 특성 해석 (Analysis of Propagation of Negative Pressure Wave Due to Leak Through Damaged Hole in High Pressure Piping System)

  • 김왕연;하종만;하태웅
    • 한국유체기계학회 논문집
    • /
    • 제11권1호
    • /
    • pp.26-32
    • /
    • 2008
  • The safe operation of high pressure pipe line systems is of significant importance. Leaks due to faulty operation from the pipelines can lead to considerable product losses and to exposure of community to dangerous gases. There are several leak detection methods of pipeline network which have recently been suggested. The negative pressure wave detection technology, which has advantages of short time detection availability, accurate leaking location estimate capability and cost effective, is concentrated in this study. Theoretical analysis of the flow characteristics for leaking through a hole on the pipe wall has been performed by using Fluent 6.3, commercial CFD package. The results of 3-dimensional analysis near leaking hole confirm the occurrence of negative pressure wave, and the results of 2-dimensional analysis verify the characteristics of propagation of the wave which travels with speed equal to the speed of sound in the pipeline contents. Characteristics of leakage and pressure in a pipe with a hole have been analyzed for the various pipe and hole sizes.

Feasibility study of a resistive-type sodium aerosol detector with ZnO nanowires for sodium-cooled fast reactors

  • Jewhan Lee;Da-Young Gam;Ki Ean Nam;Seong J. Cho;Hyungmo Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2373-2379
    • /
    • 2023
  • In sodium systems, leakage is one of the safety concerns; it can cause chemical reactions, which may result in fires. There are contact and non-contact types of leak detectors, and the conventional method of non-contact type detection is by gas sampling. Because of the complexity of this method, there has always been a need for a simple gas sensor, and the resistive-type nanostructure ZnO sensor is a promising option with various advantages. In this study, a ZnO sensor was fabricated, and the concept was tested as a leak detector using a dedicated experiment facility. The experiment results showed distinctive changes in resistance with the presence of sodium aerosol under various conditions. Replacing the conventional gas sampling with the ZnO sensors is expected to enable identification of the leakage location if used as a point-wise instrumentation and to greatly reduce the total cost, making the system simple, light, and effective. For further study, more tests will be performed to evaluate the sensitivity of key parameters under various conditions.

목재 섬유판의 음향방출 위치표정과 재료 특성 평가 (Acoustic Emission Source Location and Material Characterization Evaluation of Fiberboards)

  • 노승남;박익근;서성원;김용권
    • 한국공작기계학회논문집
    • /
    • 제14권3호
    • /
    • pp.96-102
    • /
    • 2005
  • Acoustic Emission(AE) technique has been applied to not only material characterization evaluation but also on-line monitoring of the structural integrity. The AE source location technique is very important to identify the source, such as crack, leak detection. Since the AE waveforms obtained from sensors are very difficult to distinguish the defect signals, therefore, it is necessary to consider the signal analysis of the transient wave-form. In this study, we have divided the region of interest into a set finite elements, and calculated the arrival time differences between sensors by using the velocities at every degree from 0 to 90. A new technique for the source location of acoustic emission in fiberboard plates has been studied by introducing Wavelet Transform(WT) do-noising technique. WT is a powerful tool for processing transient signals with temporally varying spectra. If the WT de-noising was employed, we could successfully filter out the errors of source location in fiberboard plates by arrival time difference method. The accuracy of source location appeared to be significantly improved.

스마트 가스 계량기 압력 데이터 기반 누출 판단 기법 개발 (Development of Leakage Judgment Technique based on Pressure Data of Smart Gas Meter)

  • 김정훈;오정석;이진한
    • 한국가스학회지
    • /
    • 제27권2호
    • /
    • pp.57-64
    • /
    • 2023
  • 가스계량기의 검침방식이 발전하면서 원격검침이 가능한 스마트 가스 계량기(누출점검용 계량기 및 다기능 안전 계량기)가 사용되고 있다. 이러한 계량기는 부가기능으로 수집하는 유량 및 압력 데이터를 활용하여 누출 판단을 하는 기능이 있다. 유량 데이터를 이용한 누출판단 기능은 실제 현장에서 유효한 사례가 있지만 압력 데이터 기반 누출 판단 기준은 누출로 인한 압력 값 변화뿐만 아니라 여러 요인(정압기 압력 크기, 인접 계량기 연계, 인접 주택 사용량, 계량기 위치 등)으로 압력 크기 변화(레벨)가 있는 문제점이 있다. 본 논문에서는 스마트 가스계량기에서 수집되는 압력데이터를 활용하여 누출여부를 판단 할 수 있는 기법으로 압력 데이터 전처리 방법과 누출 여부 관련 압력 값 범위 기준, 누출판단 기법 및 적용 사례 검증을 통해 개발하였다.

전철 간섭 대책용 분포형 외부전원시스템의 양극위치 (Anode Location of Distributed ICCP Systems for Mitigation of DC Traction Interference on Buried Pipelines)

  • 이현구;하태현;하윤철;배정효;김대경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1660-1662
    • /
    • 2005
  • When an underground pipeline runs parallel with DC traction systems, it suffers from DC traction interference. Because the train is fed by the substation through the overhead wire and return current back to the substation via the rails. If these return rails are poorly insulated from earth, DC current leak into the earth and can be picked up by nearby pipeline. It may bring about large-scale accidents even in cathodically protected systems. In this paper we analyze the anode location of distributed impressed current cathodic protection systems for the mitigation of DC traction interference on buried pipelines using the simulation software CatPro. We can get a fix on the anode location.

  • PDF

시간영역반사계를 이용한 해수배관시스템의 누수 탐지용 센서 개발 연구 (Development of TDR-based Water Leak Detection Sensor for Seawater Pipeline of Ship)

  • 황현규;신동호;김헌희;이정형
    • 해양환경안전학회지
    • /
    • 제28권6호
    • /
    • pp.1044-1053
    • /
    • 2022
  • 시간영역반사계(TDR)는 케이블의 물리적 결함을 검사하는 기법이며 누수 탐지 분야로의 응용영역을 확대하고 있다. 본 연구는 시간영역반사계 기법을 활용하여 선박 기관실 해수 배관의 누설 감지용 케이블형 센서를 개발하였다. 케이블 센서의 형상은 꼬임형상과 흡습부재를 이용하여 제작하였으며 개발된 센서의 누수 감지 여부와 위치 탐지 가능성을 확인하였다. 개발된 센서는 실제 배관 시험 장치에 부착하여 평가하였으며 해수 누설에 따른 다양한 TDR 신호를 취득하였다. 센서는 꼬임횟수, 피복 두께를 변수로 하여 제작하였으며 TDR 신호에 미치는 효과를 분석하였다. 실험 결과, 꼬임형 센서는 평행한 띠 형상의 센서에 비해 평활한 신호 취득이 가능하였으며 최적 꼬임 횟수는 단위길이 당 10회 이상인 것으로 나타났다. 절연 피복두께의 경우 적정 민감도 확보가 가능한 절연 피복부재의 두께는 도선직경의 80%~120%로 확인되었다. 누수 위치 추정을 위해 회귀분석 실시 결과, 결정계수는 0.9998로 실제 누설 위치와 높은 상관관계를 나타내었다. 결과적으로 제안된 TDR 기반의 누수 감지용 꼬임형 센서는 해수 배관 시스템의 누수 감시 센서로의 충분한 적용성을 확인하였다.