• Title/Summary/Keyword: Leak late

Search Result 24, Processing Time 0.016 seconds

Extubation Time by Birth Weight and the Predictors for Success/Failure at the First Extubation in Extremely Low Birth Weight Infants (초극소저출생체중아에서 출생체중별 발관시기 및 첫 발관 시의 성공/실패 예측인자)

  • Choi, Chang Won;Park, Sung Eun;Jeon, Ga Won;Yoo, Eun Jung;Hwang, Jong Hee;Chang, Yun Sil;Park, Won Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.5
    • /
    • pp.488-494
    • /
    • 2005
  • Purpose : To outline the aspects of extubation by birth weight and find the predictors for success/failure at the first extubation in extremely low birth weight infants. Methods : One hundred thirteen extremely low birth weight infants(<1,000 g) who were admitted to NICU at Samsung Seoul Hospital between Jan. 2000 and Jun. 2004 were enrolled. Clinical characteristics that are thought to be related with extubation success or failure were compared with the success and the failure of the first extubation. Results : As the birth weight decreased, extubation success day was significantly delayed : $16{\pm}3day(d)$ in 900-999 g; $20{\pm}3d$ in 800-899 g; $35{\pm}4d$ in 700-799 g; $37{\pm}9d$ in 600-699 g; $49{\pm}12d$ in ${\leq}599g$. 25 out of 113 infants(22%) failed the first extubation. Preterm premature rupture of membrane was associated with extubation success, and air leak was associated with extubation failure, with a borderline significance. Postnatal and corrected age and body weight at the first extubation, nutritional status, and ventilator settings were not associated with extubation success or failure. Extubation success day was significantly delayed, and the incidence of late-onset sepsis and mortality was significant higher in the failure of the first extubation. Conclusion : We could not find significant predictors for success/failure at the first extubation. The failure of the first extubation had an increased risk of late-onset sepsis and death. Further studies are needed to find the predictors for extubation success/failure.

Clinical Results of Aortic Valve Replacement (대동맥판 치환술의 임상 성적)

  • Na, Guk-Ju;O, Jeong-U;An, Byeong-Hui;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.152-157
    • /
    • 1997
  • From August 1986 until June 1995, single aortic valve replacement was performed in 65 patients at the Chonnam National University Hospital. worthy-eight were male and 17 were female patients, ranging from 19 to 68 years of age(median : 43 years). The causes of the valve lesions were rheumatic in 29 patients (44.6%), bicuspid aortic valve in 6 patients (6.2%), endocarditis in 6 patients(6.2%), unknown in others. Concomitant surgical procedures were performed in 10 patients : repair of congenital defect in 5, pericardiectomy in 1, coronary artery bypass grafting in 1, noncoronary sinus plication in 1, Valsalva sinus aneurysmectomy in 1, subaortic membrane resection in 1 Used valves were 51. Jude-Medical valve in 42, Duromedics valve in 22, Bjork-Shiley valve in 2, Carpentier-Edward valve in 1. There were 3 hospital deaths (4.6%), and 2 late deaths (3.2%). Follow-up was 95.2% complete. The 10-year acturlal survival rate was 85.3%. Postoperative complications were low cardiac utput in 8, arrythmia in 5, valve related hemolysis in 1, cerebral infarction in 1, and gastrointestinal bleeding in 2. Reoperation was performed in 4 for surgical bleeding, in 3 for paravalvular leak. The mean improvement in New York Heart Association functional class is from 2.79 $\pm$ 0.66 preoperatively to 1.25 $\pm$ 0.49 postoperatively(p < 0.001) The change of cardiothoracic ratio from preoperative to postoperative is 0.57 $\pm$ 0.06 to 0.54 $\pm$ 0.05 (p < 0.05). The left ventricular ejection fraction change is not significant perioperatively. There are no mechanical failures. This early and intermediate-term follow-up suggests that in adults in whom valve repair is not possible, the mechanical valve is a reliable and durable prosthesis with good hemodynamic function and a low rate of thromboembolic event.

  • PDF

Surgical Treatment of the Congenital Esophageal Atresia (선천성 식도 폐쇄증의 외과적 치료)

  • 최필조;전희재;이용훈;조광조;성시찬;우종수
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.567-572
    • /
    • 1999
  • Background: Surgical correction of the full spectrum of esophageal atresia with tracheoesophageal fistula has improved over the years, but the mortality and morbidity assoiated with repair of these anomalies still remains high. Material and Method: We retrospectively analyzes 27 surgically treated patients with esophageal atresia and tracheoesophageal fistula at Dong-A University Hospital between January 1992 and March 1997. Result: There were 21 male and 6 female patients. Mean birth weight was 2.62$\pm$.385 kg(2.0~3.4 kg). Twenty- four(88.9%) had esophageal atresia with distal tracheoesophageal fistula, and 3(11.1%) had pure esophageal atresia. Four(14.8%) infants were allocated to Waterston risk group A, 18(66.7%) to group B, and 5(18.5%) to group C. In eighteen(66.7%) infants with associated anomalies, cardiovascular anomalies were the most common. Three had a gap length of 3.5 cm or greater(ultra-long gap) between esophageal segments, 7 had 2.0 to 3.5 cm(long gap), 8 had 1.0 to 2.0 cm(medium gap), and 9 had 1 cm or less(short gap) gap length. Among 27 neonates, 3 cases underwent staged operation, late colon interposition was done in 2, and all other 24 cases underwent primary esophageal anastomosis. Oerative mortality was 2/27(7.4%). Causes of death included acute renal failure(n=1), empyema from anastomotic leak(n=1), necrotizing enterocolitis(n=1), sepsis(n=1), insulin-dependent diabetus mellitus(n=1 . There were 4 anastomosis- related complications including stricture in 3, leakage in 1. Mortality was related to the gap length(p<.05). Conclusion: Although the complication rate associated with surgical repair of these anomalies is high, this does not always implicate the operative mortality. The overall survival can be improved by effective treatment for combined anomalies and intensive postoperatve care.

  • PDF

Reoperations on the Aortic Root and Ascending Aorta (대동맥근부 혹은 상행대동맥의 재수술)

  • Baek, Man-Jong;Na, Chan-Young;Kim, Woong-Han;Oh, Sam-Se;Kim, Soo-Cheol;Lim, Cheong;Ryu, Jae-Wook;Kong, Joon-Hyuk;Kim, Wook-Sung;Lee, Young-Tak;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.35 no.3
    • /
    • pp.188-198
    • /
    • 2002
  • Background: Reoperations on the aortic root or the ascending aorta are being performed with increasing frequency and remain a challenging problem. This study was performed to analyze the results of reoperations on the ascending aorta and aortic root. Material and Method: Between May 1995 and April 2001, 30 patients had reoperations on the ascending aorta and aortic root and were reviewed retrospectively. The mean interval between the previous repair and the actual reoperation was 56 months(range 3 to 142 months). Seven patients(23.3%) had two or more previous operations. The indications for reoperations were true aneurysm in 7 patients(23.3%), prosthetic valve endocarditis in 6(20%), false aneurysm in 5(16.7%), paravalvular leak associated with Behcet's disease in 4(13.3%), malfunction of prosthetic aortic valve in 4(13.3%), aortic dissection in 3(10%), and annuloaortic ectasia in 1(3.3%). The principal reoperations performed were aortic root replacement in 17 patients(56.7%), replacement of the ascending aorta in 8(26.7%), aortic and mitral valve replacement with reconstruction of fibrous trigone in 2(6.6%), patch aortoplasty in 2(6.6%), and aortic valve replacement after Bentall operation in 1 (3.3%). The cardiopulmonary bypass was started before sternotomy in 7 patients and the hypothermic circulatory arrest was used in 16(53.3%). The mean time of circulatory arrest, total bypass, and aortic crossclamp were 20$\pm$ 12 minutes, 228$\pm$56 minutes, and 143$\pm$62 minutes, respectively Result: There were three early deaths(10%). The postoperative complications were reoperation for bleeding in 7 patients(23.3%), cardiac complications in 5(16.7%), transient acute renal failure in 2(6.6%), transient focal seizure in 2(6.6%), and the others in 5. The mean follow-up was 22.8 $\pm$20.5 months. There were two late deaths(7.4%). The actuarial survival was 92.6$\pm$5.0% at 6 years. One patient required reoperation for complication of reoperation on the ascending aorta and aortic root(3.7%). The 1- and 6-year actuarial freedom from reoperation was 100% and 83.3$\pm$15.2%, respectively. One patient with Behcet's disease are waiting for reoperation due to false aneurysm, which developed after aortic root replacement with homograft. There were no thromboembolisms or anticoagulant related complications. Conclusions: This study suggests that reoperations on the ascending aorta and aortic root can be performed with acceptable early mortality and morbidity, and adequate surgical strategies according to the pathologi conditions are critical to the prevention of the reoperation.