• 제목/요약/키워드: Leak Noise

검색결과 79건 처리시간 0.021초

발전용 증기밸브 누설량 평가에 관한 연구 (Study on Evaluation of the Leak Rate for Steam Valve in Power Plant)

  • 이상국;박종혁;유근배
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

지하매설 배관의 누수지점 탐지를 위한 음향학적 해석 및 신호처리 (Acoustical analysis and signal processing for leak location of buried pipes)

  • 이영섭;윤동진;백광현;김상무
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2004년도 춘계학술발표대회 논문집 제23권 1호
    • /
    • pp.225-230
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband noise from a leak location and can be propagated to both directions of water pipes. However, the necessity of long-range detect ion of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretical analyzed and the wave velocity was confirmed with experiment The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detect ion for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

SNR Improvement of AE Signal for Detection of Gas Leak from Tubes under Vibratory Environment

  • Lee, Tae-Hun;Jhang, Kyung-Young;Kim, Jung-Kyu
    • 비파괴검사학회지
    • /
    • 제27권3호
    • /
    • pp.262-267
    • /
    • 2007
  • Detection of gas leak from a tube is a very important issue in the quality control of machines such as the heat exchanger of an air-conditioner, because leakage of operating gas directly reduces the performance of machines. The acoustic emission (AE) method is a common way to detect leak of gas, however its application under the environment of mechanical vibration is restricted since most AE detectors are very sensitive to external vibration noise. In order to overcome this problem, we propose a method based on the mode analysis of the Lamb wave. In this method, the dominant Lamb mode and its frequency are found first, and then a proper band-pass filter is used to retain only this frequency component. In this way, we could improve the SNR (signal-to-noise ratio) of AE signal generated by gas leak from the tube even under vibratory environment.

음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구 (In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.315-322
    • /
    • 2008
  • 발전소 밸브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 밸브 시트(seat)면의 이물질 삽입, 시트의 균열, 스템(stem) 패킹(parking) 또는 용접부위 결함 및 피로균열 둥에 의해 누설손상이 발생하고 있다. 이러한 밸브 내부누설 상태를 정밀하게 진단하고 평가하기 위해서는 음향방출기술의 적용이 필요하며, 본 논문은 현장적용이 가능한 연구를 수행하고 그 결과를 소개하고자 한다. 또한 실제 발전소에서 운전되는 다양한 밸브 조건을 토대로 실험실 실험에 의해 주변잡음, 밸브누설시의 음향레벨 및 스펙트럼 특성을 분석하고, 발전소 현장실험 결과와의 비교분석을 통하여, 밸브 누설상태에 따른 주변잡음, 음향신호 및 측정 가능한 최소 누설검출량 등의 평가방법에 대해 고찰하였다. 실험실 실험 및 현장적용 연구결과로부터 밸브누설 여부를 포함한 상태 평가와 최소 측정가능 누설검출량 평가가 가능하였으며, 향후 본 연구는 발전설비 안전운전과 밸브누설로 인한 에너지 손실 예방에 크게 기여할 것으로 기대된다.

지하매설 플라스틱 배관의 누수지점 추정을 위한 창함수 비교 연구 (Comparison of Window Functions for the Estimation of Leak Location for Underground Plastic Pipes)

  • 이영섭
    • 한국소음진동공학회논문집
    • /
    • 제20권6호
    • /
    • pp.568-576
    • /
    • 2010
  • It is widely known that the leak locating of underground plastic pipelines is much more difficult than that of cast iron pipelines. The precision of the leak locating depends upon the speed of leak signal and the time delay estimation between the two sensors on the pipeline. In this paper, six different windowing filters are considered to improve the time delay estimation especially for the plastic pipelines. The time delay is usually estimated from the peak time of cross-correlation functions. The filtering windows including rectangle, Roth, Wiener, SCOT, PHAT and maximum likelihood are applied to derive the generalized cross-correlation function and compared each other. Experimental results for the actual plastic underground water supply pipeline show that the introduction of the filtering windows improved the precision of time delay estimation. Some window functions provide excellent leak locating capability for the plastic pipe of 98 m long, which is less than 1 % of the pipe lengths. Also a new probabilistic approach that the combinations of all results from each filtering window is suggested for the better leak locating.

열상장비용 스터링 극저온 냉동기 특성평가 (IV) : 진동, 소음, 누설시험 (The performance evaluation of Stirling cryocooler for thermal imaging system (IV) : Vibration, Noise, Leak test)

  • 박성제;홍용주;김효봉;김양훈;최상규;나종문
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.167-170
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. A free piston and free displacer(FPFD) Stilting cryocooler for cooling infrared and cryo-sensors is currently under development at KIMM. Our coolers are specifically designed to work in the thermal imaging device and to meet requirements such as cooling capacity, COP and high reliability. In this work, Stilting cryocooler is designed, manufactured and fabricated, and performance characteristics for the vibration, acoustic noise, EMI and leak rate are evaluated. Vibration outputs are measured to 20KHz for compressor and expander, respectively. And, the objective of noise test is a noise level, less than 30㏈ at 5 m. EMI tests are carried out according to the standard MIL-STD-461C tests RE01 and RE02. Leak test for the Stilting cryocooler is performed by bombing method.

  • PDF

배관-유체 연성진동을 이용한 누수지점 탐지 알고리듬 개발 연구 (An Algorithm for Leak Locating using Coupled Vibration of Pipe-Fluid)

  • 이영섭;윤동진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.798-803
    • /
    • 2004
  • Leak noise is a good source to identify the exact location of a leak point of underground water pipelines. Water leak generates broadband sound from a leak location and this sound propagation due to leak in water pipelines is not a non-dispersive wave any more because of the surrounding pipes and soil. However, the necessity of long-range detection of this leak location makes to identify low-frequency acoustic waves rather than high frequency ones. Acoustic wave propagation coupled with surrounding boundaries including cast iron pipes is theoretically analyzed and the wave velocity was confirmed with experiment. The leak locations were identified both by the acoustic emission (AE) method and the cross-correlation method. In a short-range distance, both the AE method and cross-correlation method are effective to detect leak position. However, the detection for a long-range distance required a lower frequency range accelerometers only because higher frequency waves were attenuated very quickly with the increase of propagation paths. Two algorithms for the cross-correlation function were suggested, and a long-range detection has been achieved at real underground water pipelines longer than 300m.

  • PDF

음향방출법에 의한 발전용 밸브 누설평가 (The Evaluation of Internal Leak in Valve for Power Plant Using Acoustic Emission Method)

  • 이상국;이선기;이준신;이욱륜
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1733-1739
    • /
    • 2004
  • The objective this study is to estimate the feasibility of acoustic emission method for the internal leak from the valves in nuclear power plants. From the experimental results, it was suggested that the acoustic emission method for monitoring of leak was feasible. When the background levels are higher than the acoustic signals from leak, we can detect the leak analyzing the spectrum of the remainders which take the background noise from the acoustic signals.

  • PDF

음향방출 계측에 의한 터빈 제어밸브 내부누설 평가연구 (Study on Evaluation of Internal Leak of Turbine Control Valve in Power Plant Using Acoustic Emission Signal Measurement)

  • 이상국
    • 동력기계공학회지
    • /
    • 제12권5호
    • /
    • pp.65-70
    • /
    • 2008
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the turbine major valves relating to safety for turbine operating and prevention of turbine trouble at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized electro-hydraulic control oil flowed through turbine electro-hydraulic controller oil check valve and turbine power/trip fluid solenoid valve in the condition of actual turbine operating. The acoustic emission method was applied to the valves at the site, and the background noise was measured far the abnormal plant condition. To judge for the leak existence ell the object valves, voltage analysis and frequency analysis of acoustic signal emitted from infernal leak in the valve operating condition are performed. It was conformed that acoustic emission method could monitor for valve internal leak to high sensitivity.

  • PDF

발전용 밸브누설 실시간 감시기술 연구 (Study on the Real-Time Leak Monitoring Technique for Power Plant Valves)

  • 이상국
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.39-44
    • /
    • 2007
  • The purpose of this study is to verify availability of the acoustic emission in-situ monitoring method to the internal leak and operating conditions of the major valves at nuclear power plants. In this study, acoustic emission tests are performed when the pressurized temperature water and steam flowed through glove valve(main steam dump valve) and check valve(main steam outlet pump check valve) on the normal size of 12 and 18". The valve internal leak monitoring system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, frequency analysis, voltage analysis and amplitude analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF