• 제목/요약/키워드: Lead cross sections

검색결과 34건 처리시간 0.023초

THE MICROSTRUCTURE OF Pb-DOPED SOLIDIFIED WASTE FORMS USING PORTLAND CEMENT AND CALCITE

  • Yoo, Hee-Chan;Lee, Dong-Jin
    • Environmental Engineering Research
    • /
    • 제11권1호
    • /
    • pp.54-61
    • /
    • 2006
  • An electron probe microanalysis (EPMA) investigation can provide quantitative and qualitative insight into the nature of the surface and bulk chemistry on solidified waste forms(SWF). The proportion of Pb in grain areas is below 0.3 wt. %, and the proportion near the border of the grain slightly increases to 0.98 wt. % but in the inter-particle areas farther from the grain, the concentration of Pb markedly increases. It is apparent that very little Pb diffuses into the tricalcium silicate($C_3S$) particles and most of the Pb exists as precipitates of sulfate, hydroxide, and carbonate in the cavity areas between $C_3S$ grains. Calcite additions on Pb-doped SWF are also observed to induce deeper incorporation of lead into the cement grains with EPMA line-analysis of cross-sections of cement grains. The line-analysis reveals the presence of $0.2{\sim}5$ weight % Pb over $5\;{\mu}m$ from cement grain boundaries. In the inter-particle areas, the ratio of Ca, Si, Al and S to Pb is relatively similar even at some distance from the grain border and the Pb (wt. %) ratio is reasonably constant throughout the whole inter-particles area. It is apparent that the enhanced development of C-S-H on addition of calcite can increasingly absorbs lead species within the silica matrix.

Inelastic lateral-distortional buckling of continuously restrained rolled I-beams

  • Lee, Dong-Sik;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제2권4호
    • /
    • pp.297-314
    • /
    • 2002
  • An energy method of analysis is presented which can be used to study the inelastic lateral-distortional buckling of hot-rolled I-sections continuously restrained at the level of the tension flange. The numerical modelling leads to the incremental and iterative solution of a fourth-order eigenproblem, with very rapid solutions being obtainable, so as to enable a study of the factors that influence the strength of continuously restained I-beams to be made. Although hot-rolled I-sections generally have stocky webs and are not susceptible to reductions in their overall buckling loads as a result of cross-sectional distortion, the effect of elastic restraints, particularly against twist rotation, can lead to buckling modes in which the effect of distortion is quite severe. While the phenomenon has been studied previously for elastic lateral-distortional buckling, it is extended in this paper to include the constitutive relationship characteristics of mild steel, and incorporates both the so-called 'polynomial' and 'simplified' models of residual stresses. The method is validated against inelastic lateral-torsional buckling solutions reported in previous studies, and is applied to illustrate some inelastic buckling problems. It is noted that over a certain range of member slenderness the provisions of the Australian AS4100 steel standard are unconservative.

-중성자 TOF법에 의한 $^{99}Tc$의 에너지의존 중성자 포획단면적측정- (Measurement of the Energy-Dependent Neutron Capture Cross Section of $^{99}Tc$ by Using the Neutron TOF Method)

  • 윤정란;이상복;이준행;이삼열
    • 한국콘텐츠학회논문지
    • /
    • 제5권5호
    • /
    • pp.133-139
    • /
    • 2005
  • 교토대학 원자로실험소의 46-MeV 전자선형가속구를 이용하여 $^{99}Tc$의 중성자포획단면적을 중성자에너지 0.007 eV에서 47 keV에 걸쳐 중성자 비행시간법을 이용하여 측정을 하였다. 이 중성자포획 결과는 $^{10}B(n,\gamma)$반응의 중성자 반응 단면적에 상대적으로 얻어졌다. 얻어진 결과를 확인하기 위해서 교토대학 원자로실험소의 납감속장치를 이용한 결과를 확인하였다. TOF방법으로 얻어진 결과는 0.0253 eV에서의 결과(20.01 b)에 규격화되었다. 기존의 실험결과들과 평가결과들인 ENDF/B-VI, JENDL-3.2, and JEF-2.2은 본 연구에서 TOF와 납감속장치로 얻어진 결과들과 비교 및 검토하였다.

  • PDF

Fast Neutron Dosimetry with Two Threshold Detectors in Criticality Accidents of Nuclear Reactors

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • 제2권2호
    • /
    • pp.85-95
    • /
    • 1970
  • 두개의 threshold detector로서 인자로의 폭발사고시에 방출되는 속 중성자의 속도분포를 측정하고 그로부터 속 중성자의 인체흡수선량을 계산하였다. 이때 속 중성자의 속도분포는 하나의 스펙트럼 매개변수에 의하여 결정된다는 가정으로부터 얻어지는데 이 매개변수는 threshold detector의 반응율을 측정하므로서 구해진다. 속 중성자의 인체흡수선량은 속 중성자의 속도분포 변화에 따라 큰 변동이 없었으나 threshold detector의 평균반응단면적은 크게 변하였다. 따라서 속 중성자의 속도분포에 관계없이 threshold detector의 평균반응단면적을 고정된 값으로 취하여 속 중성자선량을 계산한다면 큰 오차를 일으키게 될 것이라는 것을 보여주었다. 한편 핵분열에서 방출되는 속 중성자의 속도분포에 대한 세 해석적 표현인 즉 Watt, Cranberg및 Maxwellian 공식들로부터 속 중성자 선량을 계산하여 서로 비교하였다. Watt 및 Cranberg 공식들로 부터 얻어진 속 중성자선량은 Maxwellian 공식으로부터 얻어진 그것보다 약간 높은 값을 보여 주었으며 Watt 공식에 의한 선량계산치는 Cranberg 공식에 의한 그것과 비슷한 값을 보여주었다.

  • PDF

Buckling analysis of complex structures with refined model built of frame and shell finite elements

  • Hajdo, Emina;Ibrahimbegovic, Adnan;Dolarevic, Samir
    • Coupled systems mechanics
    • /
    • 제9권1호
    • /
    • pp.29-46
    • /
    • 2020
  • In this paper we deal with stability problems of any complex structure that can be modeled by beam and shell finite elements. We use for illustration the steel plate girders, which are used in bridge construction, and in industrial halls or building construction. Long spans, slender cross sections exposed to heavy loads, are all critical design points engineers must take into account. Knowing the critical load that will cause lateral torsional buckling of the girder, or load that can lead to web buckling, as an important scenario to consider in a design process.Many of such problem, including lateral torsional buckling with influence of lateral supports and their spacing on critical load can be solved by the proposed method. An illustrative study of web buckling also includes effects of position and spacing of transverse and longitudinal web stiffeners, where stiffeners can be modelled optionally using shell or frame elements.

고추잠자리의 精子完成의 電子顯微鏡的 硏究 (An Electron Microscopy of Spermiogenesis in the Dragonfly, Crocothemis servilia Drury)

  • 백경기;최춘근;이국범
    • 한국동물학회지
    • /
    • 제15권3호
    • /
    • pp.133-147
    • /
    • 1972
  • 고추잠자리(Crocothemis servilia Drury)의 精子完成過程을 究明하기 爲하여, 本 硏究에 着手한 바, 다른 無脊椎動物의 精子完成過程에서 이미 밝혀진 構造들과 比較해 가면서 特殊한 分化相을 觀察한 結果, 첫째 核의 染色質이 漸次 濃縮되기 始作함에 따라서 核의 모양도 球形에서 楕圓形으로, 楕圓形에서 圓錐形으로 變하였으며 둘째로 核이 細胞의 一極端으로 移動하고 核의 尾部가 陷入되며 셋째 中心粒이 核 陷入 部位에 位置하여 여기에서부터 軸 가 形成된다. 넷째는 골지體에서 起因된 尖體顆粒은 核의 先端으로 移動되어 결국 尖體를 形成하게 된다.

  • PDF

논우렁이 촉수(觸手) 수축근(收縮筋)의 미세구조(微細構造) (An Ultrastructural Study of Tentacular Retractor Muscle of Chinese Mystery Snail, Cipangopaludina chinensis malleata Reeve)

  • 송용직;김우갑;김창환
    • Applied Microscopy
    • /
    • 제17권2호
    • /
    • pp.31-40
    • /
    • 1987
  • The tentacular retractor muscle has many arrays of muscle fiber bundles under the epithelial layer. Most of muscle fiber bundles are arranged in parallel to the longitudinal axes of muscle fibers and a small number of them perpendiculary to them. These smooth muscle cells are filled with compactly arranged myosins and actins. These microfilaments, when the tentacle is protracted, keep abreast with straight for-ward-lined shapes while these microfilaments, when it is retracted, with curved shapes. The foldings in the sarcolemma of the muscle cell, when the tentacle is retracted, lead to the formation of normal subsurface tubules along with which a few mitochondria are included. It is thought that the formation of the sarcolemmal differentiation like the subsurface tubules has a close relation with the protraction and retraction of the tentacle. Mitochondria are found throughout the muscle cell, and sarcoplasmic reticulum (SR) developed greatly in the exoplasm close to the sarcolemma and associated with the cell membrane. Dense bodies are distributed irregularly and thin filaments are scattered around the thick filament in cross-sections, but the thin filaments may be arranged in complete or partial orbits around thick filaments. Complete orbits are infrequent.

  • PDF

고온고습 전원인가 시험에서 Cl에 의한 이온 마이그레이션 불량 (Chlorine effect on ion migration for PCBs under temperature-humidity bias test)

  • 허석환;신안섭
    • Journal of Welding and Joining
    • /
    • 제33권3호
    • /
    • pp.47-53
    • /
    • 2015
  • By the trends of electronic package to be more integrative, the fine Cu trace pitch of organic PCB is required to be a robust design. In this study, the short circuit failure mechanism of PCB with a Cl element under the Temperature humidity bias test ($85^{\circ}C$/85%RH/3.5V) was examined by micro-structural study. A focused ion beam (FIB) and an electron probe micro analysis (EPMA) were used to polish the cross sections to reveal details of the microstructure of the failure mode. It is found that $CuCl_x$ were formed and grown on Cu trace during the $170^{\circ}C$/3hrs and that $CuCl_x$ was decomposed into Cu dendrite and $Cl_2$ gas during the $85^{\circ}C$/85%RH/3.5V. It is suggested that Cu dendrites formed on Cu trace lead to a short circuit failure between a pair of Cu traces.

Flow Dynamics Near End-To-End Anastomoses - Part I. In Vitro Compliance Measurement -

  • Kim, Y.H
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권2호
    • /
    • pp.165-174
    • /
    • 1992
  • Compliance mismatch across an end-to-end anastomosis was measured In the In vitro experimental setup. A 35mm camera was used and Image process was done in Gould/ DeAnza Image processor. The results showed that compliances of Penrose tubing and synthetic PTFE grafts were In good agreement with the previously reported In vivo data. PTFE grafts exhibited a nonlinear behavior with compliance decreasing with Increasing transmural pressure, whereas the compliance of the Penrose tubing remained relatively constant within the range of the pressures in which data were obtained. The lumen cross sections at the anastomosis were affected by the suture and the mismatch In compliance between the Penrose tubing and vascular grafts. The varla~lons In the lumen dtameter at the anastomosis was more pronounced with increasing transmural pressures. From the present study, it was clearly demonstrated that the compliance of prosthetic grafts Is much lower than that of the arteries. In addition to the hemodynamlc consequences, compliance mismatch across the anastomosis has been known to lead to Increased anastomotlc and suture stresses with resultant suture line dehlscence and false aneurysm formation. Thus, there are good hemodynamic reasons to suppose that Introduction of a less compliant arterial graft Into the arterial circulation wlll be damaging and that grafts should be made to match the elastic behavior of their host arteries as closely possible.

  • PDF

An optimization framework for curvilinearly stiffened composite pressure vessels and pipes

  • Singh, Karanpreet;Zhao, Wei;Kapania, Rakesh K.
    • Advances in Computational Design
    • /
    • 제6권1호
    • /
    • pp.15-30
    • /
    • 2021
  • With improvement in innovative manufacturing technologies, it became possible to fabricate any complex shaped structural design for practical applications. This allows for the fabrication of curvilinearly stiffened pressure vessels and pipes. Compared to straight stiffeners, curvilinear stiffeners have shown to have better structural performance and weight savings under certain loading conditions. In this paper, an optimization framework for designing curvilinearly stiffened composite pressure vessels and pipes is presented. NURBS are utilized to define curvilinear stiffeners over the surface of the pipe. An integrated tool using Python, Rhinoceros 3D, MSC.PATRAN and MSC.NASTRAN is implemented for performing the optimization. Rhinoceros 3D is used for creating the geometry, which later is exported to MSC.PATRAN for finite element model generation. Finally, MSC.NASTRAN is used for structural analysis. A Bi-Level Programming (BLP) optimization technique, consisting of Particle Swarm Optimization (PSO) and Gradient-Based Optimization (GBO), is used to find optimal locations of stiffeners, geometric dimensions for stiffener cross-sections and layer thickness for the composite skin. A cylindrical pipe stiffened by orthogonal and curvilinear stiffeners under torsional and bending load cases is studied. It is seen that curvilinear stiffeners can lead to a potential 10.8% weight saving in the structure as compared to the case of using straight stiffeners.