• Title/Summary/Keyword: Lead battery plant

Search Result 16, Processing Time 0.02 seconds

Economic Evaluation of Liquid Air Energy Storage (LAES) System (액화 공기 에너지 저장 기술(LAES)의 경제성 분석)

  • Ko, Areum;Park, Sung-Ho;Ryu, Ju-Yeol;Park, Jong-Po
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • Liquid air energy storage (LAES) using gas liquefaction has attracted considerable attention because of its mature technology, high energy density, few geographical constraints, and long life span. On the other hand, LAES has not yet been commercialized and is being developed recently. Therefore, few studies have performed an economic analysis of LAES. In this study, the levelized cost of electricity was calculated and compared with that of other energy storage systems. As a result, the levelized cost of electricity of LAES was $371/MWh. This is approximately $292/MWh, $159/MWh, $118/MWh, and $3/MWh less than that of the LiCd battery, VRFB battery, Lead-acid battery, and NaS battery. In addition, the cost was approximately $62/MWh and $195/MWh more than that of Fe-Cr flow battery and PHS. Sensitivity analysis of the levelized cost of electricity according to the main economic factors was performed, and economic uncertainty analysis was performed through a Monte-Carlo simulation. The cumulative probability curve showed the levelized cost of electricity of LAES, reflecting price fluctuations in the air compressor cost, electricity cost, and standing reserve hourly fee.

C-rate based electrical characteristics and equivalent circuit modeling of 18650 cylindrical Li-ion battery for nuclear power plant application (원전 비상전원 적용성 판단을 위한 다양한 C-rate 기반 원통형 리튬이온 배터리의 전기적 특성분석 및 모델링)

  • Kim, Gunwoo;Park, Seongyun;Park, Jinhyeong;Kim, Jonghoon;Park, Sungbaek;Kim, Youngmi
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.667-674
    • /
    • 2019
  • The recent incidents of Nuclear Power Plant(NPP) gave rise to a total power outage caused by the loss of the functions of the off-site and the emergency power supply. Currently, emergency power supply of NPP have been taken into account by Li-ion batteries instead of existing lead-acid batteries. In order to judge the applicability of the cylindrical Li-ion battery, it is necessary to analysis the results of various electrical tests. This paper investigates the basic electrical characteristics test of three types of cylindrical batteries in order to select the most suitable battery and estimate state of battery through equivalent circuit model and propose method to solve the problem.

Potential Biases Arising in the Use of Cascade Impactors to Estimate Respiratory Tract Deposition Patterns of Lead-Acid Battery Plant Aerosols

  • Hodgkins Douglas G.;Robins Thomas G.;Hinkamp David L.;Levine Steven P.;Schork M. Anthony;Krebs William H.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02a
    • /
    • pp.585-595
    • /
    • 1994
  • The region of the respiratory tract where inhaled particles deposit can have important implications for the causation of local or systemic toxic effects. For most aerosols of occupational importance, respiratory tract deposition can be predicted from the aerodynamic diameter of the particles. With the advent of cascade impactors, particularly those of personal sampler size, the determination of the aerodynamic diameters of aerosols has become more common. Some limitations of cascade impactor use are well recognized (e.g., particle bounce and substrate overloading) and are generally correctable. However, two important limitations of the instruments may not be receiving adequate attention: relative humidity effects on potentially hygroscopic aerosols and the collection characteristics of fibrous aerosols as compared to their actual deposition site potential. The results of this study, when compared to results of previous controlled laboratory trials, suggest that, while potentially hygroscopic lead aerosols from lead acid battery plant operations do not appear to be affected by changes in plant environmental humidity levels, the potential - exists for significant size changes upon inhalation. Secondly, fibers were detected in aerodynamic size ranges that would be associated with deep lung deposition; however, upon microscopic examination, these same fibers would actually be predicted to deposit in the upper airways. This study suggests that the physicalchemical properties and morphological features of an aerosol should be carefully considered by industrial hygienists before cascade impactors are used in attempts to predict the effects of inhaled aerosols.

  • PDF

Optimal Sizing of Distributed Power Generation System based on Renewable Energy Considering Battery Charging Method (배터리 충전방식을 고려한 신재생에너지 기반 분산발전시스템의 용량선정)

  • Kim, Hye Rim;Kim, Tong Seop
    • Plant Journal
    • /
    • v.17 no.3
    • /
    • pp.34-36
    • /
    • 2021
  • The interest in renewable energy-based distributed power generation systems is increasing due to the recognitions of the breakthrough of existing centralized power generation, energy conversion, and environmental problems. In this study, the optimal capacity was selected by simulating a distributed power generation system based on PV and WT using lead acid batteries as the energy storage system. CHP was adopted as the existing power source, and the optimal capacity of the system was derived through MOGA according to the operating modes(full load/part load) of the existing power source. In addition, it was confirmed that the battery life differs when the battery charging method is changed at the same battery capacity. Therefore, for economical and stable power supply and demand, the capacity selection of the distributed generation system considering the battery charging method should be performed.

Low-Voltage-Stress AC-Linked Charge Equalizing System for Series-Connected VRLA Battery Strings

  • Karnjanapiboon, Charnyut;Jirasereeamornkul, Kamon;Monyakul, Veerapol
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.186-196
    • /
    • 2013
  • This paper presents a low voltage-stress AC-linked charge equalizing system for balancing the energy in a serially connected, valve-regulated lead acid battery string using a modular converter that consists of multiple transformers coupled together. Each converter was coupled through an AC-linked bus to increase the overall energy transfer efficiency of the system and to eliminate the problem of the unbalanced charging of batteries. Previous solutions are based on centralized and modularized topologies. A centralized topology requires a redesign of the hardware and related components. It also faces a high voltage stress when the number of batteries is expanded. Modularized solutions use low-voltage-stress, double-stage, DC-linked topologies which leads to poor energy transfer efficiency. The proposed solution uses a low-voltage stress, AC-linked, modularized topology that makes adding more batteries easier. It also has a better energy transfer efficiency. To ensure that the charge equalization system operates smoothly and safely charges batteries, a small intelligent microcontroller was used in the control section. The efficiency of this charge equalization system is 85%, which is 21% better than other low-voltage-stress DC-linked charging techniques. The validity of this approach was confirmed by experimental results.

The Clinical Aspects of Wild Plant Poisoning (야생식물 중독의 임상 양상)

  • Ok, Taek-Gun;Park,, Chan-Woo;Cho, Jun-Hwi;Cheon, Seung-Whan;Lee, Seung-Young;Kim,, Sung-Eun;Choi, Ki-Hoon;Bae, Ji-Hoon;Seo, Jeong-Yeul;Ahn, Hee-Cheol;Ahn, Moo-Eob;Cho, Byung-Ryul;Kim,, Yong-Hoon
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.3 no.2
    • /
    • pp.79-85
    • /
    • 2005
  • Purpose: With the recent boom in 'eating healthy', many adults are interested in dieting to prevent future diseases. However only well trained experts can distinguish between what are edible vegetables and herbs from their poisonous look-alikes. In cases where a patient unknowingly ingests a poisonous herb, is caught off guard by the poisonous side effects that occur because of their lack of knowledge of what they have ingested. This paper will focus on the need to educate the public about the risks involved with ingesting wild vegetables and herbs and study the emergency diagnosis and treatment of poisoned patients that enter the emergency room. Method: This study was done in the spring of 2004 (from March to May) in the Kangwon Young-Seo districts of Korea. 15 subjects used in this study, entered the emergency room showing signs of toxic symptoms. Data was collected by examining subject's records. Additional data was collected by collaborating with physicians in the hospital that diagnosed and treated the subjects. Identifying the poisonous vegetable or herb is the first step to proper diagnosis and treatment. Subjects admitted to the emergency room, underwent a battery of tests: laboratory examination, ECG, radiological exam and etc. Results: The demographics of the study encompassed subjects with the average age of $50{\pm}19$ years old. There were 10 men and 5 women. Common symptoms of this study included; gastrointestinal symptoms such as nausea, vomiting, epigastric pain and so on. In the case of Caltha palustris ingestion, additional symptoms were present; bradycardia and hypotension which lasted for a long time. While cases that ingested Scopolia parviflora had little effect on vital signs but manic episodes lasted for about three days. Veratrum patulum ingestion showed signs of bradycardia and hypotension but contrary to Caltha palustris recovery was shorten by treating with dopamine. However, dizziness, headache and paresthesia of the extremities continued for a long time. Finally Sium ninsi ingestion showed visual disturbance, paresthesia of the extremities, dizziness as their initial symptoms. Conclusion: The risks involved with ingesting wild plants without the proper knowledge can lead to serious side effects and steps need to be taken to educate the public. In addition, all emergency physicians need to have a working knowledge of the symptoms and signs associated with ingesting toxic wild plants and need to treat accordingly.

  • PDF