• 제목/요약/키워드: Lead/Tilt Angle

검색결과 16건 처리시간 0.019초

둔부의 압력분포 비교를 이용한 고령자용 기립보조의자의 기립 최적각도 제안 (A proposal of the Optimal Angle of Standing Assistant Chair for the Elderly by Comparing of Pressure Distribution on Hip)

  • 장성호;백지훈;이중언;;강석완;이왕범
    • 산업경영시스템학회지
    • /
    • 제41권3호
    • /
    • pp.108-114
    • /
    • 2018
  • One of the most performed action in daily life is standing up from sitting position. As the population of the world is aging at the high rates, people may face problems with reduced muscle strength as well as psychological changes. This can lead elderly people having difficulties with standing up from chair. Now, with the aging trend worldwide, products are being developed that can support the lives of the elderly. This study examines the distribution of hip pressure in relation to the seating positions of the standing assistance seats under development to prevent standing up accidents in older adults. The currently developing standing assistant chair designed to tilt to a maximum angle of 25 degrees. At over $25^{\circ}$, design considers that older people are at risk of thrown back out of that force and that the forces exerted on their arms and legs can be a significant burden to older people. By considering danger of higher than $25^{\circ}$ for older people which is experimented in the basis of static capturing approach in previous papers, it is experimented people with age group of 20~60 on $0^{\circ}$ to $25^{\circ}$ tilting angle on the basis of dynamic capturing method in order to pick convenient angle of inclination. Moreover, tried to find the optimum angle by comparing the hip pressure distribution when seated at the edge of the seat and at the center of the seat with the pressure distribution sensor.

The Wetting Properties of UBM-coated Si-wafer to the Lead-free Solders in Si-wafer/Bumps/Glass Flip-Chip Bonding System

  • Hong, Soon-Min;Park, Jae-Yong;Park, Chang-Bae;Jung, Jae-Pil;Kang, Choon-Sik
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2000년도 Proceedings of 5th International Joint Symposium on Microeletronics and Packaging
    • /
    • pp.74-79
    • /
    • 2000
  • In an attempt to estimate the wetting properties of wettable metal layers by wetting balance method, an analysis of wetting curves of the coating layer was performed. Based on the analysis, wetting properties of UBM-coated Si-plate were estimated by the new wettability indices. The wetting curves of the one and both sides-coated UBM layers have the similar shape and show the similar tendency to the temperature. So the wetting property estimation of one side coating is possible with wetting balance method. For UBM of Si-chip, Cr/Cu/Au UBM is better than Ti/Ni/Au in the point of wetting time. At general reflow temperature, the wettability of high melting point solders(Sn-Sb, Sn-Ag) is better than that of few melting point ones(Sn-Bi, Sn-In).The contact angle of the one side coated plate to the solder can be calculated from the farce balance equation by measuring the static state force and the tilt angle.

  • PDF

Iliotibial Band Stretching in the Modified Thomas Test Position Changes Hip Abduction Angle and Vastus Medialis Activity in Individuals With Tight Iliotibial Band

  • Baik, Seung-min;Jeong, Hyo-jung;Lee, Ji-hyun;Park, Dong-hwan;Cynn, Heon-seock
    • 한국전문물리치료학회지
    • /
    • 제26권1호
    • /
    • pp.75-83
    • /
    • 2019
  • Background: A tight iliotibial band (ITB) may lead to lateral patellar maltracking, compression, and tilt, and dominant vatus lateralis (VL) muscle activation relative to vastus medialis oblique (VMO) can laterally displace the patella, which leads to anterior knee pain. Therefore, an effective management technique is needed to stabilize the patella in individuals with tight ITB. Increased stability during the modified Thomas test has the potential to decrease compensatory motion and thus to selectively stretch the ITB. Objects: The purpose of this study was to determine the effects of ITB stretching in the modified Thomas test position on ITB flexibility, patellar translation, and muscle activities of the VMO and VL during quadreceps-setting (QS) exercise in individuals with tight ITB. Methods: Twenty-one subjects with tight ITB were recruited. Digital inclinometer was used to measure the hip adduction angle during the modified Ober test. Universal goniometer was used to measure the hip abduction angle during the modified Thomas test. Ultrasonography was used to measure the patella-condylar distance. Electromyography was performed to collect data of muscle activities. Paired t-test was used to determine the statistical significance between pretest and posttest. Results: The range of hip adduction in modified Ober test increased (p=.04) and the range of hip abduction in the modified Thomas test decreased after ITB stretching (p<.01). There was no difference between lateral patellar translation (p=.18). VMO muscle activity significantly increased after ITB stretching during QS (p<.01). VL muscle activity had no difference after stretching. Conclusion: The ITB stretching in the modified Thomas test position can be suggested as a management method for improving ITB flexibility and VMO muscle activity in individuals with tight ITB.

小規模 太陽熱 給湯시스템 의 最適設計 에 관한 硏究 (A Study on the Optimum Design for a Solar Domestic Hot Water System)

  • 서정일;이영수
    • 대한기계학회논문집
    • /
    • 제8권6호
    • /
    • pp.517-525
    • /
    • 1984
  • 본 연구에서는 2개의 축적탱크와 외부 열교환기로 구성된 가정용 태양열 급탕 시스템을 시뮬레이션 모델로 이론적인 해석을 하고 설계인자들의 값들을 변화시킴으로 써 각각의 성능을 계산할 수 있었다. 또 이 성능 계산치에 의하여 최적설계 인자치 들을 구할 수 있었다. 또한 1983년 1년간 서울지방의 매 시간 일분량과 기온을 사용 하였다.

전자파표면유속계의 측정 각도에 따른 평수기 유속 측정 정확도 분석 (Accuracy evaluation of microwave water surface current meter for measurement angles in middle flow condition)

  • 손근수;김동수;김경동;김종민
    • 한국수자원학회논문집
    • /
    • 제53권1호
    • /
    • pp.15-27
    • /
    • 2020
  • 하천 유량관측은 수자원의 관리를 위해 활용되는 기초적이고 대표적인 자료로 하천에서 정확한 유량을 관측하는 것은 중요하다. 따라서 최근에는 다양한 첨단 장비들이 개발되어 전통적인 하천의 유량관측을 대체하거나 보완하고 있다. 여러 최신 장비들 중 전자파표면유속계는 홍수기와 같이 하천에 접근하여 직접유량계측이 위험하고 정확도 확보가 어려울 경우전자파를 이용하여 비접촉식으로 유량을 계측하는 장비로 홍수기 및 평갈수기에도 하천 유량계측에 활용되기 시작하였다. 전자파표면유속계는 사용법이 간단하고 간접적으로 유속을 측정하기 때문에 기존의 직접측정 방법에 비해 안전한 장점이 있어 현재 국내에서는 홍수기 또는 접근이 어려운 하천의 유속 측정을 위해 사용되고 있다. 국내에서는 1993년 유량측정 장치 개발을 위해 전자파표면유속계(MWSCM; Microwave Water Surface Current Meter)를 개발을 연구를 수행하였고, 최근에는 국내에서 개발된 전자파표면유속계을 활용하여 유량측정을 위해 사용되고 있다. 하지만 국내에서 개발된 전자파표면유속계가 실제 하천에서 유속측정의 정확도에 대한 연구는 부족한 실정이다. 전자파표면유속계는 기기로부터 전자파를 이용해 유속을 측정하기 때문에 수직각과 편각과 같은 각도 변화에 따라 측정정확도가 바뀔 수 있고, 전자파표면유속계 본체에서 발사되는 전자파의 측정영역에 따라 유속측정에 오차가 발생할 수 있다. 본 연구에서는 국내에서 개발 전자파표면유속계의 측정정확도를 분석하기 위해서 실제하천과 유사한 실규모 하천수로에서 수직각과 편각을 변화시키며 측정을 수행하여 수직각과 편각에 변화에 따른 유속측정 정확도를 분석하였다. 그리고 전자파표면유속계의 측정영역의 고려를 통해서 측정영역에 따른 유속측정결과를 분석하였다. 유속측정 결과를 통해서 수직각 15° 이하에서는 유속측정의 오차가 커지게 되는 것으로 나타났고, 편각이 커질수록 유속측정의 결과의 변동계수가 커지는 것으로 나타났다. 그리고 편각에 따른 오차의 영향은 전자파표면유속계의 측정영역에 따라 결과가 달라지는 것으로 나타났다.

Shoulder Arthrokinematics of Collegiate Ice Hockey Athletes Based on the 3D-2D Model Registration Technique

  • Jeong, Hee Seong;Song, Junbom;Lee, Inje;Kim, Doosup;Lee, Sae Yong
    • 한국운동역학회지
    • /
    • 제31권3호
    • /
    • pp.155-161
    • /
    • 2021
  • Objective: There is a lack of studies using the 3D-2D image registration techniques on the mechanism of a shoulder injury for ice hockey players. This study aimed to analyze in vivo 3D glenohumeral joint arthrokinematics in collegiate ice hockey athletes and compare shoulder scaption with or without a hockey stick using the 3D-2D image registration technique. Method: We recruited 12 male elite ice hockey players (age, 19.88 ± 0.65 years). For arthrokinematic analysis of the common shoulder abduction movements of the injury pathogenesis of ice hockey players, participants abducted their dominant arm along the scapular plane and then grabbed a stick using the same motion under C-arm fluoroscopy with 16 frames per second. Computed tomography (CT) scans of the shoulder complex were obtained with a 0.6-mm slice pitch. Data from the humerus translation distances, scapula upward rotation, anterior-posterior tilt, internal to external rotation angles, and scapulohumeral rhythm (SHR) ratio on glenohumeral (GH) joint kinematics were outputted using a MATLAB customized code. Results: The humeral translation in the stick hand compared to the bare hand moved more anterior and more superior until the abduction angle reached 40°. When the GH joint in the stick hand was at the maximal abduction of the scapula, the scapula was externally rotated 2~5° relative to 0°. The SHR ratio relative to the abduction along the scapular plane at 40° indicated a statistically significant difference between the two groups (p < 0.05). Conclusion: With arm loading with the stick, the humeral and scapular kinematics showed a significant correlation in the initial section of the SHR. Although these correlations might be difficult in clinical settings, ice hockey athletes can lead to the movement difference of the scapulohumeral joints with inherent instability.