• Title/Summary/Keyword: Laval Nozzle

Search Result 22, Processing Time 0.035 seconds

Modelling and Analysis of Electrodes Erosion Phenomena of $SF_6$ Arc in a Laval Nozzle

  • Lee, Byeong-Yoon;Liau, Vui Kien;Song, Ki-Dong;Park, Kyong-Yop
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.972-974
    • /
    • 2005
  • The present work deals with the theoretical study of the effects of copper vapours resulting from the erosion of the electrodes on the properties of a SF6 arc in a Laval nozzle. Computations have been done for a DC arc of 1000A with upstream gas pressure of 3.75MPa. The arc plasma is assumed to be in local thermodynamic equilibrium(LTE). The sheath and non-equilibrium region around the electrodes are not considered in this model. However, its effects on the energy flux into the electrodes are estimated from some experimental and theoretical data. The turbulence effects are calculated using the Prandtl mixing length model. A conservation equation for the copper vapour concentration is solved together with the governing equations for mass, momentum and energy of the gas mixture. Comparisons were made between the results with and without electrodes erosion. It has been found that the presence of copper vapours cools down the arc temperature due to the combined effects of increased radiation and increased electrical conductivity. The copper vapour distribution is very sensitive to the turbulent parameter. The erosion of upstream electrode(cathode) has larger effects on the arc compared to the downstream electrode(anode) as the copper vapour eroded from the anode cannot diffuse against the high-speed axial flow.

  • PDF

Aerosol Deposition Nozzle Design for Uniform Flow Rate: Divergence Angle and Nozzle Length

  • Kim, Jae Young;Kim, Young Jin;Jeon, Jeong Eun;Jeon, Jun Woo;Choi, Beom Soo;Choi, Jeong Won;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.2
    • /
    • pp.38-44
    • /
    • 2022
  • Plasma density in semiconductor fabrication equipment becomes higher to achieve the improved the throughput of the process, but the increase of surface corrosion of the ceramic coated chamber wall has been observed by the increased plasma density. Plasma chamber wall coating with aerosol deposition prefer to be firm and uniform to prevent the potential creation of particle inside the chamber from the deformation of the coating materials, and the aerosol discharge nozzle is a good control factor for the deposited coating condition. In this paper, we investigated the design of the nozzle of the aerosol deposition to form a high-quality coating film. Computational fluid dynamics (CFD) study was employed to minimize boundary layer effect and shock wave. The degree of expansion, and design of simulation approach was applied to found out the relationship between the divergence angle and nozzle length as the key parameter for the nozzle design. We found that the trade-off tendency between divergence angle and nozzle length through simulation and quantitative analysis, and present the direction of nozzle design that can improve the uniformity of chamber wall coating.

Design of the Main Nozzle with Different Acceleration Tube and Diameter in an Air-Jet Loom

  • Jeong, Seok-Yoon;Kim, Kyung-Hoon;Choi, Jin-Hwan;Lee, Chan-kyu
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 2005
  • The air-jet loom represents a major step in the development of shutterless weaving due to its ability to weave a wide range of yarns at high speeds. The air-jet weaving involves inserting a pre-measured length of yarn through the wraps, which is shed by means of compressed air. The analysis of air flow characteristic of the main nozzle and acceleration tube is required for improving the loom performance. In this paper, we examined the effects of the main nozzle with different acceleration tubes as well as diameters. Also, we compared the performance of a straight-type tube with a Laval-type tube and the effect of installing a suction hole on the acceleration tube.

Flow Characteristics of the Main Nozzle with different Acceleration Tube and Diameter in an Air-Jet Loom (에어젯트 직기에서 가속관 직경변화에 따른 주노즐의 유동특성)

  • Jeong, S.Y.;Kim, K.H.
    • Journal of ILASS-Korea
    • /
    • v.8 no.2
    • /
    • pp.16-23
    • /
    • 2003
  • The Air-jet loom represents a major step in the development of shutterless weaving due to its ability to weave a wide range of yarns at high speeds. The Air-jet weaving involvers, inserting a pre-measured length of yam through the wrap, is sheds by meads of compressed air. The analysis of air flow characteristic of the main nozzle and acceleration tube is required for the loom performance. h this paper We examined the effect of the main nozzle with different acceleration tubes as well as diameters. And also, we compared the performance of straight type tube with laval type tube and of according to be suction hole on the acceleration tube, respectively.

  • PDF

Study of Internal Flow in the supersonic Nozzle by the Hydraulic Analogy (수력학적 상사를 적용한 초음속 노즐 내부 유동 연구)

  • Lee, Ji-Hyung;Lee, Kyung-Hun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.477-482
    • /
    • 2009
  • Though rocket nozzle flow is very important to the rocket performance, the direct measurement is very difficult because of high temperature and high pressure gas flow. Then the experiment utilizing the hydraulic analogy has been developed for such a problem. Supersonic flows through an axisymmetric De Laval nozzle of solid rocket motor was simulated in a 2-D sluice-type water-table designed and manufactured utilizing hydraulic analogy. Methods to minimize or account for non-analogous effects in the hydraulic system must be reviewed for the quantitative application of the hydraulic analogy. In this application the water table is inclined slightly, so that gravity acceleration has a small component in the direction of motion, thus compensating for the effect of friction. Flow visualization leads to better understanding of the analogous system. Within the experimental errors, it is shown that the hydraulic analogy can be used as an effective tool for the study of two dimensional isentropic flows of gases in many fields.

  • PDF

A Numerical Analysis of Flow Field in the Silt Nozzle During Cold Spray Coating Process (저온분사 코팅공정에서 초음속 슬릿노즐 사용시 유동장 해석)

  • Park, Hye-Young;Park, Jong-In;Jung, Hun-Je;Jang, Kyoung-Soo;Baek, Ui-Hyun;Han, Jeong-Whan;Kim, Hyung-Jun
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.3
    • /
    • pp.221-230
    • /
    • 2011
  • The cold spray process is an emerging technology that utilizes high velocity metallic particles for surface coating. Metallic powder particles are injected into a converging-diverging de Laval nozzle and accelerated to a high velocity by a supersonic gas flow. The cold spray process normally uses a circular nozzle that has a rather narrow spraying range. To overcome this fault, a slit nozzle was considered in this study. The slit nozzle is anticipated to reduce the coating process time because it has a wider coating width than the circular nozzle. However, the slit nozzle can reduce the coating efficiency because it does not allow as much gas and particle velocity as the circular nozzle. To improve the coating efficiency of a slit nozzle, the shape of the slit nozzle was modified. And the results of gas flow and particle behaviour according to the nozzlers shape were compared by the a numerical analysis. As a results, as Expansion Ratio(ER) of 7.5 was found to be the most optimal condition for enhancing the spraying efficiency when the ER was changed by the variation of nozzle neck and exit size.

Nozzle and Gas Jet Flow in Laser Cutting (레이저 절단에서의 노즐 및 가스제트의 영향)

  • 방세윤;한유희
    • Journal of Welding and Joining
    • /
    • v.12 no.2
    • /
    • pp.1-10
    • /
    • 1994
  • 노즐에서 분사되는 제트의 거동에 대해 전반적으로 고찰해보고, 실제 후판의 레이저 절단성 실험 을 통해 노즐의 영향 및 혼합가스의 절단면 질 향상효과 등을 살펴보았다. 간략히 요약하면 다음 과 같다. 아음속제트는 노즐압력을 증가함에 따라 절단압력도 증가하지만 노즐과 재료사이의 거 리를 가능한 작게 유지하여야 하는 제약이 있다. 따라서 사용중에 손상이 가기 쉽다. 이를 해결하 고자 초음속제트의 사용이 연구되고 있지만 shock의 형성으로 인해 노즐압과 절단압은 매우 비선 형적인 관계를 갖는다. 따라서 (i)고압에서도 MSD가 형성되지 않고 주기적인 압력 재상승이 나 타나도록 하거나, (ii)Laval노즐을 이용해 shock구조가 형성되지 않고 큰 절단거리를 얻도록 하는 방법이 제시되고 있다. 초음속노즐의 후판 절단 적용 가능성을 분석해 본 결과 유동 박리 현상으 로 인해 후판보다는 박판의 향상을 위해서는 적절한 조성의 혼합가스를 사용하는 것이 아주 효과 적이었으며, 보조 가수 제트를 채용해 slag제거를 효율적으로 수행 할 수 있음을 확인하였다.

  • PDF

The Unsteady Cavity Flow Oscillation in Supersonic Moisture Air Stream (초음속 습공기 유동에서 비정상 공동유동의 진동)

  • Shin, Choon-Sik;Lee, Jong-Sung;Kim, Heuy-Dong;Setoguchi, Toshiaki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.341-344
    • /
    • 2008
  • Numerical simulations have been carried out for a supersonic two-dimensional flow over open, rectangular cavities (length-to-depth ratios are L/D = 1.0) in order to investigate the effect of non-equilibrium condensation of moist air on supersonic flows around the cavity for the flow Mach number 1.83 at the cavity entrance. In the present computational investigation, a condensing flow was produced by an expansion of moist air in a Laval nozzle. The results obtained showed that in the case with non-equilibrium condensation for L/D = 1.0, amplitudes of oscillation in the cavity became smaller than those without the non-equilibrium condensation. Furthermore, the occurrence of the non-equilibrium condensation reduced the peaks of power spectrum density and the frequency of the flow field oscillation increased in comparison with the case of $S_0$ = 0.

  • PDF

Numerical Study of SF6 arc with Copper Contamination

  • Liau Vui-Kien;Lee Byeong-Yoon;Song Ki-Dong;Park Kyong-Yop
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.6
    • /
    • pp.233-241
    • /
    • 2005
  • The present model of a SF6 arc accounts for the copper vapour contamination from the electrodes inside a Laval nozzle of a circuit breaker. Steady state simulations have been done for the arc with electrode gap of 60mm and DC electric current of 500A, 1000A and 1500A for both cases with and without copper contamination. The effects of electrode polarity are considered for the arc current of 1000A. It was found out that evaporation of copper from the anode results in a cooling of the arc in a region close to the electrodes. The electrical potential across the electrodes is not sensitive to the presence of copper vapour, typically less than $4\%$ difference. Transient analysis has been done in order to obtain the arc properties at current zero. The arc current is increased linearly from -1000 to 0A when the upstream electrode is cathode with constant dI/dt of $27.0A/{\mu}s$ (or decreased linearly from 1000 to 0A when upstream electrode is anode). It has been predicted that the presence of copper vapour reduces the interruption capability of the breaker.