• 제목/요약/키워드: Lateral-superior

검색결과 357건 처리시간 0.027초

Seismic response estimation of steel buildings with deep columns and PMRF

  • Reyes-Salazar, Alfredo;Soto-Lopez, Manuel E.;Gaxiola-Camacho, Jose R.;Bojorquez, Eden;Lopez-Barraza, Arturo
    • Steel and Composite Structures
    • /
    • 제17권4호
    • /
    • pp.471-495
    • /
    • 2014
  • The responses of steel buildings with perimeter moment resisting frames (PMRF) with medium size columns (W14) are estimated and compared with those of buildings with deep columns (W27), which are selected according to two criteria: equivalent resistance and equivalent weight. It is shown that buildings with W27 columns have no problems of lateral torsional, local or shear buckling in panel zone. Whether the response is larger for W14 or W27 columns, depends on the level of deformation, the response parameter and the structural modeling under consideration. Modeling buildings as two-dimensional structures result in an overestimation of the response. For multiple response parameters, the W14 columns produce larger responses for elastic behavior. The axial load on columns may be significantly larger for the buildings with W14 columns. The interstory displacements are always larger for W14 columns, particularly for equivalent weight and plane models, implying that using deep columns helps to reduce interstory displacements. This is particularly important for tall buildings where the design is usually controlled by the drift limit state. The interstory shears in interior gravity frames (GF) are significantly reduced when deep columns are used. This helps to counteract the no conservative effect that results in design practice, when lateral seismic loads are not considered in GF of steel buildings with PMRF. Thus, the behavior of steel buildings with deep columns, in general, may be superior to that of buildings with medium columns, using less weight and representing, therefore, a lower cost.

중하부 경추손상에서 후방 경추 내고정술 및 골유합술의 분석결과 (Analysis of Posterior Cervical Fixation and Fusion in Subaxial Cervical Spine Injury)

  • 이동훈;송근성
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권12호
    • /
    • pp.1388-1393
    • /
    • 2001
  • Objective : In the retrospective analyzing 19 consecutive patients with subaxial cervical spine(C3~T1) injury treated by posterior cervical fixation and fusion, clinical manifestation, radiologic finding, operative technique, and postoperative results following 6 months were analyzed. Materials and Methods : Most common fracture level was C4-5, mean age 41, and male to female ratio 13 : 6. The most common cause of injury was motor vehicle accident(17 cases). In 19 cervical procedures, interspinous triple wiring was done in 14 cases, lateral mass plating in 5 cases, and additional anterior fusion in 2 cases. Results : Twelve weeks after operation, all cases were reviewed by plain cervical radiogram. In 17 cases that treated by posterior fusion only, 14 cases(81%) had kyphotic angle change less than $5^{\circ}$, 2 cases(12%) $5-20^{\circ}$, and 1 case(6%) more than $20^{\circ}$. Overall fusion rate was 88%, and there was no significant difference of bone fusion rate between autogenous bone graft and allogenous bone graft. Conclusion : In the case of severe posterior column injury or displacement, posterior approach seems superior to anterior approach, but in the case of combined anterior column injury, anterior approach is considered necessary. In this study, posterior fixation and fusion might be acceptable procedure for subaxial cervical fracture and dislocation, owing to its high fusion rate, low kyphotic angulation and low operation related complication rate.

  • PDF

Clinical Comparison of Posterolateral Fusion with Posterior Lumbar Interbody Fusion

  • Kim, Chang-Hyun;Gill, Seung-Bae;Jung, Myeng-Hun;Jang, Yeun-Kyu;Kim, Seong-Su
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권2호
    • /
    • pp.84-89
    • /
    • 2006
  • Objective : The purpose of this study is to compare the outcomes of two methods for stabilization and fusion : Postero-Lateral Fusion [PLF, pedicle screw fixation with bone graft] and Posterior Lumbar Interbody Fusion [PLIF, cage insertion] for spinal stenosis and recurred disc herniation except degenerative spondylolisthesis. Methods : Seventy one patients who underwent PLF [n=36] or PLIF [n=35] between 1997 and 2001 were evaluated prospectively. These two groups were compared for the change of interbody space, the range of segmental angle, the angle of lumbar motion, and clinical outcomes by Prolo scale. Results : The mean follow-up period was 32.6 months. The PLIF group showed statistically significant increase of the interbody space after surgery. However, the difference in the change of interbody space between two groups was insignificant [P value=0.05]. The range of segmental angle was better in the PLIF group, but the difference in the change of segmental angle was not statistically significant [P value=0.0l7]. Angle of lumbar motion was similar in the two groups. Changes of Prolo economic scale were not statistically significant [P value=0.193]. The PLIF group showed statistically significant improvement in Prolo functional scale [P value=0.003]. In Prolo economic and functional scale, there were statistically significant relationships between follow-up duration [P value<0.001]. change of interbody space [P value<0.001], and range of segmental angle [P value<0.001]. Conclusion : Results of this study indicate that PLIF is superior to PLF in interbody space augmentation and clinical outcomes by Prolo functional scale. Analysis of clinical outcomes showed significant relationships among various factors [fusion type, follow-up duration, change of interbody space, and range of segmental angle]. Therefore, the authors recommend instrumented PLIF to offer better clinical outcomes in patients who needed instrumented lumbar fusion for spinal stenosis and recurred disc herniation.

Biomechanical Study of Lumbar Spinal Arthroplasty with a Semi-Constrained Artificial Disc (Activ L) in the Human Cadaveric Spine

  • Ha, Sung-Kon;Kim, Se-Hoon;Kim, Daniel H.;Park, Jung-Yul;Lim, Dong-Jun;Lee, Sang-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권3호
    • /
    • pp.169-175
    • /
    • 2009
  • Objective : The goal of this study was to evaluate the biomechanical features of human cadaveric spines implanted with the Activ L prosthesis. Methods : Five cadaveric human lumbosacral spines (L2-S2) were tested for different motion modes, i.e. extension and flexion, right and left lateral bending and rotation. Baseline measurements of the range of motion (ROM), disc pressure (DP), and facet strain (FS) were performed in six modes of motion by applying loads up to 8 Nm, with a loading rate of 0.3 Nm/second. A constant 400 N axial follower preload was applied throughout the loading. After the Activ L was implanted at the L4-L5 disc space, measurements were repeated in the same manner. Results : The Activ L arthroplasty showed statistically significant decrease of ROM during rotation, increase of ROM during flexion and lateral bending at the operative segment and increase of ROM at the inferior segment during flexion. The DP of the superior disc of the operative site was comparable to those of intact spine and the DP of the inferior disc decreased in all motion modes, but these were not statistically significant. For FS, statistically significant decrease was detected at the operative facet during flexion and at the inferior facet during rotation. Conclusion : In vitro physiologic preload setting, the Activ L arthroplasty showed less restoration of ROM at the operative and adjacent levels as compared with intact spine. However, results of this study revealed that there are several possible theoretical useful results to reduce the incidence of adjacent segment disease.

전측두엽 절제술시 해마체 절제 범위와 경련 예후 (The Seizure Outcome and Extent of Hippocampal Resection in Anterior Temporal Lobectomy)

  • 이완수;이정교;이상암;강중구;고태성
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권12호
    • /
    • pp.1650-1656
    • /
    • 2000
  • Objective : Little consensus exists concerning which temporal lobe structures need to be resected or how much resection should be done during hippocampal resection. The purpose of this study is to identify whether the extent of hippocampal resection influences seizure after anterior temporal lobectomy. Materials and Methods : The extent of hippocampal resection was assessed in 96 patients who underwent temporal lobectomy for medically intractable complex partial seizures originating from a unilateral seizure focus in the anteromesial temporal lobe. Patients who had structural lesion were excluded from the study. Postoperative magnetic resonance imaging in the coronal and saggital planes were used to quantify the extent of the hippocampal and lateral cortical resection. The patients were divided into two groups. Patients who underwent hippocampal resection to the level of the cerebral peduncle were included in the partial resection group, and those who had resection to the level of the colliculus were assigned to total resection group. Seizure outcomes were defined according to the Engel classification and compared between the two groups. Neuropsychologic outcomes in the selected cases were reviewed. Results : The over-all seizure-free outcome(Engel classification 1) was accomplished in 75%(72/96) of the patients (mean duration of follow-up, 36.8 months). The total hippocampectomy group had a statistically superior seizure outcome than the partial hippocampectomy group(87.3% versus 58.5% seizure-free, p-value=0.001). Also, younger patients had a more favorable outcome. Other variables such as laterality, the extent of lateral cortical resection, age at onset and gender were not significant. The pre- and postoperative memory functions were evaluated in 24 patients. A worse postoperative memory outcome was associated with partial hippocampectomy. However this was not acceptable due to a former bias. Conclusion : The result of this study conforms that aggressive hippocampectomy resulted in a better seizure outcome.

  • PDF

측두하악관절증에서 자기공명영상을 이용한 측두하악관절의 관절강 평가 (Magnetic resonance imaging-based temporomandibular joint space evaluation in tempormandibular disorders)

  • 나경수
    • Imaging Science in Dentistry
    • /
    • 제37권1호
    • /
    • pp.15-18
    • /
    • 2007
  • Purpose : Disc and condylar position were observed on MRIs of temporomandibular joint disorder patients and condylar position agreement between MRI and tranascranal radiography was evaluated. Materials and Methods MRI and transcranial radiographs of both TM joints from 67 patients with temporemandibular disorder were used. On MRI, the position and shape of disc and condylar position as anterior, middle, posterior was evaluated at medial, center, and lateral views. On transcranial radiographs, condylar position was evaluated using the shortest distance from condyle to fossa in anterior, superior, and posterior directions. Results. 1. On MRI, 96 joints (71.6%) of 134 had anterior disc dispalcement with reduction and 38 joints (28.4%) without reduction. 2. Fourteen (14.6%) of 96 reducible joints showed anterior condylar position, 19 (19.8%) showed central position, 63 joints (65.6%) showed posterior position. Two joints (5.3%) of 38 non-reducible joints showed anterior condylar position, while 9 (23.7%) showed central position, and 27 (71.1%)-posterior position. 3. In 85 joints (63.4%) of 134, the transcranial condylar position agreed with that of the central MRI view, 10 joints (7.5%) with that of medial, 16 joints (11.9%) with that of lateral, and 23 joints (17.2%) disagreed with that of MRI. Conclusion : On MRT, most oi the reducible and non-reducible joints showed posterior condylar position. Transcranial radiographs taken with machine designed for TMJ had better agreement of condylar position with that of MRI. Extremely narrow joint spaces or very posterior condylar positions observed on transcranial radiographs had a little more than fifty percent agreement with those of MRIs.

  • PDF

Effects of bracket slot size during en-masse retraction of the six maxillary anterior teeth using an induction-heating typodont simulation system

  • Kim, Ji-Yong;Yu, Won-Jae;Koteswaracc, Prasad N.K.;Kyung, Hee-Moon
    • 대한치과교정학회지
    • /
    • 제47권3호
    • /
    • pp.158-166
    • /
    • 2017
  • Objective: To investigate how bracket slot size affects the direction of maxillary anterior tooth movement when en-masse retraction is performed in sliding mechanics using an induction-heating typodont simulation system. Methods: An induction-heating typodont simulation system was designed based on the Calorific Machine system. The typodont included metal anterior and resin posterior teeth embedded in a sticky wax arch. Three bracket slot groups (0.018, 0.020, and 0.022 inch [in]) were tested. A retraction force of 250 g was applied in the posterior-superior direction. Results: In the anteroposterior direction, the cusp tip of the canine in the 0.020-in slot group moved more distally than in the 0.018-in slot group. In the vertical direction, all six anterior teeth were intruded in the 0.018-in slot group and extruded in the 0.020- and 0.022-in slot groups. The lateral incisor was significantly extruded in the 0.020- and 0.022-in slot groups. Significant differences in the crown linguoversion were found between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the central incisor and between the 0.018- and 0.022-in slot groups and 0.020- and 0.022-in slot groups for the canine. In the 0.018-in slot group, all anterior teeth showed crown mesial angulation. Significant differences were found between the 0.018- and 0.022-in slot groups for the lateral incisor and between the 0.018- and 0.020-in slot groups and 0.018- and 0.022-in slot groups for the canine. Conclusions: Use of 0.018-in slot brackets was effective for preventing extrusion and crown linguoversion of anterior teeth in sliding mechanics.

연장된 속눈썹 밑 절개선을 이용한 협부당김술을 통한 노화된 가운데얼굴의 개선 (Superficial Subciliary Cheek Lift for Rejuvenating Infraorbital Region and Orbitomalar Groove)

  • 유영천;임대원;박준;양원용
    • Archives of Plastic Surgery
    • /
    • 제34권2호
    • /
    • pp.250-257
    • /
    • 2007
  • Purpose: Aging changes of midface include drooping of lower lid, wrinkles of malar area, orbitomalar groove and deepening of nasolabial fold from drooping of malar fat pad. Improvement of lower lid can be achieved through lower blepharoplasty, but improvement of cheek can not be gained. Superficial subciliary cheek lift(by Moelleken, 1996) is a method that lifts malar fat pad through extended subciliary incision. We obtained simultaneous improvement of lower lid, malar wrinkles and orbitomalar groove with modification of this technique. Methods: From December 2003 to January 2006, we performed this method on 21 patients among volunteers for lower blepharoplasty who wanted to correct orbitomalar groove and malar wrinkles. Under local anesthesia, lateral extension of subciliary incision is done 1cm from the lateral orbital rim. Skin-muscle flap is elevated, and dealing of orbital fat and septum is the same as with ordinary lower blepharoplasty. After downward subcutaneous dissection through extended incision, exposing the upper 1/3 level of malar fat pad, superolateral fixation is done to superior deep temporal fascia. Excision of the upper part of fat pad is performed, if needed. After excision of overlapped skin-muscle flap, skin closure is done. Results: We obtained satisfactory results with this simple method for improvement of orbitomalar groove and malar wrinkles among patients for lower blepharoplasty. During a follow-up period of 5 months on the average, no revision was performed. Conclusion: Under local anesthesia, lower blepharoplasty and improvement of orbitomalar groove and malar wrinkles can be achieved at the same time. It is good for patients who do not want conventional midface-lifting. But surgeons should select patients and perform cautiously for it may leave a scar of the extended incision that require over 2 months for maturation and it is insufficient for improvement of nasolabial fold compared to conventional mid face-lifts.

투석하지 않는 만성신질환 환자에서 cilostazol 투여 중에 발생한 복벽의 자발성 근육내 혈종 (Spontaneous abdominal intramuscular hematoma in a non-dialysis chronic kidney disease patient under cilostazol therapy)

  • 강성희;유형민;나하영;고영경;권세웅;임채호;김선웅;조영일
    • Journal of Yeungnam Medical Science
    • /
    • 제31권2호
    • /
    • pp.139-143
    • /
    • 2014
  • Spontaneous intramuscular hematoma of the abdominal wall is a rare condition characterized by acute abdominal pain. It is often misdiagnosed as a surgical condition. It used to be associated with risk factors such as coughing, pregnancy, and anticoagulant therapy. Most cases of abdominal wall hematomas were rectus sheath hematomas caused by the rupture of either the superior or inferior epigastric artery, but spontaneous internal oblique hematoma was extremely rare. In this report, we present a case of spontaneous internal oblique hematoma in a 69-year-old man with non-dialysis chronic kidney disease who was taking cilostazol. The patient complained of abrupt abdominal pain with a painful palpable lateral abdominal mass while sleeping. The abdominal computed tomography showed an 8 cm-sized mass in the patient's left internal oblique muscle. The administration of cilostazol was immediately stopped, and the intramuscular hematoma of the lateral oblique muscle disappeared with conservative management.

Hysteretic performance of SPSWs with trapezoidally horizontal corrugated web-plates

  • Kalali, Hamed;Hajsadeghi, Mohammad;Zirakian, Tadeh;Alaee, Farshid J.
    • Steel and Composite Structures
    • /
    • 제19권2호
    • /
    • pp.277-292
    • /
    • 2015
  • Previous research has shown that steel plate shear walls (SPSWs) are efficient lateral force-resisting systems against both wind and seismic loads. A properly designed SPSW can have high initial stiffness, strength, and energy absorption capacity as well as superior ductility. SPSWs have been commonly designed with unstiffened and stiffened infill plates based on economical and performance considerations. Recent introduction and application of corrugated plates with advantageous structural features has motivated the researchers to consider the employment of such elements in stiffened SPSWs with the aim of lowering the high construction cost of such high-performing systems. On this basis, this paper presents results from a numerical investigation of the hysteretic performance of SPSWs with trapezoidally corrugated infill plates. Finite element cyclic analyses are conducted on a series of flat- and corrugated-web SPSWs to examine the effects of web-plate thickness, corrugation angle, and number of corrugation half-waves on the hysteretic performance of such structural systems. Results of the parametric studies are indicative of effectiveness of increasing of the three aforementioned web-plate geometrical and corrugation parameters in improving the cyclic response and energy absorption capacity of SPSWs with trapezoidally corrugated infill plates. Increasing of the web-plate thickness and number of corrugation half-waves are found to be the most and the least effective in adjusting the hysteretic performance of such promising lateral force-resisting systems, respectively. Findings of this study also show that optimal selection of the web-plate thickness, corrugation angle, and number of corrugation half-waves along with proper design of the boundary frame members can result in high stiffness, strength, and cyclic performances of such corrugated-web SPSWs.