• Title/Summary/Keyword: Lateral-superior

Search Result 357, Processing Time 0.028 seconds

Selection of New Variety of Rubus coreanus Miq., "Doo-Ryun", with Large Fruit and High Yield (대립 다수성 복분자딸기 "두륜")

  • Kim, Sea-Hyun;Han, Jingyu
    • Korean Journal of Breeding Science
    • /
    • v.41 no.2
    • /
    • pp.126-129
    • /
    • 2009
  • The new Rubus coreanus Miq. variety, 'Doo-Ryun', was selected from 227 clones of the clone bank. This breeding was progressed to select the superior variety for high productivity from 1998 to 2005. To evaluate the clones, characteristics of a fruiting lateral and a ripe fruit were investigated. 'Doo-Ryun' was finally selected through selection of three times and stable trial at four different regions. 'Doo-Ryun' has specific morphological characteristics that are fewer thorn in lateral and strong glossiness of leaf upper side than contrast clone. The flowing and fruiting characteristics of 'Doo-Ryun' shown that the number of flower per fruitng lateral, the number of fruit per fruiting lateral, fruit weight and yield per individual were 17.2, 16.9, 1.73g and 4.50kg, respectively. Also, their selection effects were evaluated as 103.6%, 107.6%, 140.6% and 155.7% compared to the mean of whole clones in the clone bank, respectively.

Effect of cohesion of infill materials on the performance of geocell-reinforced cohesive soil subgrade

  • Yang Zhao;Zheng Lu;Jie Liu;Lei Ye;Weizhang Xu;Hailin Yao
    • Geomechanics and Engineering
    • /
    • v.33 no.3
    • /
    • pp.301-315
    • /
    • 2023
  • Adopting cohesive soil as geocell-pocket infill materials is not fully accepted by researchers in the field of road engineering. The cohesion that may inhibit the lateral limitation of geocells is a common vital idea that exists within every researcher. However, the influence of infill materials' cohesion on geocell-reinforced performance is still not thoroughly determined. The mechanism behind this still needs to be studied in depth. This study initially discussed the relationship between subgrade bearing capacity, geocells' contribution to reinforced performance, and infill materials' cohesion (IMC). A law was proposed that adopting the soil with high cohesion as infill materials benefited the subgrade bearing capacity, but this was attributed to the superior mechanical properties of infill materials rather than geocells' contribution. Moreover, the vertical and lateral deformation of subgrade, coupling shear stress and confining stress of geocells, and deformation of geocells were deeply studied to analyze the mechanism that high cohesion can inhibit the geocells' contribution. The results indicate that the infill materials with high cohesion result in the total displacement of the subgrade toward to deeper depth, not the lateral direction. These responses decrease the vertical coupling shear stress, confining stress, and normal displacement of geocell walls, which weaken the lateral limitation of geocells.

Postoperative Clinical Outcome and Risk Factors for Poor Outcome of Foraminal and Extraforaminal Lumbar Disc Herniation

  • Bae, Jung Sik;Kang, Kyung Hee;Park, Jeong Hyun;Lim, Jae Hyeon;Jang, Il Tae
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.2
    • /
    • pp.143-148
    • /
    • 2016
  • Objective : We evaluated postoperative outcomes in patients who have lumbar foraminal or extraforaminal disc herniation (FELDH) and suggested the risk factors for poor outcomes. Methods : A total of 234 patients were selected for this study. Pre- and post-operative Visual Analogue Scale (VAS) and Korean version Oswestry Disability Index (KODI) were evaluated and the changes of both score were calculated. Outcome was defined as excellent, good, fair, and poor based on Mcnab classification. The percentage of superior facetectomy was calculated by using the Maro-view 5.4 Picture Archiving Communication System (PACS). Results : Paramedian lumbar discectomy was performed in 180 patients and combined lumbar discectomy was performed in 54 patients. Paramedian lumbar discectomy group showed better outcome compared with combined discectomy group. p value of VAS change was 0.009 and KODI was 0.013. The average percentage of superior facetectomy was 33% (range, 0-79%) and it showed negative correlation with VAS and KODI changes (Pearson coefficient : -0.446 and -0.498, respectively). Excellent or good outcome cases (Group I) were 136 (58.1%) and fair or poor outcome cases (Group II) were 98 (41.9%). The percentage of superior facetectomy was 26.5% at Group I and 42.5% at Group II. There was significant difference in superior facetectomy percentage between Group I and II (p=0.000). Conclusion : This study demonstrated that paramedian lumbar discectomy with preservation of facet joints is an effective and good procedure for FELDH. At least 60% of facet should be preserved for excellent or good outcomes.

New insight into the vasto-adductor membrane for safer adductor canal blockade

  • Yanguk Heo;Miyoung Yang;Sung Min Nam;Hyun Seung Lee;Yeon-Dong Kim;Hyung-Sun Won
    • The Korean Journal of Pain
    • /
    • v.37 no.2
    • /
    • pp.132-140
    • /
    • 2024
  • Background: This study aimed to identify exact anatomical landmarks and ideal injection volumes for safe adductor canal blocks (ACB). Methods: Fifty thighs from 25 embalmed adult Korean cadavers were used. The measurement baseline was the line connecting the anterior superior iliac spine (ASIS) to the midpoint of the patellar base. All target points were measured perpendicular to the baseline. The relevant cadaveric structures were observed using ultrasound (US) and confirmed in living individuals. US-guided dye injection was performed to determine the ideal volume. Results: The apex of the femoral triangle was 25.3 ± 2.2 cm distal to the ASIS on the baseline and 5.3 ± 1.0 cm perpendicular to that point. The midpoint of the superior border of the vasto-adductor membrane (VAM) was 27.4 ± 2.0 cm distal to the ASIS on the baseline and 5.0 ± 1.1 cm perpendicular to that point. The VAM had a trapezoidal shape and was connected as an aponeurosis between the medial edge of the vastus medialis muscle and lateral edge of the adductor magnus muscle. The nerve to the vastus medialis penetrated the muscle proximal to the superior border of the VAM in 70% of specimens. The VAM appeared on US as a hyperechoic area connecting the vastus medialis and adductor magnus muscles between the sartorius muscle and femoral artery. Conclusions: Confirming the crucial landmark, the VAM, is beneficial when performing ACB. It is advisable to insert the needle obliquely below the superior VAM border, and a 5 mL injection is considered sufficient.

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

A voxel based morphometry study in Alzheimer's disease

  • Rahyeong Juh;Taesuk Suh;Boyoung Choe;Lee, Changuk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.46-46
    • /
    • 2003
  • Several MRI studies have reported reductions in temporal lobe volumes in Alzheimer´s disease (AD). Measures have been usually obtained with regions of interest (ROI) drawn manually on selected medial and lateral portions of the temporal lobes, with variable choices of anatomical borders across different studies. We used the automated voxel based morphometry (VBM) approach to investigate gray matter abnormalities over the entire extension of the temporal lobe in 11 AD patients (MMSE 14 - 25) and 11 healthy controls. Foci of significantly reduced gray matter volume in AD patients were detected in both medial and lateral temporal regions, most significantly in the right and left posterior parahippocampal gyri. At a more flexible statistical threshold (P<0.001, uncorrected for multiple comparisons), circumscribed foci of significant gray matter reduction were also detected in the right amygdala/enthorinal cortex, the anterior and posterior borders of the superior temporal gyrus bilaterally, and the anterior portion of the left middle temporal gyrus. These VBM results confirm previous findings of temporal lobe atrophic changes in AD, and suggest that these abnormalities may be confined to specific sites within that lobe, rather than showing a widespread distribution.

  • PDF

Seismic Performance of a Hollow Composite Column (강합성 중공 기둥의 내진 성능)

  • Han, Taek Hee;Kim, Jung Hun;Lim, Nam Hyoung;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.2
    • /
    • pp.215-226
    • /
    • 2008
  • A column test was performed for a hollow composite column to evaluate its seismic performance. The seismic performances of a hollow composite column and a reinforced concrete (RC) column were evaluated and compared by quasi-static tests. Lateral displacements and lateral loads of the column specimens were measured during tests. Ductilities, absorbed energy, equivalent damping ratios, and damage indices were calculated from the recorded data. From the test results, the hollow composite column showed a seismic performance superior to the column in terms of double moment capacity, ultimate energy, and energy absorption.

Seismic behaviour of concrete columns with high-strength stirrups

  • Wang, Peng;Shi, Qingxuan;Wang, Feng;Wang, Qiuwei
    • Earthquakes and Structures
    • /
    • v.18 no.1
    • /
    • pp.15-25
    • /
    • 2020
  • The seismic behaviour of reinforced concrete (RC) columns made from high-strength materials was investigated experimentally. Six high-strength concrete specimen columns (1:4 scale), which included three with high-strength stirrups (HSSs) and three with normal-strength stirrups (NSSs), were tested under a combination of high axial and reversed cyclic loads. The effects of stirrup strength and the ratio of transverse reinforcement on the cracking patterns, hysteretic response, strength, stiffness, ductility, energy dissipation and strain of transverse reinforcement were studied. The results indicate that good seismic behaviour of an RC column subjected to high axial compression can be obtained by using a well-shaped stirrup. Stirrup strength had little effect on the lateral bearing capacity. However, the ductility was significantly modified by improving the stirrup strength. When loaded with a large lateral displacement, the strength reduction of NSS specimens was more severe than that of those with HSSs, and increasing the stirrup strength had little effect on the stiffness reduction. The ductility and energy dissipation of specimens with HSSs were superior to those with NSSs. When the ultimate displacement was reached, the core concrete could be effectively restrained by HSSs.

Roll-Pitch-Yaw Integrated H Controller Synthesis for High Angle-of-Attack Missiles

  • Choi, Byung-Hun;Kang, Seon-Hyeok;Kim, H. Jin;Won, Dae-Yeon;Kim, Youn-Hwan;Jun, Byung-Eul;Lee, Jin-Ik
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.9 no.1
    • /
    • pp.66-75
    • /
    • 2008
  • In this work, we explore the feasibility of roll-pitch-yaw integrated autopilots for high angle-of-attack missiles. An investigation of the aerodynamic characteristics of a surface-to-air missile is presented, which reveals the strong effects of cross coupling between the longitudinal and lateral dynamics. Robust control techniques based on $H_{\infty}$ synthesis are employed to design roll-pitch-yaw integrated autopilots. The performance of the proposed roll-pitch-yaw integrated controller is tested in high-fidelity nonlinear five-degree-of-freedom simulations accounting for kinematic cross-coupling effects between the lateral and longitudinal channels. Against nonlinearity and cross-coupling effects of the missile dynamics, the integrated controller demonstrates superior performance when compared with the controller designed in a decoupled manner.

Relation of the measuring values in cephalometric radiographs and TMJ tomographs (두부규격방사선사진과 측두하악관절 단층방사선사진 계측치간의 상관관계)

  • Han, Jin-Woo
    • Imaging Science in Dentistry
    • /
    • v.37 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • Purpose : To examine whether the maxillofacial skeletal morphology correlates with the condylar position and the anatomic characteristics of articular eminence using measurements of lateral cephalometric radiographs and individualized sagittal temporomandibular joint (TMJ) tomographs. Materials and Methods : I compared measurements of 202 TMJs of 101 orthodontic patients of Kangnung National University Dental Hospital. 1 used Pearson's correlation for comparison of the measuring values in lateral cephalometric radiographs and individualized sagittal TMJ tomographs. Results : Large occlusal plane angle tendency showed decreased width of posterior eminence slope, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large mandibular plane angle tendency showed decreased superior joint space, decreased depth of articular fossa and decreased posterior slope angle of eminence. Large genial angle tendency showed decreased depth of articular fossa, decreased posterior slope angle of eminence and anterior position of condylar head. Large anterior facial height and large posterior facial height tendency showed increased width of posterior slope of eminence, increased depth of articular fossa, increased posterior slope angle of eminence and posterior position of condylar head. Conclusion : Maxillofacial skeletal morphology has correlation with the anatomic characteristics of TMJ. Individualized sagittal TMJ tomographs can provide useful information for anatomical analysis of TMJ.

  • PDF