• 제목/요약/키워드: Lateral load and shaking table test

검색결과 14건 처리시간 0.03초

가압고정 기계적이음을 활용한 프리캐스트 콘크리트 구조물의 준정적 및 진동대 실험 (Quasi-Static and Shaking Table Tests of Precast Concrete Structures Utilizing Clamped Mechanical Splice)

  • 성한석;안성룡;박시영;강현구
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.37-47
    • /
    • 2023
  • A new clamped mechanical splice system was proposed to develop structural performance and constructability for precast concrete connections. The proposed mechanical splice resists external loading immediately after the engagement. The mechanical splices applicable for both large-scale rebars for plants and small-scale rebars for buildings were developed with the same design concept. Quasi-static lateral cyclic loading tests were conducted with reinforced and precast concrete members to verify the seismic performance. Also, shaking table tests with three types of seismic wave excitation, 1) random wave with white noise, 2) the 2016 Gyeongju earthquake, and 3) the 1999 Chi-Chi earthquake, were conducted to confirm the dynamic performance. All tests were performed with real-scale concrete specimens. Sensors measured the lateral load, acceleration, displacement, crack pattern, and secant system stiffness, and energy dissipation was determined by lateral load-displacement relation. As a result, the precast specimen provided the emulative performance with RC. In the shaking table tests, PC frames' maximum acceleration and displacement response were amplified 1.57 - 2.85 and 2.20 - 2.92 times compared to the ground motions. The precast specimens utilizing clamped mechanical splice showed ductile behavior with energy dissipation capacity against strong motion earthquakes.

지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험 (Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building)

  • 김진구;송영훈;권형오;허영
    • 소음진동
    • /
    • 제7권5호
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF

비내진 상세를 가진 3층 철근콘크리트 골조의 비탄성 거동 (Inelatic Behaviors of A 3-Story Reinforced Concrete Frame with Nonseismic Details)

  • 이한선;우성우;허윤섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회논문집(II)
    • /
    • pp.427-432
    • /
    • 1998
  • The objective of this research is to observe the actual response of low-rise nonseismic moment-resisting reinforced frame subjected to varied levels of earthquake ground motions. First of all, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelerations(PGA's) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The global behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of structure were measured. The base shear was measured by using specially made load cells. Before and after each earthquake simulation test, free vibration tests were performed to find the changes in the natural period and damping ratio of the model.

  • PDF

형상비 3.5 RC교각의 실험 방법에 의한 내진성능 분석 (Seismic Performance Analysis of RC Bridge Piers with 3.5 Aspect Ratio depending on Testing Methods)

  • 홍현기;박창영;정영수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.93-96
    • /
    • 2008
  • 이 논문은 근단층지반운동(NFGM)하에서 내진성능을 평가하기 위한 RC교각의 진동대, 준정적, 유사동적 실험을 다룬다. 5개의 실험체가 수행되었다. 축소 모형을 제작하고 상부구조물의 중량 에 의한 축력의 효과는 프리스트레스에 의해 구현하였다. 지진이 발생할 때 상부 구조물의 횡방향 관성력은 진동대의 제한된 용량 때문에 교각 실험체에 연결한 질량 프레임으로 모사하였다. 특히, 진동대 실험에서 질량 모사 프레임이 교각 모델과 같은 변위로 움직이면서 마찰 효과를 최소화할 수 있도록 고려하였고 이에 대한 검증을 실시하였다. RC교각의 축소 계수를 4.25로 설정 하였다.

  • PDF

진동대실험을 사용한 비보강 및 ECC 자켓 보강 조적담장의 내진성능평가 (Seismic Performance Evaluation of Unreinforced and ECC-jacketed Masonry Fences using Shaking Table Test)

  • 이용훈;김진우;김재환;엄태성;이상현
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제27권6호
    • /
    • pp.182-192
    • /
    • 2023
  • 본 연구에서는 동적 횡하중을 받는 조적 담장의 내진성능 향상을 위한 ECC(Engineered Cementitious Composite) 자켓의 효과를 실험적으로 검증하였다. 첫째로, 임팩트 해머 시험을 통해 비보강과 ECC로 보강된 조적 담장의 고유진동수와 모드 감쇠비, 변형 형상을 식별하여, 940mm의 비보강 조적담장과 970mm의 ECC 보강 담장이 각각 6.4, 35.3Hz의 고유진동수와 7.0, 5.3%의 감쇠비를 가지는 것을 확인하였다. 둘째로, 진동대를 사용하여 면외방향에 대한 지진파 실험을 수행하였고, El Centro(1940) 지진파를 25%부터 300%까지 스케일링하여 적용하였다. 비보강 조적담장의 경우, 50% 지진하중에서 벽돌과 줄눈 경계에 휨균열이 발생하였고, 다시 30%로 스케일링된 지반운동에서 면외방향으로 전도파괴되었다. 반면에 ECC로 보강된 조적담장은 300%의 지진하중에서도 균열이나 손상 없이 강건한 성능을 유지하였다. 마지막으로, 25~300%의 지반운동에 의한 비보강과 ECC 보강 조적담장의 밑면전단력과 설계기준에 따른 밑면전단력을 비교 및 평가하였다. 그 결과, 재현주기 1,000년의 지진에 대해 비보강 조적담장이 붕괴될 위험이 있는 데 반해, ECC 보강 담장은 4,800년 주기의 지진에도 안전한 것으로 추정되었다.

Seismic Response Analysis of Reinforced Concrete Wall Structure Using Macro Model

  • Kim, Dong-Kwan
    • International Journal of Concrete Structures and Materials
    • /
    • 제10권1호
    • /
    • pp.99-112
    • /
    • 2016
  • During earthquake, reinforced concrete walls show complicated post-yield behavior varying with shear span-to-depth ratio, re-bar detail, and loading condition. In the present study, a macro-model for the nonlinear analysis of multi-story wall structures was developed. To conveniently describe the coupled flexure-compression and shear responses, a reinforced concrete wall was idealized with longitudinal and diagonal uniaxial elements. Simplified cyclic material models were used to describe the cyclic behavior of concrete and re-bars. For verification, the proposed method was applied to various existing test specimens of isolated and coupled walls. The results showed that the predictions agreed well with the test results including the load-carrying capacity, deformation capacity, and failure mode. Further the proposed model was applied to an existing wall structure tested on a shaking table. Three-dimensional nonlinear time history analyses using the proposed model were performed for the test specimen. The time history responses of the proposed method agreed with the test results including the lateral displacements and base shear.

좌굴을 고려한 액상화 지반에 근입된 말뚝의 파괴거동 분석 (Analysis of Failure Behavior of Pile Embedded in Liquefiable Soil Deposits considering Buckling Instability)

  • 한진태;조종석;황재익;김명모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.105-112
    • /
    • 2006
  • Liquefaction-induced lateral spreading has been the most extensive damage to pile foundations during earthquakes. However, a case of pile failure was reported despite the fact that a large margin of safety factor was employed in their design. This means that the current seismic design method of pile is not agreeable with the actual failure mechanism of pile. Newly proposed failure mechanism of pile is a pile failure based on buckling instability. In this study, failure behavior of pile embedded in liquefied soil deposits was analyzed considering lateral spreading and buckling instability performing 1g shaking table test. As a result, it can be concluded that the pile subjected to excessive axial loads ($near\;P_{cr}$) can fail by buckling instability during liquefaction. When lateral spreading took place in sloping grounds, lateral spreading increased lateral deflection of pile and reduced the buckling load, promoting more rapid collapse. In addition, buckling shape of pile was observed. In the ease of pile buckling, hinge formed at the middle of the pile, not at the bottom. And in sloping grounds, location of hinge got loiter compared with level ground because of the effects of lateral spreading.

  • PDF

국내 발생지진에 의한 물류창고 강재 적재설비의 내진성능 평가 (Seismic Performance of Steel Industrial Storage Racks Subjected to Korea Earthquakes)

  • 전종수;최형석;서영득;김충길;허광희
    • 한국지진공학회논문집
    • /
    • 제22권3호
    • /
    • pp.149-160
    • /
    • 2018
  • This study experimentally and analytically examines the seismic vulnerability of steel rack storage frames subjected to Korea earthquakes (2016 Gyeongju earthquake and 2017 Pohang earthquake). To achieve this aim, this study selects a three-story, one-bay steel rack frame with a typical configuration of rack frame in Korea. Firstly, the local behavior for frame components is examined by performing monotonic and/or cyclic load tests and the global response and dynamic characteristics of the subject rack frame are investigated by conducting a shaking table test. The analytical model of the rack frame is then created based on the experimental results and is used to perform nonlinear time history analyses with recorded Korea earthquakes. The seismic demand of the rack frame is considerably affected by the spectral acceleration response, instead of peak ground accelerations (peak floor accelerations). Moreover, the collapse fragility curve of the rack frame is developed using incremental dynamic analyses for the Gyeongju and Pohang earthquakes. Fragility results indicate that the ground motion characteristics of these earthquakes do not significantly affect the frame vulnerability at the collapse state.

진동대 시험을 이용한 중공블록 보강 기초의 내진성능분석 (Analysis on Seismic Resistance Capacity of Hollow Concrete Block Reinforced Foundation Ground by Using Shaking Table Test)

  • 신은철;이연정;양태철
    • 한국지반신소재학회논문집
    • /
    • 제20권4호
    • /
    • pp.85-93
    • /
    • 2021
  • 한반도의 70%는 산지로 구성되어 있으며, 서해와 남해의 수심은 상대적으로 얕은 편이다. 따라서, 공업단지, 주거단지, 항만 및 공항 부지를 위한 대규모 간척사업이 시행되고 있다. 매립지역의 일반적인 문제는 지반이 연약하여 지지력이 부족할 뿐만 아니라 상당한 침하가 발생된다는 것이다. 중공블록은 중·저층 아파트 또는 단층의 공장건물을 건설하기 위해 계획된 느슨한 연약기초 지반보강을 위해 사용된다. 최근 4.0~5.0의 강도를 가진 지진이 서쪽과 남동쪽 해안지역을 따라 발생하고 있다. Lee (2019)는 정적 지지력시험을 통해 얕은 기초보강 중공블록의 장점에 대하여 연구하였다. 이 연구에서 블록 내부에 쇄석으로 채움된 보강된 모래지반의 중공블록 동적거동은 진동대 1000 mm × 1000 mm 시험을 통해 연구하였다. 3가지 지진파인 Ofunato, Hachinohe, Artificial 지진파와 2가지 가속도(0.154g, 0.22g)를 진동대 시험에 적용하였다. 중공블록으로 보강된 지반 위의 구조물 수평변위는 LVDT를 사용하여 측정하였다. 중공블록에 의한 지반보강 효율을 평가하기 위하여 지반의 상대밀도를 45%, 65%, 85%로 각각 구성하였으며, 수평변위를 측정하고 한계수평변위 0.015h(건축물 내진등급기준, 2019)와 비교하였다. 중공블록으로 보강된 모래지반에 대한 진동대 시험 결과에 기반해서 벌집 모양의 중공블록은 블록내부에 쇄석 채움으로서 큰 구속력을 가지며, 중공블록의 내부 및 외부를 따라 발생하는 관입저항력으로 인한 큰 주면마찰력을 갖는 것으로 평가되었다. 이러한 모든 요소들은 진동대 시험 중에 수평변위를 상당이 줄이는 것으로 나타났다. 마지막으로, 중공블록 보강 지반은 지진파와 가속도에 상관없이 중·저층 건물의 얕은기초 보강공법으로 매우 우수함이 입증되었다.

중력하중 설계된 1:5 축소 3층 철근콘크리트 골조의 지진모의실험 (Earthquake Simulation Tests of A 1:5 Scale Gravity Load Designed 3-Story Reinforced Concrete Frame)

  • 이한선;우성우
    • 콘크리트학회지
    • /
    • 제10권6호
    • /
    • pp.241-252
    • /
    • 1998
  • 이 연구의목적은 여러 수준의 지진에 대한 비내진 상세를 가진 저층 모멘트 저항 골조의 실제 반응을 관찰하기 위한 것이다. 우선 모델에 대한 축소율은 사용된 진동대의 용량을 고려하여 1 : 5 로 결정하였으며 상사성의 법칙에 따라 모델을 제작하였다. 그 다음에 이 모델에 대해 Taft N21E 지진가속도 기록의 최대 지진가속도를 0.12g. 0.2g, 0.4g로 조정하여 진동대를 이용한 지진모의실험을 수행하였다. 각 층별 횡방향 가속도와 변위, 그리고 구조물의 취약부위에서 국부변형이 측정되었다. 밑면 전단력은 손수 만든 로드셀을 이용하여 측정하엿다. 각 지진모의실험 전과 후에는 고유주기와 감쇠비의 변화를 살펴보기 위해 자유진동실험을 수행하였다. 전체거동과 국부거동에 대한 실험결과를 분석한 결과, 이 모델은 우리나라의 현행 내진 설계 기준에서의 설계지진 즉, 0.12g의 최대 지진가속에 대해서는 선형탄성으로 거동하였다. 최대 밑면 전단력은 1.8tf 로 설계 밑면 전단력의 약 4.7배로나타났다.이 실험모델은 높은 수준의 지진모의실험에서도 양호한 성능을 나타내었다. 높은 수준의지진에 대한 저항의 주요요소는 1)높은 초과강도, 2)기본주기의 증가, 그리고 3)비탄성 변형에 의한 얼마간의 에너지소산이다. 이 실험에서 모델의 층간변위는 대략 허용한계 내에 있었다.