• 제목/요약/키워드: Lateral force resistance

검색결과 122건 처리시간 0.025초

Analytical modeling of masonry infills with openings

  • Kakaletsis, D.
    • Structural Engineering and Mechanics
    • /
    • 제31권4호
    • /
    • pp.423-437
    • /
    • 2009
  • In order to perform a step-by-step force-displacement response analysis or dynamic time-history analysis of large buildings with masonry infilled R/C frames, a continuous force-deformation model based on an equivalent strut approach is proposed for masonry infill panels containing openings. The model, which is applicable for degrading elements, can be implemented to replicate a wide range of monotonic force-displacement behaviour, resulting from different design and geometry, by varying the control parameters of the model. The control parameters of the proposed continuous model are determined using experimental data. The experimental program includes fifteen 1/3-scale, single-story, single-bay reinforced concrete frame specimens subjected to lateral cyclic loading. The parameters investigated include the shape, the size, the location of the opening and the infill compressive strength. The actual properties of the infill and henceforth the characteristics needed for the diagonal strut model are based on the assessment of its lateral resistance by the subtraction of the response of the bare frame from the response of the infilled frame.

Laser 반사측정법을 이용한 상악 전치부 함입시 저항중심의 수평적 위치에 관한 연구 (THE CENTER OF RESISTANCE OF THE MAXILLARY ANTERIOR SEGMENT IN THE HORIZONTAL PLANE DURING INTRUSION BY USING LASER REFLECTION TECHNIQUE)

  • 박기호;손병화
    • 대한치과교정학회지
    • /
    • 제23권4호
    • /
    • pp.619-631
    • /
    • 1993
  • Tooth movement by segment is one of the means which are frequently used in daily orthodontic practice. When we retract or intrude a tooth or teeth, we should recognize the center of resistance of the certain tooth or teeth. There have been many studies about the center of resistance of a single tooth, not so much was about the tooth-segment. At the present study the center of resistance of the maxillary anterior segment is experimentally investigated by using laser reflection technique and metal splints on the human dry skull. The variables of intrusive force magnitude are divided into two groups, 50g and 100g groups. The results were as follows ; 1. The center of resistance of the maxillary anterior segment composed of the central and lateral incisors was at the mesial portion of canine crown at the coronal level. 2. The center of resistance of the maxillary anterior segment composed of the central and lateral incisors and canines is between the canine and the 1st premolar crowns at the coronal level.

  • PDF

Experimental study on seismic behavior of two-storey modular structure

  • Liu, Yang;Chen, Zhihua;Liu, Jiadi;Zhong, Xu
    • Steel and Composite Structures
    • /
    • 제37권3호
    • /
    • pp.273-289
    • /
    • 2020
  • Due to the unique construction method of modular steel buildings (MSBs) with units prefabricated fully off the site and assembled quickly on the site, the inter-module connection for easy operation and overall performance of the system were key issues. However, it was a lack of relevant research on the system-level performance of MSBs. This study investigated the seismic performance of two-storey modular steel structure with a proposed vertical rotary inter-module connection. Three full-scale quasi-static tests, with and without corrugated steel plate and its combination, were carried out to evaluate and compare their seismic behaviour. The hysteretic performance, skeleton curves, ductile performance, stiffness degradation, energy dissipation capacity, and deformation pattern were clarified. The results showed that good ductility and plastic deformation ability of such modular steel structures. Two lateral-force resistance mechanisms with different layout combinations were also discussed in detail. The corrugated steel plate could significantly improve the lateral stiffness and bearing capacity of the modular steel structure. The cooperative working mechanism of modules and inter-module connections was further analyzed. When the lateral stiffness of upper and lower modular structures was close, limited bending moment transfer may be considered for the inter-module connection. While a large lateral stiffness difference existed initially between the upper and lower structures, an obvious gap occurred at the inter-module connection, and this gap may significantly influence the bending moments transferred by the inter-module connections. Meanwhile, several design recommendations of inter-module connections were also given for the application of MSBs.

Modified p-y curves to characterize the lateral behavior of helical piles

  • Hyeong-Joo, Kim;James Vincent, Reyes;Peter Rey, Dinoy;Tae-Woong, Park;Hyeong-Soo, Kim;Jun-Young, Kim
    • Geomechanics and Engineering
    • /
    • 제31권5호
    • /
    • pp.505-518
    • /
    • 2022
  • This study introduces soil resistance multipliers at locations encompassed by the zone of influence of the helix plate to consider the added lateral resistance provided to the helical pile. The zone of influence of a helix plate is a function of its diameter and serves as a boundary condition for the modified soil resistance springs. The concept is based on implementing p-multipliers as a reduction factor for piles in group action. The application of modified p-y springs in the analysis of helical piles allows for better characterization and understanding of the lateral behavior of helical piles, which will help further the development of design methods. To execute the proposed method, a finite difference program, HPCap (Helical Pile Capacity), was developed by the authors using Matlab. The program computes the deflection, shear force, bending moment, and soil resistance of the helical pile and allows the user to freely input the value of the zone of influence and Ω (a coefficient that affects the value of the p-multiplier). Results from ten full-scale lateral load tests on helical piles embedded at depths of 3.0 m with varying shaft diameters, shaft thicknesses, and helix configurations were analyzed to determine the zone of influence and the magnitude of the p-multipliers. The analysis determined that the value of the p-multipliers is influenced by the ratio between the pile embedment length and the shaft diameter (Dp), the effective helix diameter (Dh-Dp), and the zone of influence. Furthermore, the zone of influence is recommended to be 1.75 times the helix diameter (Dh). Using the numerical analysis method presented in this study, the predicted deflections of the various helical pile cases showed good agreement with the observed field test results.

토션 바 스프링을 적용한 일체형 도어체커 개폐력 해석 (Door Effort Analysis for Door Checker of Integrated Type with Torsion Bar Spring)

  • 윤상민;강성종
    • 한국기계가공학회지
    • /
    • 제11권3호
    • /
    • pp.86-91
    • /
    • 2012
  • Door effort was calculated for a new door checker with torsion bar spring and integrated checker case by FE analysis. A hybrid checker arm which has peaks and valleys only on the upper surface was adopted to reduce noise in operation and make operation with more distinctive steps. The checker arm was modeled using shell elements to estimate both the longitudinal and the lateral resistance force by checker arm. By combining the checker arm resistance force obtained from analysis and the door self-closing force by the theoretical calculation, door effort was predicted to show the good correlation with test results. In addition the unrolling effect of roller model was investigated and a new roller type for more smooth rolling was studied.

Integral Abutment Bridge behavior under uncertain thermal and time-dependent load

  • Kim, WooSeok;Laman, Jeffrey A.
    • Structural Engineering and Mechanics
    • /
    • 제46권1호
    • /
    • pp.53-73
    • /
    • 2013
  • Prediction of prestressed concrete girder integral abutment bridge (IAB) load effect requires understanding of the inherent uncertainties as it relates to thermal loading, time-dependent effects, bridge material properties and soil properties. In addition, complex inelastic and hysteretic behavior must be considered over an extended, 75-year bridge life. The present study establishes IAB displacement and internal force statistics based on available material property and soil property statistical models and Monte Carlo simulations. Numerical models within the simulation were developed to evaluate the 75-year bridge displacements and internal forces based on 2D numerical models that were calibrated against four field monitored IABs. The considered input uncertainties include both resistance and load variables. Material variables are: (1) concrete elastic modulus; (2) backfill stiffness; and (3) lateral pile soil stiffness. Thermal, time dependent, and soil loading variables are: (1) superstructure temperature fluctuation; (2) superstructure concrete thermal expansion coefficient; (3) superstructure temperature gradient; (4) concrete creep and shrinkage; (5) bridge construction timeline; and (6) backfill pressure on backwall and abutment. IAB displacement and internal force statistics were established for: (1) bridge axial force; (2) bridge bending moment; (3) pile lateral force; (4) pile moment; (5) pile head/abutment displacement; (6) compressive stress at the top fiber at the mid-span of the exterior span; and (7) tensile stress at the bottom fiber at the mid-span of the exterior span. These established IAB displacement and internal force statistics provide a basis for future reliability-based design criteria development.

고차모드 영향이 반영된 Pushover 해석을 위한 횡하중 분배계수 제안 (Lateral Load Distribution Factor for Modal Pushover Analysis)

  • 김건우;송진규
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2005년도 학술발표회 논문집
    • /
    • pp.236-243
    • /
    • 2005
  • Nonlinear static analysis is used to quantify the resistance of the structure to lateral deformation and to gauge the mode of deformation and intensity of local demands. A simple method for the nonlinear static analysis of complex building structures subjected to monotonically increasing horizontal loading(pushover analysis) is presented. The method is designed to be a part of new methodologies for the seismic design and evaluation of structures. A variety of existing pushover analysis procedures are currently being consolidated under programs such as ATC 40 and FEMA 273. And various techniques have been recommended, including the use of constant lateral force profiles and the use of adaptive and multimodal approaches. In this paper a modal pushover analysis using design response spectra of UBC 97 is proposed. Proposed method is compared against the method in FEMA 273 and ATC 40, and results of time history analysis.

  • PDF

경골목구조에서 구조재와 오에스비로 구성된 못 접합부의 인발 및 전단성능 (Withdrawal and Lateral Resistance of Nail Joints Composed of Dimension Lumber and OSB in Light-Frame Wood Construction)

  • 오세창
    • Journal of the Korean Wood Science and Technology
    • /
    • 제41권3호
    • /
    • pp.211-220
    • /
    • 2013
  • 경골목조건축에서 못 접합부는 수평하중을 지지하고 전달하도록 설계되지만, 바람으로 인한 상향력처럼 인발하중에 직면하기도 한다. 본 연구에서는 경골목조건축에서 일반적으로 사용되는 구조재와 덮개로 구성된 못 접합부에 대하여 인발성능과 2면 전단시험을 통해 인발 및 측방하중에 대한 내력성능을 시험하고 설계기준에 부합되는 가를 평가하였다. 인발하중에 대한 내력성능은 부재의 비중에 의해 크게 좌우되었으며 I형장선의 경우 낮은 밀도에도 불구하고 높은 인발성능을 나타내었다. 최대 인발하중은 기준허용 최대 인발하중보다 매우 높게 나타났다. 전단성능도 비중이 큰 낙엽송과 오에스비로 구성된 접합부가 비중이 작은 SPF와 오에스비로 구성된 접합부보다 높은 성능을 나타내었으며 모두 기준설계치보다 높은 성능을 나타내었다. 접합부의 변형은 주로 못의 휨 변형에 의한 것으로 나타났으며 SPF와 오에스비로 구성된 접합부에서의 못의 휨 변형이 현저하게 나타났다.

Lateral Resistance of CLT Wall Panels Composed of Square Timber Larch Core and Plywood Cross Bands

  • JANG, Sang Sik;LEE, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • 제47권5호
    • /
    • pp.547-556
    • /
    • 2019
  • Thinned, small larch logs have small diameters and no value-added final use, except as wood chips, pallets, or fuel wood, which are products with very low economic value; however, their mechanical strength is suitable for structural applications. In this study, small larch logs were sawed, dried, and cut into square timbers (with a $90mm{\times}90mm$ cross section) that were laterally glued to form core panels used to manufacture cross-laminated timber (CLT) wall panels. The surface and back of these core panels were covered with 12-mm-thick structural plywood panels, used as cross bands to obtain three-ply CLT wall panels. This attachment procedure was conducted in two different ways: gluing and pressing (CGCLT) or gluing and nailing (NGCLT). The size of the as-manufactured CLT panels was $1,220mm{\times}2,440mm$, the same as that of the plywood panels. The final wall panels were tested under lateral shear force in accordance with KS F 2154. As the lateral load resistance test required $2,440mm{\times}2,440mm$ specimens, two CLT wall panels had to be attached in parallel. In addition, the final CLT panels had tongued and grooved edges to allow parallel joints between adjacent pieces. For comparison, conventional light-frame timber shear walls and midply wall systems were also tested under the same conditions. Shear walls with edge nail spacing of 150 mm and 100 mm, the midply wall system, and the fabricated CGCLT and NGCLT wall panels exhibited maximum lateral resistances of 6.1 kN/m (100%), 9.7 kN/m (158%), 16.9 kN/m (274%), 29.6 kN/m (482%), and 35.8 kN/m (582%), respectively.

부유식 해상구조물의 계류를 위한 사질토 지반의 석션파일 설계 (Design for Installation of Suction Piles in Sand Deposits for Mooring of Floating Offshore Structures)

  • 박철수;이주형;백두현;도진웅
    • 한국지반공학회논문집
    • /
    • 제30권10호
    • /
    • pp.33-44
    • /
    • 2014
  • 본 연구에서는 국내 서남해 해상지역 시범사업의 부유식 콘크리트 해상구조물 계류를 위한 기초시스템으로서 석션파일을 적용하기 위한 예비설계를 수행하였다. 설계에 앞서 시범사업 대상지역인 서남해안에 대한 지반 및 수리 조건, 재현주기 100년의 환경외력 등 현장 조건을 면밀히 검토하였다. 석션파일은 설계하중에 대한 수평방향 지지력을 만족해야하고, 뿐만 아니라 지반종류 및 강도정수, 유효응력, 침투압 등의 조건에 따른 관입성 검토가 수행되어야 한다. 본 설계에서는 석션파일 직경에 따라 설계외력에 대해 수평방향 안정성을 확보할 수 있는 목표 침설깊이를 설정하고, 침설단계별로 상한석션압 이내에서 관입력과 관입저항력 비교를 통해 설계석션압을 산정하였다. 검토결과 직경 3.0~5.0m 석션파일의 경우 목표 깊이까지 침설이 불가능하였고, 직경 6.0m와 7.0m 석션파일은 각각 침설깊이 8.5m와 8.0m에서 수평방향 안정성 및 설계석션압에 의한 침설을 모두 만족함을 확인하였다.