• Title/Summary/Keyword: Lateral deviation

Search Result 251, Processing Time 0.027 seconds

Forefoot disorders and conservative treatment

  • Park, Chul Hyun;Chang, Min Cheol
    • Journal of Yeungnam Medical Science
    • /
    • v.36 no.2
    • /
    • pp.92-98
    • /
    • 2019
  • Forefoot disorders are often seen in clinical practice. Forefoot deformity and pain can deteriorate gait function and decrease quality of life. This review presents common forefoot disorders and conservative treatment using an insole or orthosis. Metatarsalgia is a painful foot condition affecting the metatarsal (MT) region of the foot. A MT pad, MT bar, or forefoot cushion can be used to alleviate MT pain. Hallux valgus is a deformity characterized by medial deviation of the first MT and lateral deviation of the hallux. A toe spreader, valgus splint, and bunion shield are commonly applied to patients with hallux valgus. Hallux limitus and hallux rigidus refer to painful limitations of dorsiflexion of the first metatarsophalangeal joint. A kinetic wedge foot orthosis or rocker sole can help relieve symptoms from hallux limitus or rigidus. Hammer, claw, and mallet toes are sagittal plane deformities of the lesser toes. Toe sleeve or padding can be applied over high-pressure areas in the proximal or distal interphalangeal joints or under the MT heads. An MT off-loading insole can also be used to alleviate symptoms following lesser toe deformities. Morton's neuroma is a benign neuroma of an intermetatarsal plantar nerve that leads to a painful condition affecting the MT area. The MT bar, the plantar pad, or a more cushioned insole would be useful. In addition, patients with any of the above various forefoot disorders should avoid tight-fitting or high-heeled shoes. Applying an insole or orthosis and wearing proper shoes can be beneficial for managing forefoot disorders.

DRIVER BEHAVIOR WITH ADAPTIVE CRUISE CONTROL

  • Cho, J.H.;Nam, H.K.;Lee, W.S.
    • International Journal of Automotive Technology
    • /
    • v.7 no.5
    • /
    • pp.603-608
    • /
    • 2006
  • As an important and relatively easy to implement technology for realizing Intelligent Transportation Systems(ITS), Adaptive Cruise Control(ACC) automatically adjusts vehicle speed and distance to a preceding vehicle, thus enhancing driver comfort and safety. One of the key issues associated with ACC development is usability and user acceptance. Control parameters in ACC should be optimized in such a way that the system does not conflict with driving behavior of the driver and further that the driver feels comfortable with ACC. A driving simulator is a comprehensive research tool that can be applied to various human factor studies and vehicle system development in a safe and controlled environment. This study investigated driving behavior with ACC for drivers with different driving styles using the driving simulator. The ACC simulation system was implemented on the simulator and its performance was evaluated first. The Driving Style Questionnaire(DSQ) was used to classify the driving styles of the drivers in the simulator experiment. The experiment results show that, when driving with ACC, preferred headway-time was 1.5 seconds regardless of the driving styles, implying consistency in driving speed and safe distance. However, the lane keeping ability reduced, showing the larger deviation in vehicle lateral position and larger head and eye movement. It is suggested that integration of ACC and lateral control can enhance driver safety and comfort even further.

HORIZONTAL PLANE JAW MOVEMENTS IN EDENTULOUS PATIENTS BY USE OF EXTRAORAL TRACING DEVICE (구외 묘기장치를 이용한 무치악 환자의 수평면상 하악운동에 관한 연구)

  • Eun Seong-Sik;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.32 no.3
    • /
    • pp.396-410
    • /
    • 1994
  • Ten subjects who were going to wear conventional complete dentures were selected for this study. Theree subjects were women and seven were men. The average age was 63.1 years(range : 44 to 76 years). With the Height tracer (extraoral tracing device) in place the subject was instructed to go through the entire range of mandibular movements. The extreme lateral pathway of the incisor point, the so-called Gothic arch, was thereby inscribed by the stylus on the tracing plate. The mandibular movements in this study were peformed voluntarily by the subject(self guided technique) and guided by the dentist(chin-point technique and bimanual technique). The Gothic arch tracings were analysed and the Gothic arch angles and eccentric movement distances were measured. The results were as follows : 1. The apex position of the Gothic arch tracings of mandibular movements in edentulous patients varied both anterioposteriorly and mediolaterally. 2. The Gothic arch tracing had some lateral deviation during protrusion. 3. The average Gothic arch tracing angle was $136.7{\pm}12.0^{\circ}$ by subjects self guided technique, $135.7{\pm}5.9^{\circ}$ by chin-point technique, $136.6{\pm}6.5^{\circ}$ by bimanual technique. But there were no statistical differences in the reliability among the three techniques. 4. The average mandibular eccentric movements were irregular and the mandibular eccentric movement distances varied with a wide range.

  • PDF

Physical Function of Patients with Amyotrophic Lateral Sclerosis (근위축성측삭경화증 환자의 신체적 기능 상태)

  • Lee, Yoon-Kyoung;Lim, Nan-Young;Kim, Seung-Hyun
    • Journal of muscle and joint health
    • /
    • v.13 no.2
    • /
    • pp.130-139
    • /
    • 2006
  • Purpose: This study was designed to present preliminary data for the development of appropriate nursing care system for the patients with ALS by analyzing their physical function. Method: The clinical data of 36 ALS patients, who visited ALS Clinic of H University Hospital in Seoul, were collected from January, 2006 to August, 2006. To determine the physical function, Norris ALS scale and Appel ALS Rating Scale were used. The data were analyzed by frequency, percentage, mean, standard deviation, range, t-test, ANOVA, using SPSS PC program. Results: The mean score of physical activity, muscle strength, upper extremity function, lower extremity function was 18.08, 27.72, 25.94, 25.19 respectively. There were significant differences in physical activity, muscle strength, and upper extremity function according to sender and comorbid disease(diabetes). Although sites of symptom onset were not statistically significant with all physical function, patients with bulbar onset showed relatively severe physical disabilities. Conclusion: The preliminary data on physical function of patients with ALS would be helpful for the development of ALS nursing guideline system.

  • PDF

Clinical Characteristics of Sound Dogs with Medial Patellar Luxation

  • Kim, Gi-Na;Jeong, Soon-Wuk
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • The purpose of this study is to identify clinical features of sound (non-lame) dogs with medial patellar luxation (MPL). Medical records of 72 dogs diagnosed with MPL were retrospectively reviewed. There were no significances in breed, sex, body weight, body condition score (BCS), osteoarthritis (OA) score, inclination of the femoral head angle (IFA), and mechanical medial proximal tibial angle (mMPTA) between sound and lame dogs, respectively. The mean age of sound dogs was significantly higher than that of lame dogs (P < 0.05), especially in MPL grade 3. The frequency of sound dogs with MPL grade 1 and 2 was 2.3 times higher than that of sound dogs with MPL grade 3 and 4 (P < 0.05). The anatomical lateral distal femoral angle (aLDFA) of sound dogs was significantly lower than that of lame dogs (P < 0.05). However, there were no statistical differences in aLDFA between sound and lame dogs in MPL grade 1, 2, and 4, except for MPL grade 3. This study suggests that in case of MPL grade 1 and 2, frequency of sound dogs is significantly high, and also that in MPL grade 3, if mean ± (standard deviation) age of the dogs is 7.4 ± 3.6 years old and the aLDFA is 105.6 ± 4.1 degrees, they are very highly possible to be sound dogs.

The Effects of Lateral Wedged Insole to the Shoe of the Affected Side on Weight Bearing, Balance and Gait with Stroke (마비측에 적용한 외측 쐐기 깔창이 뇌졸증 환자의 체중부하율과 균형, 보행에 미치는 영향)

  • Kim, Hye-Lim;Shin, Won-Seob
    • PNF and Movement
    • /
    • v.11 no.2
    • /
    • pp.21-29
    • /
    • 2013
  • Purpose : The study was to evaluate the weight distribution, balance and gait function of stroke patients wearing lateral wedged insole to the shoe of the affected side. Methods : 27 patients with stroke (15 men, 12 women) participated in this study. Participants performed weight distribution, dynamic balance and gait ability with or without wedged insole on affected side in a random order. The balancia was used to evaluate the weight distribution. Deviation from the center line was analyzed by Dartfish during sit to stand to evaluate dynamic balance. The functional walk ability evaluated by 10 m walking velocity. Results : The asymmetry index of weight bearing improved significantly with wedged insole of affected side(p<.05). During sit to stand, center of gravity significantly moved from non-affected side to more mid line of body(p<.05). Improvement were shown in walking speed after wearing the wedged insole(p<.05). Conclusion : Wedged insole applied on affected side have a beneficial effect on weight distribution, dynamic balance and walking speed with stroke.

Dose Distribution of Rectum and Bladder in Intracavitary Irradiation (자궁경부암 강내 방사선 조사장치에 의한 직장 및 방광의 피폭선량 평가)

  • Chu S. S.;Oh W. Y.;Suh C. O.;Kim G. E.
    • Radiation Oncology Journal
    • /
    • v.2 no.2
    • /
    • pp.261-270
    • /
    • 1984
  • The intrauterine irradiation is essential to achieve adequate tumor dose to central tumor mass of uterine malignancy in radiotherapy. The complications of pelvic organ are known to be directly related to radiation dose and physical parameters. The simulation radiation and medical records of 203 patients who were treated with intrauterine irradiation from Feb. 1983 to Oct. 1983, were critically analized. The physical parameters to include distances between lateral walls of vaginal fornices, longitudinal and lateral angles of tandem applicator to the body axis, the distance from the external os of uterine cervix to the central axis of ovoids were measured for low dose rate irradiation system and high dose rate remote control afterloading system. The radiation doses and dose distributions within cervical area including interesting points and bladder, rectum, according to sources arrangement and location of applicator, were estimated with personal computer. Followings were summary of study results ; 1. In distances between lateral walls of vaginal fornices, the low dose rate system showed as $4\~7cm$ width and high dose rate system showed as $5\~6cm$. 2. In horizontal angulation of tandem to body axis, the low dose rate system revealed mid position$64.6\%$, left deviation $19.2\%$and right deviation $16.2\%$. 3. In longitudinal angulation of tandem to body axis, the mid position was $11.8\%$ and anterior angulation $88.2\%$ in low dose rate system but in high dose rate system, anterior angulation was $98.5\%$. 4. Down ward displacement of ovoids below external os was only $3\%$ in low dose rate system and $66.7\%$ in high dose rate system. 5. In radiation source arrangement, the most activities of tandem and ovoid were 35 by 30 in low dose rate system but 50 by 40 in high dose rate system. 6. In low and high dose rate system, the total doses an4 TDF were 50, 70 Gy and 141, 123, including 40 Gy external irradiation. 7. The doses and TDF in interesting points Co, B, were 93, 47 Gy and 230, 73 in high dose rate system but in low doss rate system, 123, 52 Gy and 262, 75 respectively. 8. Doses and TDF in bladder and rectum were 70, 68 Gy and 124, 120 in low dose rate system, but in high dose rate system, 58, 64 Gy 98, 110 respectively, and then grades of injuries in bladder and rectum were 25, $30\%$ and 18, $23\%$ respectively.

  • PDF

The error analysis of field size variation in pelvis region by using immobilization device (고정기구의 사용이 골반부위 방사선조사영역의 변화에 미치는 오차분석)

  • Kim, Ki-Hwan;Kang, No-Hyun;Bim, Dong-Wuk;Kim, Jun-Sang;Jang, Ji-Young;Kim, Yong-Eun;Kim, Jae-Sung;Cho, Moon-June
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.31-36
    • /
    • 2000
  • In radiotherapy, it may happen to radiate surrounding normal tissue because of inconsistent field size by changing patient position during treatment. We are going to analyze errors reduced by using immobilization device with Electonic portal imaging device(EPID) in this study. We had treated the twenty-one patients in pelvic region with 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at supine position during treatment. They were separated to two groups, 11 patients without device and 10 patients with immobilization device. We used styrofoam for immobilization device and measured the errors of anterior direction for x, y axis and lateral direction for z, y axis from simulation film to EPID image using matching technique. For no immobilization device group, the mean deviation values of x axis and y axis are 0.19 mm. 0.48 mm, respectively and the standard deviations of systematic deviation are 2.38 mm, 2.19 mm, respectively and of random deviation for x axis and y axis are 1.92 mm. 1.29 mm, respectively. The mean deviation values of z axis and y axis are -3.61 mm. 2.07 mm, respectively and the standard deviations of systematic deviation are 3.20 mm, 2.29 mm, respectively and of random deviation for z axis and y axis are 2.73 mm. 1.62 mm, respectively. For immobilization device group, the mean deviation values of x axis and y axis are 0.71 mm. -1.07 mm, respectively and the standard deviations of systematic deviation are 1.80 mm, 2.26 mm, respectively and of random deviation for x axis and y axis are 1.56 mm. 1.27 mm, respectively. The mean deviation values of z axis and y axis are -1.76 mm. 1.08 mm, respectively and the standard deviations of systematic deviation are 1.87 mm, 2.83 mm, respectively and of random deviation for x axis and y axis are 1.68 mm, 1.65 mm, respectively. Because of reducing random and systematic error using immobilization device, we had obtained good reproducibility of patient setup during treatment so that we recommend the use of immobilization device in pelvic region of radiation treatment.

  • PDF

THE POSITIONAL RELATIONSHIP BETWEEN THE MANDIBLE AND THE HYOID BONE IN MANDIBULAR PROTRUSION AFTER ORTHOGNATHIC SURGERY EVALUATED WITH 3-D CT (3-D CT를 이용한 악교정술 전후의 하악과 설골의 위치에 관한 연구)

  • Lee, Sang-Han;Nam, Jeong-Hun;Jung, Chang-Wook;Kwon, Tae-Geon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.173-181
    • /
    • 2003
  • Purpose : This study was intended to evaluate the positional relationship between the hyoid bone and the mandible in patients with mandibular protrusion after mandibular set-back surgery by means of 3D-CT. Materials and methods : Preoperative(3 weeks before) and postoperative (6 weeks after) 3D-CT & cephalogram were taken on 32 patients(12 male, 20 female, mean age of 23.2) treated by bilateral sagittal split osteotomy with rigid fixation. The angular measurement on 3D-CT basilar view were deviation of Me & H, long axis angle of left & right cornu majus. The lineal measurement on 3D-CT basilar view were composed of intercondylar line and coordinates(x,y) of Me & H. The angular & lineal measurement of lateral cephalogram were composed of mandibular plane angle, SNA, SNB, ANB, FH-NA & FH-NB, and coordinates(x,y) of B, Pog, Me & H, PAS, Lpw, MPH and IAS. On the frontal cephalogram, deviation of Me were evaluated. Results : The mean mandibular set-back was 8.0mm horizontally and mandibular plane angle was slightly increased. The hyoid bone was displaced postero-inferiorly, the distance between MP(mandibular plane) and H(hyoid bone) was increased and the posterior airway space values (PAS, Lpw, IAS) were decreased. The coordinates Me(x,y), H(x,y) and deviation angle Me'& H' were revealed the strong positive correlation. Conclusion : The results revealed that the horizontal, vertical and transverse relationship of the mandibular and the hyoid bone movements were significantly correlated in patients performed mandibular set-back surgery.

Analysis of the Inter- and Intra-treatment Isocenter Deviations in Pelvic Radiotherapy With Small Bowel Displacement System (Small Bowel Displacement System을 이용한 골반부 방사선조사에서 치료간 및 치료중 중심점 위치변동에 관한 분석)

  • Kim Moon Kyung;Kim Dae Yong;Ahn Yong Chan;Huh Seung Jae;Lim Do Hun;Shin Kyung Hwan;Lee Kyu Chan
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.114-119
    • /
    • 2000
  • Purpose : To evaluate the e지ent and frequency of the inter- and intra-treatment isocenter deviations of the whole pelvis radiation field in using small bowel displacement system (SBDS). Methods and Materials : Using electronic portal imaging device (EPID), 302 postero-anterior 232 lateral portal images were prospectively collected from 11 patients who received pelvic radiation therapy (7 with cervix cancer and 4 with rectal cancer). All patients were treated in prone position with SBDS under the lower abdomen. Five metallic fiducial markers were placed on the image detection unit for the recognition of the isocenter and magnification. After aligning the bony landmarks of the EPID images on those of the reference image, the deviations of the isocenter were measured in right-left (RL), cranio-caudal (CC), and PA directions. Results : The mean inter-treatment deviation of the isocenter in each RL, CC, and PA direction was 1.2 mm ($\pm$ 1.6 mm), 1.0 mm ($\pm$3.0 mm), and 0.9 mm ($\pm$4.4 mm), respectively. Inter-treatment isocenter deviations over 5 mm and 10 mm in RL, CC, and PA direction were 2, 12, 24$\%$, and 0, 0, 5$\%$, respectively. Maximal deviation was detected in PA direction, and was 11.5 mm. The mean intratreatment deviation of the isocenter in RL, CC, and PA direction was 0 mm ($\pm$0.9 mm), 0.1 mm ($\pm$ 1.9mm), and 0 mm ($\pm$1.6 mm), respectively. All intra-treatment isocenter deviations over 5 mm in each direction were 0, 1, 1$\pm$, respectively. Conclusions : As the greatest and the most frequent inter-treatment deviation of the isocenter was along the PA direction, it is recommended to put more generous safety margin toward the PA direction on the lateral fields if clinically acceptable in pelvic radiotherapy with SBDD.

  • PDF