• 제목/요약/키워드: Lateral cephalometric radiograph

검색결과 27건 처리시간 0.019초

파노라마방사선사진상과 구외방사선사진상에서의 해부학적 구조에 관한 비교연구 (A COMPARATIVE STUDY OF ANATOMIC STRUCTURES ON THE PANORAMIC RADIOGRAPH AND SOME EXTRAORAL RADIOGRAPHS)

  • 이동규;김한평
    • 치과방사선
    • /
    • 제14권1호
    • /
    • pp.71-80
    • /
    • 1984
  • The author has studied each landmark for successful interpretation in the radiograph of the head that have the complex anatomic structures, using panoramic radiograph, postero-anterior cephalometric radiograph, lateral cephalometric radiograph, Waters' radiograph of the skull. The anatomic structures of the human dry skull attached by radiopaque materials were taken radiographs and analysed comparatively. The results were as follows: 1. The overall anatomic structures of the mandible showed sharp images in the panoramic radiograph than other radiographs with relatively less distortion, superimposition, blurring of the image. 2. The anatomic structures were situated on sagital plane of the skull showed blurred images in panoramic radiograph than other radiographs. 3. The anatomic structures which were situated on the basal portion of the skull showed blurred and secondary images in the panoramic radiograph than other radiographs. 4. In the panoramic radiograph, the lower 3rd portion of the orbit appeared to be superimposed with the superior portion of the maxillary sinus and the medial and lateral surface of the nasal cavity showed extensively superimposition of the orbit and the maxillary sinus, which images showed blurring. 5. The inferior surface and posterior surface of maxillary sinus showed to be good image in the panoramic radiograph than other radiographs. 6. In the panoramic radiograph, line of maxillary bone between lateral pterygoid plate, line of maxillary bone between zygomatic bone showed distinct image with another structures.

  • PDF

3-Dimensional analysis for class III malocclusion patients with facial asymmetry

  • Kim, Eun-Ja;Ki, Eun-Jung;Cheon, Hae-Myung;Choi, Eun-Joo;Kwon, Kyung-Hwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제39권4호
    • /
    • pp.168-174
    • /
    • 2013
  • Objectives: The aim of this study is to investigate the correlation between 2-dimensional (2D) cephalometric measurement and 3-dimensional (3D) cone beam computed tomography (CBCT) measurement, and to evaluate the availability of 3D analysis for asymmetry patients. Materials and Methods: A total of Twenty-seven patients were evaluated for facial asymmetry by photograph and cephalometric radiograph, and CBCT. The 14 measurements values were evaluated and those for 2D and 3D were compared. The patients were classified into two groups. Patients in group 1 were evaluated for symmetry in the middle 1/3 of the face and asymmetry in the lower 1/3 of the face, and those in group 2 for asymmetry of both the middle and lower 1/3 of the face. Results: In group 1, significant differences were observed in nine values out of 14 values. Values included three from anteroposterior cephalometric radiograph measurement values (cant and both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). In group 2, comparison between 2D and 3D showed significant difference in 10 factors. Values included four from anteroposterior cephalometric radiograph measurement values (both maxillary height, both body height) and six from lateral cephalometric radiographs (both ramus length, both lateral ramal inclination, and both gonial angles). Conclusion: Information from 2D analysis was inaccurate in several measurements. Therefore, in asymmetry patients, 3D analysis is useful in diagnosis of asymmetry.

디지털 측방두부규격방사선사진과 MDCT의 3차원 재구성 영상을 이용한 합성측방두부규격방사선사진의 계측치 비교 및 머리 위치가 미치는 효과 (Comparison of measurements from digital cephalometric radiographs and 3D MDCT-synthetized cephalometric radiographs and the effect of head position)

  • 김미자;최보람;허경회;이원진;허민석;이삼선;최순철
    • Imaging Science in Dentistry
    • /
    • 제39권3호
    • /
    • pp.133-147
    • /
    • 2009
  • Purpose : To investigate the reproducibilities and compare the measurements in digital and MDCT-synthesized cephalometric radiograph, and to investigate the effect of head position on the measurement during imaging with MDCT. Materials and Methods : Twenty-two dry skulls (combined with mandible) were used in this study. Conventional digital cephalometric radiograph was taken in standard position, and MDCT was taken in standard position and two rotated position ($10^{\circ}$ left rotation and $10^{\circ}$ right tilting). MDCT data were imported in $OnDemand^{(R)}$ and lateral cephalometric radiograph were synthesized from 3D virtual models. Two types of rotated MDCT data were synthesized with default mode and with corrected mode using both ear rods. For all six images, sixteen angular and eleven linear measurements were made in V-$Ceph^{(R)}$ three times. Reproducibility of measurements was assessed using repeated measures ANOV A and ICC. Linear and angular measurements were compared between digital and five MDCT-synthesized images by Student t-test. Results : All measurements in six types of cephalometric radiograph were not statistically different under ICC examination. Measurements were not different between digital and MDCT-synthesized images (P>.05). Measurements in MDCT-synthesized image in $10^{\circ}$ left rotation or $10^{\circ}$ right tilting position showed possibility of difference from digital image in some measurements, and possibility of improvement via realignment of head position using both ear rods. Conclusion : MDCT-synthesized cephalometric radiograph can substitute conventional cephalometric radiograph. The error on head position during imaging with MDCT have possibility that can produce measurement errors with MDCT-synthesized image, and these position error can be corrected by realignment of the head position using both ear rods.

  • PDF

디지털 및 일반 측방두부규격방사선사진에서 측정 방법에 따른 계측치의 비교 (The comparison of cephalometric measurements between measuring methods in digital and conventional lateral cephalometric radiograph)

  • 김미자;허경회;이원진;허민석;이삼선;이진구;안병근;최순철
    • Imaging Science in Dentistry
    • /
    • 제35권1호
    • /
    • pp.15-23
    • /
    • 2005
  • Purpose : To compare cephalometric measurement between measuring methods in digital and conventional lateral cephalometric radiograph. Materials and Methods : Twenty digital and conventional lateral cephalometric radiographs were selected. In digital group, cephalometric measurements were performed manually using hardcopies and automatically using $V-Ceph^{TM}$ program on the monitor. In conventional group, the same measurements were performed manually on conventional films, and for automatic measurement conventional films were digitized by scanner. All measurements were performed twice by 4 observers, and 24 cephalometric variables were calculated and the time spent for each measurement was recorded. The differences in measurements data and the time spent for each measurement were compared within each group. Intra-observer and inter-observer comparisons were performed. Results : In both groups, no statistically significant difference between manual and automatic measurements was observed and most of the variables didn't show statistically significant differences between methods. The observer with less experience tended to show statistically significant differences of measurements between methods, and differences from other observers. The differences of measurements between methods in digital group were lesser than those of conventional group with statistical significance in 8 variables out of 24. With automatic method and in digital group, the spent time was shorter. Conclusion : With direct digital radiograph, automatic method using manually idenitified landmarks can be preferable in cephalometric analysis. (Korean J Oral Maxillofac Radiol 2005; 35 : 15-23)

  • PDF

측방 두부규격방사선사진에서 발견되는 목덜미인대 골화에 관한 연구 (Study on the nuchal ligament ossification on lateral cephalometric radiograph)

  • 안창현
    • Imaging Science in Dentistry
    • /
    • 제39권1호
    • /
    • pp.7-11
    • /
    • 2009
  • Purpose: The purpose of this study was to assess the prevalence and radiographic characteristics of the nuchal ligament ossification on lateral cephalometric radiographs in Koreans. Subjects and Method: I review and interpreted the lateral cephalometric radiographs from 4,558 patients (1,857 males and 2,701 females, age range from 2 to 79 years) who visited the Kyungpook National University Dental Hospital from January 1, 2008 to February 3, 2009. I grouped the shapes of nuchal ligament ossification as round, rod-like, and segmented shape. And localized the ossification as the involvement of anterior cervical vertebral body. The data were analyzed by using chi-squared test with two-tailed and at a 5% significance level. Results: Among those who showed the nuchal ligament ossification, he mean age of the 143 males was 51.1 and that of the 97 females was 48.0 years. It as not observed completely below teens, and was observed 1% in twenties, 6.1% in thirties, 18.6% in forties, and 26.3% over fifties. It was significantly prevalent in older age group (P<0.01) and in males than females among the same age group (P<0.05). The shapes of nuchal ligament ossification were as follows in order of frequency: rod-like (49.2%), round (30.4%), and segmented (20.4%). The highest involvement of ossification as found at the level of C5 (67.9%), C4 (29.2%), C6 (22.9%), C3 (3.3%), C7 (2.9%), C2 (0.8%), and C1 (0.4%). Conclusion: The nuchal ligament ossifications on lateral cephalometric radiographs were showed as round, rod-like, or segmented shape. The nuchal ligament ossification is often observed after the age of 40 and is observed more frequently in males than females. The highest shape of nuchal ligament ossification was rod-like shape and the highest involvement of cervical spine was C5.

  • PDF

Patient radiation dose and protection from cone-beam computed tomography

  • Li, Gang
    • Imaging Science in Dentistry
    • /
    • 제43권2호
    • /
    • pp.63-69
    • /
    • 2013
  • After over one decade development, cone beam computed tomography (CBCT) has been widely accepted for clinical application in almost every field of dentistry. Meanwhile, the radiation dose of CBCT to patient has also caused broad concern. According to the literature, the effective radiation doses of CBCTs in nowadays market fall into a considerably wide range that is from $19{\mu}Sv$ to $1073{\mu}Sv$ and closely related to the imaging detector, field of view, and voxel sizes used for scanning. To deeply understand the potential risk from CBCT, this report also reviewed the effective doses from literatures on intra-oral radiograph, panoramic radiograph, lateral and posteroanterior cephalometric radiograph, multi-slice CT, and so on. The protection effect of thyroid collar and leaded glasses were also reviewed.

External root resorption after orthodontic treatment: a study of contributing factors

  • Jung, Yun-Hoa;Cho, Bong-Hae
    • Imaging Science in Dentistry
    • /
    • 제41권1호
    • /
    • pp.17-21
    • /
    • 2011
  • Purpose : The purpose of this study was to examine the patient- and treatment-related etiologic factors of external root resorption. Materials and Methods : This study consisted of 163 patients who had completed orthodontic treatments and taken the pre- and post-treatment panoramic and lateral cephalometric radiographs. The length of tooth was measured from the tooth apex to the incisal edge or cusp tip on the panoramic radiograph. Overbite and overjet were measured from the pre- and post-treatment lateral cephalometric radiographs. The root resorption of each tooth and the factors of malocclusion were analyzed with an analysis of variance. A paired t test was performed to compare the mean amount of root resorption between male and female, between extraction and non-extraction cases, and between surgery and non-surgery groups. Correlation coefficients were measured to assess the relationship between the amount of root resorption and the age in which the orthodontic treatment started, the degree of changes in overbite and overjet, and the duration of treatment. Results : Maxillary central incisor was the most resorbed tooth, followed by the maxillary lateral incisor, the mandibular central incisor, and the mandibular lateral incisor. The history of tooth extraction was significantly associated with the root resorption. The duration of orthodontic treatment was positively correlated with the amount of root resorption. Conclusion : These findings show that orthodontic treatment should be carefully performed in patients who need the treatment for a long period and with a pre-treatment extraction of teeth.

측모 두부 방사선사진과 컴퓨터 영상사진 (Dolphin Imaging System)의 계측치 에 관한 비교 (COMPARISONS OF MEASUREMENTS OBTAINED FROM LATERAL CEPHALOMETRIC RADIOGRAPHS AND DIGIGRAPHS OF DOLPHIN IMAGING SYSTEM)

  • 박해준;박영철
    • 대한치과교정학회지
    • /
    • 제24권3호
    • /
    • pp.521-534
    • /
    • 1994
  • The purpose of this study was to compare the differences in measurements between cephalometric radiographs and digigraphs of Dolphin Imaging System. 26 Korean adult male and 24 adult female with normal occlusion were selected. For each subject lateral cephalogram was taken. Digitizing with Digigraph Work Station of Dolphin in System. was performed as well. 50 tracings and 50 digigraphs were analyzed with Yonsei, Ricketts, Burstone analyses. The comparable measurements between tracing group and digigraph group were statistically analyzed. The results were as follows: 1. 13 of 64 comparable measurements did not show any statistically significant difference (P>0.05) between tracing group and digigraph group. 2. Three of the measurements with FH plane as a reference plane did not show any statistically insignificant difference. All measurement with SN plane as a reference plane showed statistically significant difference(p<0.05). 3. The measurements which showhed no statistically significant difference were mostly short distance linear measurements while most of the angular measurements showed statistically significant difference(p<0.05).

  • PDF

Sagittal split ramus osteotomy, intraoral vertical ramus osteotomy, and lateral corticectomy for asymmetric mandibular prognathism

  • Lee, Joo Young;Han, Se Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권4호
    • /
    • pp.249-256
    • /
    • 2021
  • Objectives: The purpose of this study was to evaluate the postoperative anteroposterior stability and improvements in facial asymmetry after performing LeFort I osteotomy in the maxilla, sagittal split ramus osteotomy (SSRO) and intraoral vertical ramus osteotomy (IVRO) in the mandible, and lateral corticectomy on the IVRO side. Materials and Methods: From July 2009 to October 2018, a retrospective analysis was performed on 11 subjects. Lateral cephalometric radiograph was performed preoperatively (T0), postoperatively (T1), and at 12 months of follow-up (T2), and the B point distance was measured. Posteroanterior cephalometric radiograph was performed preoperatively (S0) and at 12 months of follow-up (S1) and was used to measure five indicators (Ag angle, M-Ag, Co-Ag, Co-Me, and Ag-Me) of facial asymmetry. Results: The B point distances for T0 and T1 were significantly different (P=0.007), whereas those for T1 and T2 were not significantly different (P=0.1). In addition, there was a significant difference between the B point distances of T2 and T0 (P=0.026). Comparison of the facial asymmetry indicators before and after surgery showed a significant difference for all indicators between S0 and S1: the P-values of Ag angle, M-Ag, Co-Ag, Co-Me, and Ag-Me were 0.003, 0.003, 0.008, 0.006, and 0.004, respectively. The Z value was based on negative ranks. Conclusion: There was no significant difference in the B point distances from postoperation to the 12-month follow-up. However, there were significant differences in all five indicators related to facial asymmetry before and after surgery. The values for the five indicators of facial asymmetry all increased postoperatively.

성인 구개부 측모두부계측방사선 사진과 3D model의 골두께 비교 (Comparison of palatal bone thickness between 3D model and lateral cephalometric radiograph)

  • 장민국;이진우;차경석;정동화;이상민
    • 대한치과교정학회지
    • /
    • 제41권5호
    • /
    • pp.312-323
    • /
    • 2011
  • 본 연구는 동일한 환자에서 촬영한 측모두부계측방사선 사진과 전산화단층촬영 영상을 비교하여 미니 임플랜트 식립 시 측모두부계측방사선 사진을 통해 상악 구개부 골두께를 예측하기 위한 목적으로 시행되었다. 안모가 양호한 정상교합자 남녀 총 30명의 전산화단층촬영 영상을 3D model로 변환하고 측모두부계측방사선 사진과 동일부위의 골두께를 계측하기 위하여 프랑크프루트 평면에 대해 수직이고 상악 제2소구치와 제1대구치 인접면을 지나는 기준평면을 설정한다. 3D model에서 횡적으로 2 mm 간격으로 11개 부위의 구개부 골두께를 계측하고 측모두부계측방사선 사진과 비교하여 다음과 같은 결과를 얻었다. 3D model에서 골두께는 남녀 모두 정중구개부위에서 가장 컸고 측방으로 멀어질수록 작아지다가 남성는 측방 6 mm 여성는 측방 8 mm 부위에서 가장 최소값을 보인 후 다시 커지는 양상이 관찰되었다. 측모두부방사선 사진상 골두께는 남성이 $4.21{\pm}1.03mm$, 여성은 $2.71{\pm}1.62mm$로 남성이 여성보다 유의성 있게 컸다. 측모두부계측방사선 사진상 골두께와 3D model에서 횡적인 부위별로 측정한 골두께는 남성은 정중구개부와 측방 2 mm 부위를 제외한 나머지 부위에서 유의성 있는 상관관계를 보였고 여성은 모든 부위에서 유의성 있는 상관관계를 보였다. 또한 측모두부계측방사선 사진상 골두께와 3D model에서 상관관계를 보이는 부위에 대하여 회귀분석을 시행하였다. 이상의 횡적인 부위별 회귀분석을 통해 미니 임플랜트 식립 시 안전한 스크류의 길이를 결정하기 위한 골두께 예측에 도움이 될 것이다.