• Title/Summary/Keyword: Lateral arm

Search Result 154, Processing Time 0.024 seconds

Sensory Function Recovery by Free Tissue Transfer in the Extremities (사지에서 유리 조직 이식술에 의한 감각 기능 회복)

  • Lee, Jun-Mo;Kim, Kwon-Il;Hwang, Byung-Yun
    • Archives of Reconstructive Microsurgery
    • /
    • v.14 no.1
    • /
    • pp.14-17
    • /
    • 2005
  • Purpose: Authors have performed free tissue transplantation in the upper and lower extremities with sensory flaps and evaluated the sensory function recovery. Materials and methods: Between 1992 through 2004, sensory free flap articles published in the journal of the Korean microsurgical society, were reviewed and recovery of sensory function was assessed by static two-point discrimination test. Results: Static two point discrimination test showed average 6.7 mm in the thumb, average 12 mm in the hand and 7 cm of the dorsalis pedis flap, 20.5 mm of the lateral arm flap and over 8 cm of the forearm flap in the foot. Conclusion: Sensory flaps provide the protective and useful coverage in the upper and lower extremities and have benefit for activities for daily life in free tissue transferred patients.

  • PDF

Analyzing Materials Property using Optical Sensing Technique of Stabilizer Link for Automobile Parts (수송기계용 Stabilizer Link의 광센서를 이용한 부품성능평가)

  • Nam, K.W.;Woo, Y.M.;Oh, J.H.;Moon, C.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.6
    • /
    • pp.47-53
    • /
    • 2010
  • A stabilizer link connects the stabilizer bar to the lower arm of the suspension. When a vehicle is turning, lateral forces from the tire are transmitted through the stabilizer link into the stabilizer bar. The stabilizer bar will twist, thus adding rigidity to the vehicle body. In this study, the stabilizer link body was manufactured by using composite material with POM-GF25%. Therefore, the strength evaluation of stability link body with composite material carried out from tensile, wear and fatigue test. The tensile strength between the stability link body with composite material and the rod with knurling was the largest of four types of rod. In Analyzing materials property using optical sensing technique of stabilizer link for automobile parts, its has been identified the safety.

Local TIGRESS Simulations of Star Formation in Spiral Galaxies

  • Kim, Woong-Tae;Kim, Chang-Goo;Ostriker, Eve C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.46 no.1
    • /
    • pp.51.1-51.1
    • /
    • 2021
  • Spiral arms greatly affect gas flows and star formation in disk galaxies. We use local 3D simulations of vertically-stratified, self-gravitating, gaseous disks under a stellar spiral potential to study the effects of spiral arms on galactic star formation as well as formation of gaseous spurs/feathers. We adopt the TIGRESS framework to handle radiative heating and cooling, star formation, and ensuing supernova (SN) feedback. We find that more than 90% of star formation takes place inside spiral arms. The global star formation rate (SFR) in models with spiral arms is enhanced by less than a factor of 2 compared to the no-arm counterpart. This supports the picture that spiral arms do not trigger star formation but rather redistribute star-forming regions. Correlated SN feedback produces interarm feathers in both magnetized and unmagnetized models. These feathers live short, have parallel magnetic fields along their length, and are bounded by SN feedback in the lateral direction, in contrast to instability-induced feathers formed in our previous isothermal simulations.

  • PDF

Clinical Results of Lateral-Posterior Internal Fixation for the Treatment of Scapular Body Fractures (견갑골 체부 골절에서 외측 후방 금속판 고정술의 치료 결과)

  • Lee, Yoon-Min;Yeo, Joo-Dong;Song, Seok-Whan
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.1
    • /
    • pp.46-53
    • /
    • 2020
  • Purpose: Scapular body fractures have generally been treated with non-surgical methods. This study reports the clinical and radiological outcomes after lateral-posterior internal fixation for treating displaced scapular body fractures. Materials and Methods: From March 2007 to May 2017, out of 40 patients who underwent internal fixation for scapular fractures, 13 cases of lateral plate fixation of a scapular body fracture were reviewed retrospectively. Preoperative and postoperative displacement, angulation and glenopolar angle (GPA) were measured. The range of shoulder motion, visual analogue scale (VAS), and disabilities of the arm, shoulder, and hand (DASH), and Constant score were assessed at the last follow-up. Results: The mean follow-up period was 17.7 months (range, 6-45 months). The mean preoperative GPA was 23.3°±3.96° (range, 17.8°-28.1°) and the postoperative GPA was 31.1°±4.75° (range, 22.5°-40.1°). Injury to the suprascapular nerve, nonunion, fracture redisplacement, metallic failure, or infection did not occur. At the last follow-up, the mean range of motion was 150.5°±19.3° in forward flexion, 146.6°±2.34° in lateral abduction, 66.6°±19.1° in external rotation, and 61.6°±18.9° in internal rotation. The VAS, DASH, and Constant scores were 1.7±1.3, 6.2±2.4, and 86±7.9 points, respectively. Conclusion: A scapular body fracture with severe displacement, angulation and marked decreased GPA can be stabilized by lateralposterior plate fixation using the appropriate surgical technique with good functional and radiological results.

A Comparative Analysis between Several Crutch-Length-Estimation Techniques and Ideal Crutch Length (이상적인 목발 길이와 목발 길이 추정법들간의 비교)

  • Kim, Min-Jung;Park, Yun-Soo;Yi, Chung-Hwi;Kim, Hyun-Ae
    • Physical Therapy Korea
    • /
    • v.3 no.1
    • /
    • pp.24-31
    • /
    • 1996
  • The purpose of this study was to determine which of several crutch-fitting techniques best predicts ideal crutch length. Ideal crutch length is defined as the length of the crutch, including accessories, obtained during stance when the crutch tip is 6 inches (15.2 cm) lateral and 6 inches(15.2 cm) anterior to the fifth toe and the axillary pad is 2.5 inches(6.4 cm) below the axillary fold. Forty four volunteers were measured for crutches using each of the following methods:(1) 77% of actual height, (2) actual height minus 40.6 cm, (3) actual height minus 45.7 cm, (4) olecranon to opposite third finger tip, (5) olecranon to opposite fifth finger tip, (6) 77% of arm span, (7) arm span minus 40.6 cm, (8) anterior axillary fold to heel plus 5.1 cm, (9) anterior axillary fold to heel plus 10.2 cm, (10) ideal crutch length. Of the techniques studied, the two involving anterior axillary fold to heel were found to be good predictors: anterior axillary fold to heel plus 5.1 cm and anterior axillary fold to heel plus 10.2 cm. Finally, two additional length estimates were derived using linear regression analyses. These estimates provided the best overall predictors based on anterior axillary fold to heel and actual height.

  • PDF

An Analysis of location of Needle Entry Point and Palpated PSIS in S1 Nerve Root Block

  • Kim, Shin-Hyung;Yoon, Kyung-Bong;Yoon, Duck-Mi;Choi, Seong-Ah;Kim, Eun-Mi
    • The Korean Journal of Pain
    • /
    • v.23 no.4
    • /
    • pp.242-246
    • /
    • 2010
  • Background: The first sacral nerve root block (S1NRB) is a common procedure in pain clinic for patients complaining of low back pain with radiating pain. It can be performed in the office based setting without C-arm. The previously suggested method of locating the needle entry point begins with identifying the posterior superior iliac spine (PSIS). Then a line is drawn between two points, one of which is 1.5 cm medical to the PSIS, and the other of which is 1.5 cm lateral and cephalad to the ipsilateral cornu. After that, one point on the line, which is 1.5 cm cephalad to the level of the PSIS, is considered as the needle entry point. The purpose of this study was to analyze the location of needle entry point and palpated PSIS in S1NRB. Methods: Fifty patients undergoing C-arm guided S1NRB in the prone position were examined. The surface anatomical relationships between the palpated PSIS and the needle entry point were assessed. Results: The analysis revealed that the transverse and vertical distance between the needle entry point and PSIS were $28.7{\pm}8.8mm$ medially and $3.5{\pm}14.0mm$ caudally, respectively. The transverse distance was $27.8{\pm}8.3mm$ medially for male and $29.5{\pm}9.3mm$ medially for female. The vertical distance was $1.0{\pm}14.1mm$ cranially for male and $8.1{\pm}12.7mm$ caudally for female. Conclusions: The needle entry point in S1NRB is located on the same line or in the caudal direction from the PSIS in a considerable number of cases. Therefore previous recommended methods cannot be applied to many cases.

Changes of Impact Variables by the Change of Golf Club Length (골프 클럽에 따른 타격자세의 변화)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.181-189
    • /
    • 2005
  • To know the proper impact posture and changes for the various clubs, changes of impact variables according to the change of golf club length was investigated. Swing motions of three male low handicappers including a professional were taken using two high-speed video cameras. Four clubs iron 7, iron 5, iron 3 and driver (wood 1) were selected for this experiment. Three dimensional motion analysis techniques were used to get the kinematical variables. Mathcad and Kwon3D motion analysis program were used to analyze the position, distance and angle data in three dimensions. Major findings of this study were as follows. 1. Lateral position of the head remained more right side of the target up to 3.5cm compared to the setup as the length of the club increased. 2. Left shoulder raised up to 5cm and right shoulder lowered up to 2.5cm compared to setup. The shoulder line opened slightly (maximum 11 degrees) to the target line. 3. Forward lean angle of the trunk decreased up to 4 degrees (more erected) compared to setup. 4. Side lean angle of the trunk increased compared to setup and increased up to 16 degrees as the club length increased. 5. The pelvis moved to the target line direction horizontally and opened up to 31 degrees. Right hip moves laterally to the grip position at the setup. 6. Flexion of the left leg maintained almost constantly but the right leg flexed up to 11 degrees compared to setup. 7. Left arm is straightened but the right arm flexed about 20degrees compared to straight. 8. Center of the shoulders were in front of the knees and toes of the feet. 9. Hands moved to the left (8.7cm), forward (5.7cm) and upward (11.6cm) compared to the setup. This is because of the rotation of pelvis and shoulders. 10. Shaft angle to the ground was smaller than the lie angle of the clubs but it increased close to the lie of the clubs at impact.

The New Radiographic Evaluation of Hindfoot Alignment (후족부 정렬의 새로운 방사선학적 평가 방법)

  • Han, Woo-Yeon;Lee, Ho-Seong;Kim, Won-Kyeong;Ahn, Ji-Yong
    • Journal of Korean Foot and Ankle Society
    • /
    • v.16 no.3
    • /
    • pp.169-174
    • /
    • 2012
  • Purpose: There are various methods proposed for the evaluation of the hindfoot alignment. However, due to structural calcaneus variances between patients, it is hard to assess this alignment definitively. Thus, this study proposes a new method for evaluating of the hindfoot alignment and its comparisons to the existing current methods. Materials and Methods: This study includes simple weight bearing hindfoot coronal view radiographs of 120 patients, taken between the time period of March 2008 to November 2009. Among the 120 patients, there was a 1:1 ratio of male to female with an average age of 40. The newly proposed method for evaluating this alignment is to draw a moment arm from the point where the sustentaculum tali meets the medial calcaneus border to the most prominent aspect of the lateral process of the calcaneal tuberosity. The angle produced via the intersection of this moment arm to the mid-longitudinal axis of the tibia is found and used to evaluate the hindfoot alignment. The inter and intra-observer reliability was evaluated using the coefficient of intraclass correlation. This study also investigates the comparisons between the newly proposed method to the traditionally used Saltzman et al hindfoot alignment evaluating technique. Results: The newly proposed method has higher inter and intra-observer reliability than the existing traditional Saltzman et al technique. Conclusion: This new method is recommended over the traditionally used Saltzman et al technique as it has a stronger confidence level and is appropriate for assessing hindfoot alignment in simple radiographs.

Long-Term Clinical and Radiologic Outcomes of Minimally Invasive Posterior Cervical Foraminotomy

  • Kwon, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.3
    • /
    • pp.224-229
    • /
    • 2014
  • Objective : To report long-term clinical and radiological outcomes of minimally invasive posterior cervical foraminotomy (MI-PCF) performed in patients with unilateral single-level cervical radiculopathy. Methods : Of forty-six patients who underwent MI-PCF for unilateral single-level radiculopathy between 2005 and 2013, 33 patients were included in the study, with a mean follow-up of 32.7 months. Patients were regularly followed for clinical and radiological assessment. Clinical outcome was measured by visual analogue scale (VAS) for the neck/shoulder and arm, and the neck disability index (NDI). Radiological outcome was measured by focal/global angulation and disc height index (DHI). Outcomes after MI-PCF were evaluated as changes of clinical and radiological parameters from the baseline. Mixed effect model with random patients' effect was used to test for differences in the clinical and radiological parameters repeat measures. Results : There were no complications and all patients had an uneventful recovery during the early postoperative period. VAS scores for neck/shoulder and arm improved significantly in the early postoperative period (3 months) and were maintained with time (p<0.001). NDI improved significantly post-operatively and tended to decrease gradually during the follow-up period (p<0.001). There were no statistically significant changes in focal and global angulation at follow-up. Percent DHIs of the upper adjacent or operated disc were maintained without significant changes with time. During the follow-up, same site recurrence was not noted and adjacent segment disease requiring additional surgery occurred in two patients (6%) on the contra-lateral side. Conclusion : MI-PCF provides long-term pain relief and functional restoration, accompanied by good long-term radiological outcome.

Analysis of Overall Setup Accuracy Using On-Board Imager�� (온-보드 영상장치를 이용한 총체적 셋업의 정확성 분석)

  • Ma, Sun-Young;Lim, Sang-Wook;Kang, Soo-Man;Jeung, Tae-Sig
    • Progress in Medical Physics
    • /
    • v.22 no.2
    • /
    • pp.67-71
    • /
    • 2011
  • We evaluated the overall setup accuracy for the On-Board Imager (OBI, Varian Medical Systems Inc., Palo Alto, CA, USA), with attention to the laser, the gantry, and operator performance. We let experienced technicians place the marker block on the couch using a lock bar system, with alignment to the isocenter of the laser, every morning. A pair of radiographic images of the marker block was acquired at $0^{\circ}$ and $270^{\circ}$ angles to the kV arm to correct the position using a 2D/2D matching technique. Once the desired match was achieved, the couch was moved remotely to correct the setup error and the parameters were saved. The average for the vertical and the longitudinal displacements were 0.65 mm and 0.66 mm, and 0.01 mm for the lateral displacement. The average for the vertical and longitudinal displacements were statistically significant at the 0.05 level (p value=0.000 for both), while the p value for the lateral direction was 0.829. These results show that the tendencies to displacement in vertical and longitudinal directions occur through systematic error, while systematic error was not found in the lateral displacement. This daily overall evaluation is practical and easy to find the systematic and random errors in the setup system; however, a daily QA for laser and OBI alignment is still needed to minimize the systematic error in aligning patients.