• Title/Summary/Keyword: Lateral Air Gap

Search Result 18, Processing Time 0.025 seconds

Ultra Slim U-I & W-I Primary and Pick-up Coil Design for OLEV (온라인 전기자동차용 초박형의 U-I형 및 W-I형 급집전코일 설계)

  • Lee, Sung-Woo;Park, Chang-Byung;Cho, Jung-Goo;Cho, Gyu-Hyeong;Rim, Chun-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.274-282
    • /
    • 2011
  • The ultra slim U-I and W-I primary and pick-up coils for OLEV (On-Line Electric Vehicles) are proposed. With the proposed structures, the amount and the cost of the core are dramatically reduced. Not only air gap but also the lateral displacement are improved. The proposed structures are applied to the OLEV bus and SUV, which achieve 83% efficiency at 17cm air gap with more than 60kW output power, and the construction cost is lower than ₩300M/km. The proposed coil structures are verified with simulations and experiments.

Study on Running Safety of EMS-Type Maglev Vehicle Traveling over a Switching System (상전도흡인식 도시형 자기부상열차의 분기기 주행안전성 연구)

  • Han, Jong-Boo;Lee, Jong Min;Han, Hyung-Suk;Kim, Sung-Soo;Yang, Seok-Jo;Kim, Ki-Jung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.11
    • /
    • pp.1309-1315
    • /
    • 2014
  • The switch for a maglev vehicle should be designed such that the vehicle safely changes its track without touching the guiderail. In particular, a medium-to-low-speed EMS -type maglev train relies heavily on a U-type electromagnet where it generates levitation force and guidance force simultaneously. Therefore, it is necessary to evaluate the safety of the vehicle whenever it passes the switch, as it lacks active control of the guidance force. Furthermore, when the vehicle passes a segmented switch, which is a group of curves made up of connected lines with a small radius of curvature, it may come into mechanical contact with the guiderail owing to the excessive lateral displacement of the electromagnet. The goal of this study is to analyze the influence of a segmented switch on the safety of major design-related variables for achieving improved running safety. We propose a three-dimensional multibody dynamics model composed of two cars with one body. Using the proposed model, we perform a simulation of the lateral air gap, which is one of the measurements of the running safety of the vehicle when it passes the switch. The analyzed design variables are the length between short span girder, the articulation angle, the length between two centers of a fixed girder at its ends, and the number of girders. On the basis of the effects of the considered design variables, we establish an optimized design of a switch with improved safety.

Development Status and Test Results of the 3 way Switch for the Urban Maglev (도시형 자기부상열차 3방향 분기기 개발현황 및 시험결과)

  • Lee, Jong-Min;Han, Hyung-Suk;Kim, Chang-Hyun;Shin, Hyeon-Jae;Suh, Sung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1742-1749
    • /
    • 2011
  • The 3 way segmented Maglev switch is developed for the urban Maglev vehicle, which is scheduled to debut at the middle of 2013 in Incheon International Airport. The 3 way switch is composed of 3 moving girders, 4 fixed girders, driving units, moving units, clamping units and articulated angle relieving equipment etc. In this paper, the measured results on the interaction between vehicle and switch are discussed. The measured results are following; First, continuous moving test and natural frequency for girder and levitation rail. Second, levitation and lateral air gap of the bogies running on the curved switch. Third, noise of moving mechanical parts of the 3 way segmented switch. Forth, thermal displacement of the girder due to temperature change. With over the measured results, more reliability and stability of the 3 way segmented switch are secured.

  • PDF

Experimental Study on Wave-Induced Hydraulic Pressure subjected to Bottom of Floating Structures (부유구조체 하면에 작용하는 파압에 대한 실험적 연구)

  • Jeong, Youn-Ju;You, Young-Jun;Lee, Du-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.6A
    • /
    • pp.425-433
    • /
    • 2011
  • In this study, in order to investigate the wave-induced buoyancy effects, experimental studies were conducted on pontoon-type floating structures. A series of small-scale tests with various wave cases were performed on the pontoon models. A total of four small-scale pontoon models with different lateral shapes and bottom details were fabricated and tested under the five different wave cases. Six hydraulic pressure gauges were attached to the bottom surfaces of the pontoon models and the wave-induced hydraulic pressure was measured during the tests. Finally, hydraulic pressures subjected to the bottoms of the pontoon models were compared with each other. As the results of this study, it was found that whereas the waffled bottom shape hardly influenced the wave-induced hydraulic pressure, the hybrid lateral shape significantly influenced the wave-induced hydraulic pressure subjected on the bottoms of floating structures. The air gap effects of the hybrid shape contribute to decreasing the wave-induced hydraulic pressure due to absorption of wave impact energy. Compared with box type, the hydraulic pressures of the hybrid type were about 83% at the bow, 74% at the middle, and 53% at the stern.

Shape Optimization of a Switched Reluctance Motor Having 6/4 Pole Structure for the Reduction of Torque Ripple Using Response Surface Methodology (반응표면법을 이용한 6/4극 구조를 갖는 스위치드 릴럭턴스 모터의 토크 리플 저감을 위한 형상 최적설계)

  • Choi, Yong-Kwon;Yoon, Hee-Sung;Koh, Chang-Seop
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.608-616
    • /
    • 2006
  • Recently, a switched reluctance motor is widely used in various industries because it has many advantages such as a simple structure, robustness, less maintenance, high torque/weight ratio, and easy speed control over other types of motors. However, a switched reluctance motor inherently produces acoustic noise and vibration caused by torque ripple. Applications of these motors where silent operation is desirable have thus been limited. In this paper, a new stator pole face having a non-uniform air-gap and a pole shoe attached to the lateral face of the rotor pole are suggested in order to minimize torque ripple. The effects of each design parameter are validated using a time-stepping finite element method. The parameters are optimized by utilizing response surface method (RSM) combined with (1+1) evolution strategy. The result shows that the optimized shape gives higher average torque and drastically reduced torque ripple.

Analysis and Design of a Magnetic Levitation Rail using the Repulsive Force of Permanent Magnets (영구자석의 반발력을 이용한 자기부상레일의 해석 및 설계)

  • 이강원;송창섭
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.48-54
    • /
    • 1999
  • For the high speed linear motor and the transportation device at clean room, a magnetic levitation rail without contact using the repulsive force of permanent magnets was newly developed. The characteristics of repulsive and lateral forces of the magnetic levitating system using permanent magnet was studied and the devised magnetic levitating system was evaluated by analytical and experimental approaches. This system is composed of two fixed guide rails with the rare earth permanent magnet array and a moving unit which is attached two magnet pairs at each sides. Because this system was forcedly levitated by the face to face repulsive forces, levitating air gap length can be repulsive force of an auxiliary magnetic repulsion system on the center of moving unit.

  • PDF

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.