• Title/Summary/Keyword: Latent Heat

Search Result 641, Processing Time 0.028 seconds

Assessment of actual evapotranspiration using modified satellite-based priestley-taylor algorithm using MODIS products (MODIS 위성자료를 이용한 Modified Satellite-Based Priestley-Taylor (MS-PT)의 적용 및 실제 증발산 평가)

  • Baik, Jongjin;Park, Jongmin;Choi, Minha
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.11
    • /
    • pp.903-912
    • /
    • 2016
  • Accurate understanding and estimating Evapotranspiration (ET) is essential for understanding the mechanism of water cycle and water budget. ET has been analyzed by many researchers in worldwide while Ground-based ET has limiation in analyzing the spatio-temporal pattrens of ET. Thus, many researches have been conducted to represent the spatio-temporal variation of ET by using hydrometeorological variables estimated from remote sensing datasets. Previous remote sensing based ET algorithms, however, have disadvantage in that various hydrometeological input datasets were required. In this study, actual ET was estimated by MODIS-based Rn and MS-PT algorithm requiring relatively less input data than previous method. The result confirmed that the observed $R_N$ and latent heat flux from the eddy-covariance based fluxtowers located at CFK and SMK showed high correlation with the estimated $R_N$ and ET. The average determination coefficients ($R^2$) of ET estimated from satellite dataset over study periods were 0.77 (0.72-0.81) in Cheongmi (CFK) and 0.70 (0.67-0.78) in Sulma (SMK), respectively. Comparing with the actual ET of two flux tower sites, however, SMK showed more overestimated patterns than CFK due to the vegetation and radiation related errors.

1-D Analysis for Water Spray Cooling of Exhaust Gas in Combustor Test Facility (물 분무를 이용한 연소가스 냉각 1차원 해석)

  • Im, Ju Hyun;Kim, Myung Ho;Kim, Yeong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.1
    • /
    • pp.61-67
    • /
    • 2015
  • The cooling of hot exhaust gas is an important issue for the construction of combustor test facility. Water spray is an effective method for exhaust gas cooling due to its large latent heat in process of evaporation. In this study, 1-D analysis has been performed based on continuity, energy conservation, and saturated vapor property to understand water spray cooling of combustion gas. In the exhaust duct of combustor test facility, the injected water decreases combustion gas temperature, and evaporates in the combustion gas. However, some of the injected water is collected in the sump due to condensation. The evaporation of water helps combustion gas cooling, but causes pressure increase inside the exhaust duct due to increase of vapor pressure. These phenomena has been analyzed by 1-D modeling in this study. From 1-D analysis, the adequate mass flow rate of water spray to cool combustion gas and to avoid excessive pressure rise inside the exhaust duct has been decided.

Adequacy evaluation of the GLDAS and GLEAM evapotranspiration by eddy covariance method (에디공분산 방법에 의한 GLDAS와 GLEAM 증발산량의 적정성 평가)

  • Lee, Yeongil;Im, Baeseok;Kim, Kiyoung;Rhee, Kyounghoon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.10
    • /
    • pp.889-902
    • /
    • 2020
  • This study was performed in Seolmacheon basin to evaluate the adequacy of GLDAS (Global Land Data Assimilation System) and GLEAM (Global Land Evaporation Amsterdam Model) evapotranspiration data. The verification data necessary for the evaluation of adequacy were calculated after processing the latent heat flux data produced in the Seolmacheon basin with the Koflux program. In order to gap-fill the empty period, alternative evapotranspiration was calculated in three ways: FAO-PM (Food and Agriculture Organization-Penman Monteith), MDV (Mean Diurnal Variation) and Kalman Filter. This study selected Kalman Filter method as the data gap-filling method because it showed the best Bias and RMSE among the three methods. The amount of GLDAS spatial evapotranspiration was calculated as Noah (version 2.1) with a time interval of 3 hours and a spatial resolution of 0.25°. The amount of GLEAM spatial evapotranspiration was calculated using GLEAM (version 3.1a). This study evaluated the spatial evapotranspiration of GLDAS and GLEAM as the evapotranspiration based on eddy covariance. As a result of evaluation, GLDAS spatial evapotranspiration showed better results than GLEAM. Accordingly, in this study, the GLDAS method was proposed as a method for calculating the amount of spatial evapotranspiration in the Seolmacheon basin.

Classification and Characterization of Bacteriophages of Lectobacillus casei (Lactobacillus casei Bacperiophage의 분류 및 특성에 관한 연구)

  • 김영창;박민철;강국희;윤영호;이광웅
    • Korean Journal of Microbiology
    • /
    • v.17 no.4
    • /
    • pp.165-178
    • /
    • 1979
  • Phages of Lactobaciilus casei (PLC) isolated from plant drainage were classified and characterized. The results are as follows : 1. On the basis of host range pattern, phages could be divided into 2 groups (PLC-B and PLC-C). PLC-B group phages could be further divided into 5 sub-groups $(B_1, \;B_2, \;B_3, \;B_4, \;and\;B_5)$. Although PLC-C group phages had the same host range, they could be also divided into 2 sub-groups $(C_1\;and\;C_2)$ by morphlogical type. 2. It was $B_3$ group phages that represented a major proportion (44.4%) of phages tested. However, $B_1$ group phages were shown to have the widest host range. 3. Electron micrographs revealed that the phages fell into three different morphological types. $(B_1, \;B_2, \;and\;B_3)$ group phages hd a hexagonal head (52nm in diameter) and a sheathless noncontractile (245 nm in length). $B_4\;and\;C_2$ group phages had a hexagonal head (56 nm) and a short flexible tail (169nm) having no sheath. $B_5\;and\;C_1$ group phages were shown to have a hexagonal head (81 nm) and a contractile tail (140 nm) having a sheath, a base plate and tail fibers. 4. The inactivation of the phages by antisera indicated that serological relationships correlated completely with morphological types. 5. $B_1, \;C_1\;and\;C_2$ group phages produced a large (1, 2 mm in diameter) plaque with a clear ring. The morphology of plaques of $B_3\;and\;B_5$ group phages was the same as those produced by the above, but the average plaque sizes for $B_3\;and\;B_5$ were 0.8 mm abd 0.5 mm, respectively. $B_2\;and\;B_4$ group phages produced a small (0.5 mm) turbid plaque with an irregular edge. 6. The latent period and the average burst size of $B_1\;and\;B_3$ group phages were 90 min and 100, respectively. These phages reuqired calcium ions for their miltiplication. 7. $B_3$ group phages could not be absrobed to R-variant $KC_1$. 8. The order of resistance of phages to heat was $B_2\;>\;B_1, B_4\;and\;B_5\;>\;B_3\;and\;C_2, \;B_5$ group phages were more stable than $B_3$ in various pH values. $C_2$ group phages were more sensitive to UV irradiation than $B_1\;and\;B_3$ group phages. 9. Strains YIT9018 and IAM 1043 were induced by mitomycin C treatment. Phage particles detected in the lysates had a hexagonal head (38 and 49 nm, respectively), but no tail. Any sensitive indicator strain could not be isolated in spite of repaeated trials.

  • PDF

Changes in the Skin Temperature and Electrical Skin Resistance Following Ingestion of Red Pepper (고온환경에서의 한국인 작업능력 - 고추가 피부의 온도 및 전기저항에 미치는 영향 -)

  • Shin, Dong-Hoon;Cho, Jang-Ze;Chang, Se-Koo;Koh, Jae-Pyong;Earm, Yung-E
    • The Korean Journal of Physiology
    • /
    • v.4 no.1
    • /
    • pp.19-28
    • /
    • 1970
  • In order to investigate the changes in the temperature regulation mechanism following ingestion of red pepper, twenty healthy man were given 2 gms of powdered red pepper each in 100 ml of water at room temperature, $20^{\circ}C$, Simultaneous recordings of temperature and electrical resistance of the skin of forehead were taken by means of Physiograph, using appropriate transducers. Temperature of various spots such as the cheek, upper tack and the forearm was also measured by the telethermometer at interval of two minutes. The results obtained were as follows: 1. Seventeen out of 20 subjects showed immediate rise in the skin temperature of the forehead, and 11 of them manifested the oscillating pattern of the skin temperature. The average of the largest peak amplitude was $0.58{\pm}0.355^{\circ}C$. 2. Even those who failed to show the immediate rise in the temperature did not keep the quiescence over 9 minutes, and delayed responses were revealed. 3. The rise in tile skin temperature is the favourable sign for the heat discipating mechanism only because the sweat glands are activated with the concomittant rise in the temperature of the skin. 4. There was a preceding or coincide fall in the electrical resistance of the skin, and it was also attributed to the glandular activity. 5. At rather cool room temperature, $20^{\circ}C$, no visible sweat was seen during the period of observation. Nevertheless it was obvious that latent activation of the sweat glands was triggered and the. threshold was lowered. This situation imitates the acclimatized condition in the hot environment, and it is likely to increase the tolerance in tropical climate from the view point of temperature regulation.

  • PDF

Study on Surface Temperature Change of PV Module Installed on Green Roof System and Non-green Roof System (옥상녹화와 비 옥상녹화 평지붕에 설치 된 PV모듈의 표면온도 변화 고찰)

  • Yoo, Dong-Chul;Lee, Eung-Jik;Lee, Doo-Ho
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.214-219
    • /
    • 2011
  • Today, various activities to save energy are being conducted around the world. Even in our country, carbon reduction policy is being conducted for low carbon green growth and with this movement, effort to replace energy sources by recognizing the problems on environment pollution and resource exhaustion due to the indiscrete usage of fossil fuel is being made. Therefore, active study on renewable energy is in progress as part of effort to replace the energy supply through fossil fuel and solar ray industry has rapidly developed receiving big strength of renewable energy policies. The conclusion of this study measuring the surface temperature change of single crystal and polycrystalline PV module in green roof system and non-green roof system aspect are as follows. There was approximately $4^{\circ}C$ difference in PV module temperature in green roof system and non-green roof system aspect and this has the characteristic to decrease 0.5% when the temperature rises by $1^{\circ}C$ when the front side of the module is $20^{\circ}C$ higher than the surrounding air temperature following the characteristic of solar cells. It can be concluded that PV efficiency will be come better when it is $4^{\circ}C$ lower. Also, in result of temperature measurement of the module back side, there was $5^{\circ}C$ difference of PV module installed on the PV module back side and green roof system side on the 5th, $3^{\circ}C$ on the 4th, $2^{\circ}C$ on the 5th to show decreasing temperature difference as the air temperature dropped, but is judged that there will be higher temperature difference due to the evapotranspiration latent heat effect of green roof system floor side as the temperature rises. Based on this data, it is intended to be used as basic reference to maximize efficiency by applying green roof system and PV system when building non-green roof system flat roof.

  • PDF

Typhoon Simulation with a Parameterized Sea Surface Cooling (모수화된 해면 냉각을 활용한 태풍 모의 실험)

  • Lee, Duho;Kwon, H. Joe;Won, Seong-Hee;Park, Seon Ki
    • Atmosphere
    • /
    • v.16 no.2
    • /
    • pp.97-110
    • /
    • 2006
  • This study investigates the response of a typhoon model to the change of the sea surface temperature (SST) throughout the model integration. The SST change is parameterized as a formulae of which the magnitude is given as a function of not only the intensity and the size but the moving speed of tropical cyclone. The formulae is constructed by referring to many previous observational and numerical studies on the SST cooling with the passage of tropical cyclones. Since the parameterized cooling formulae is based on the mathematical expression, the resemblance between the prescribed SST cooling and the observed one during the period of the numerical experiment is not complete nor satisfactory. The agreements between the prescribed and the observed SST even over the swath of the typhoon passage differ from case to case. Numerical experiments are undertaken with and without prescribing the SST cooling. The results with the SST cooling do not show clear evidence in improving the track prediction compared to those of the without-experiments. SST cooling in the model shows its swath along the incomplete simulated track so that the magnitude and the distribution of the sea surface cooling does not resemble completely with the observed one. However, we have observed a little improvement in the intensity prediction in terms of the central pressure of the tropical cyclone in some cases. In case where the model without the SST treatment is not able to yield a correct prediction of the filling of the tropical cyclone especially in the decaying stage, the pulling effect given by the SST cooling alleviates the over-deepening of the model so that the central pressure approaches toward the observed value. However, the opposite case when the SST treatment makes the prediction worse may also be possible. In general when the sea surface temperature is reduced, the amount of the sensible and the latent heat from the ocean surface become also reduced, which results in the weakening of the storms comparing to the constant SST case. It turns out to be the case also in our experiments. The weakening is realized in the central pressure, maximum wind, horizontal temperature gradient, etc.

The study on ShanghanLun PingMaiFa (1) (『상한론(傷寒論)·평맥법(平脈法)』에 관한 연구(1))

  • Choi, Jin-Young;Park, Kwang-Cheon;Jeong, Han-Sol;Ha, Ki-Tae;Shin, Sang-Woo
    • The Journal of Korean Medical History
    • /
    • v.25 no.2
    • /
    • pp.63-96
    • /
    • 2012
  • The PingMaiFa chapter, which is the second chapter of SongBon ShangHanLun, is the scholarly description(專論) of the pulse and pathological mechanism but has not been studied and published yet. This study is about article 1-13 which is the first part of The PingMaiFa chapter. We compared the original texts within the editions, comparing and analyzing the annotations of successive dynastic medical group. The articles of The SongBon ShangHanLun PingMaiFa chapter 1-13 is consisted as is shown: article 1 states about the general features of normal pulse (平脈) and its physiological mechanism and the morbid pulses (病脈) caused by wind, cold, retained fluid, pain and heat vexation, article 1,10 state about the normal pulses of Five viscera (lung, heart, spleen, liver and kidney) and their manipulations in pulse taking, article 2 states about the differentiations of deficiency and excess syndrome according to pulse conditions, article 3, 4 state about the estimation of good prognoses and a factitious disorder by the combination of pulses and symptoms, article 6 states about Latent qi (伏氣) and its diagnostic features, article 5 states about inspection and listening examination as co-diagnostic methods of the pulse diagnosis, article 7, 8, 9 state that the emotions, such as fear and shame, and the dietary are important factors to consider for making diagnosis, article 11 states about the overwhelming pulse (相乘脈) which indicates the abnormal correlations between five phases and appears in four patterns as the dissolute(縱), the unrighteous(橫), the unfavorable(逆) and the favorable(順), article 12 states about 6 harmful pulses(殘賊脈), which are string-like pulse(弦脈), tight pulse(緊脈), floating pulse(浮脈), slippery pulse(滑脈), sunken pulse(沈脈), rough pulse(澁脈), article 13 states about "JaeGoe"(災怪) which is an unexpected response after treatment and it comes because of the formulas that had before. Throughout all these articles, The PingMaiFa chapter not only offers great value for Pulse-taking diagnosis, but also leads to a better understanding of clinical applications.

A Study on the Measurement of Knowledge Relatedness Density and Technological Complexity in South-east Region (동남권 지역의 지식 간 연관성 밀도와 기술 복합성 측정에 관한 연구)

  • Park, Gi-Woong;Kim, Donghyun
    • Journal of the Korean Regional Science Association
    • /
    • v.37 no.3
    • /
    • pp.3-18
    • /
    • 2021
  • The fourth Industrial Revolution is transforming the industrial structure of the region, and it is necessary to develop new industries and technologies that reflect regional characteristics. The purpose of this study is to measure the knowledge relatedness and technological complexity in Busan, Ulsan, and Gyeongnam, and to identify technologies with potential for regional industrial differentiation strategies. Using patent data from 2015 to 2019, co-occurrence matrices were derived from 652 IPC codes, and the knowledge relatedness density and technology complexity index were calculated. Network analysis was performed using the knowledge relatedness density. As a result of analysis, it was found that mechanical engineering occupied a large proportion, followed by chemistry and electrical engineering. As a result of applying the risk-benefit framework to derive technologies with the potential to differentiate local industries, the technological capabilities of low-risk-high-benefit were different. Among mechanical engineering, technologies such as engine, machine operation, and transportation were included in Busan. In Ulsan, environmental technology in chemical and materials, and heat treatment technology in mechanical engineering were technologies with low-risk and high-benefit capabilities. Gyeongnam showed competence in mechanical engineering, chemistry, and electrical engineering in some areas such as Gimhae, Yangsan, and Changwon. The results of this study are meaningful in that they identified technologies with potential for selecting and deriving strategic industries for regional growth based on latent knowledge in the region.

Evaluation of thermal stress of poultry according to stocking densities using mumerical BES model (BES 수치모델을 이용한 사육 밀도별 가금류 고온 스트레스 평가)

  • Kwon, Kyeong-seok;Ha, Tahwan;Choi, Hee-chul;Kim, Jong-bok;Lee, Jun-yeob;Jeon, Jung-hwan;Yang, Ka-young;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sang-yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.456-463
    • /
    • 2019
  • Micro climatic conditions within the livestock facility are affected by various factors such as ventilation, cooling, heating, insulation and latent and sensible heat generation from animals. In this study, numerical BES method was used to simulate energy flow inside the poultry house. Based on the BES method and THI concept, degree of thermal stress of poultry was evaluated according to the locations in South Korea. Comparison of THI values within the poultry house was also carried out according to the stocking densities to reflect recent animal-welfare issue. Significant decrease in thermal stress of poultry was observed when the stocking density of $30kg/m^2$ was applied in the change of the seasons(p<0.05) however, there was no statistically significant difference in summer season(p>0.05). It meant that installation of proper cooling system is urgently needed. For Iksan city of Jeollabuk-do province, total 252 hours of profit for thermal stress was found according to decrease in the stocking density.