• Title/Summary/Keyword: Laser-Interferometer

Search Result 366, Processing Time 0.024 seconds

Error Assessment of CMM by Self-calibration Method (자가 보정 방법을 이용한 삼차원 측정기의 계통 오차 추출)

  • 유승봉;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.379-382
    • /
    • 2002
  • Among the CMM calibration techniques, the calibration with standard specimen is most accurate way to acquire the required precision. When there is no standard specimen, the calibration of CMM with itself is possible. This calibration method is called "self-calibration". In this paper, we developed self-calibration algorithm for CMM XY plane. It is possible to calculate the in-plane error and out-of-plane error of CMM with 3 different measurement of same artifact. Experimental result shows that the non-orthogonality error is dominant in in-plane error and the self-calibration result and laser interferometer measured result have almost same value.ame value.

  • PDF

Precision Phase Calibration System of Accelerometers (가속도계 정밀 위상 교정 시스템)

  • Lee, Yang-Bong;Jung, Sung-Soo;Jin, Jong-Han
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.5
    • /
    • pp.585-590
    • /
    • 2011
  • Accelerometers have been exploited widely in various fields from monitoring vibration of precision machines to detecting an earthquake wave. The precision calibration of the accelerometers is required to maintain the measurement reliability when measuring the vibration of objects with accelerometers for modal analysis. Among evaluation factors for determining sensitivity of accelerometers, phase delay term should be also considered for accurate calibration. In this paper, a new calibration system of accelerometers capable of measuring phase delay as well as magnitude of its sensitivity was proposed and realized in the frequency range of 20 Hz to 5 kHz.

A possible application of the nonuniform electric field measurement using Pockets effect (포켈스 효과를 이용한 불평등 전계 측정)

  • Kang, W.J.;Lim, Y.S.;Choi, J.O.;Chang, Y.M.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.513-515
    • /
    • 2000
  • In this paper, new Partial Discharge (PD) detection technique using Pockels-cell was proposed. For this purpose, PD was generated from needle-plane electrode in air and detected by optical measuring system using Pockets cell, based on Mach-Zehnder interferometer, consisting of He-Ne laser, single mode optical fiber, 50/50 beam splitter and photo detector. We show the characteristic of the proto-type sensor for the corona discharge.

  • PDF

Mode Analysis and Modal Delay Measurement of a Few-Mode Fiber by Using Optical Frequency Domain Reflectometry

  • Ahn Tae-Jung;Moon Sucbei;Youk Youngchun;Jung Yongmin;Oh Kyunghwan;Kim Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.54-58
    • /
    • 2005
  • A novel mode analysis method and differential mode delay measurement technique for a multimode optical fiber based on optical frequency domain reflectometry has been proposed for the first time. We have used a conventional OFDR with a tunable external cavity laser and a Michelson interferometer. A few-mode optical multimode fiber was prepared to test our proposed measurement technique. The differential mode delay (DMD) of the sample fiber was measured to be 16.58 ps/m with a resolution of 1.5 ps/m. We have also compared the OFDR measurement results with those obtained using a traditional time-domain measurement method.

Development of ultra precision rotational stage using Semi-inchworm driving mechanism with PZT (PZT를 이용한 Semi-inchworm구동기법의 초정밀 회전 스테이지 개발)

  • Yun, Deok-Won;Ahn, Kang-Ho;Han, Chang-Soo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.6 no.1 s.18
    • /
    • pp.37-41
    • /
    • 2007
  • Recently PZT is used in ultra precision mechanism field. PZT has a small motion range although it has a high resolution. Many methods, such as inchworm, impact driving, etc., have been applied for the expansion of the motion range.? In this study, the new actuating mechanism for rotational motion with two PZT actuators is proposed. The ultra precision rotational actuator which is made by proposed mechanism is able to operate both coarse and fine motion. The design parameters of the proposed mechanism are considered to improve the performance of the system. The rotational stage which is applied by the proposed mechanism is fabricated. The resolution and velocity for fabricated rotational stage are measured by laser interferometer.

  • PDF

Review on Reliability Test Method for Optical/Thermofluidic Micro Component (광열유체 마이크로 부품의 신뢰성 평가를 위한 시험법에 관한 고찰)

  • 이낙규;나경환;최현석;한창수
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.242-247
    • /
    • 2004
  • Literature review on reliability test method for developing high performance optical/thermofluidic components. Since the miniaturization by the conventional mechanical process is limited to milli-structure, i.e. $10^{-3}m$, new technology for fabricating of mechanical components is needed to match cost, reliability, and integrability criteria of micro-structure. Although numbers of various researches on MEMS/MOEMS devices and components, including material characterization, design and optimization, system validation, etc., the lack of standards and specifications make the researches and developments difficult. For that reason, this paper is intended to propose the methods of reliability test for measuring the mechanical property of optical/ thermofluidic components.

A Driving and Pick-Off Method of Vibratory Gyroscopes Using Electromagnetic Force (전자기력을 이용한 진동형 자이로스코프의 가진 및 검출 기법 연구)

  • 이정영;홍성경
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 2003
  • Driving and pick-off using electromagnetic force for a cylindrical vibratory gyroscope is considered. A gyroscope consisting of thin cylindrical vibrating element and electromagnetic drive and pick-off element is designed, fabricated and tested. The results of the proposed pick-off method were compared with the results of the highly precise laser interferometer and eddy current sensor as it was used as the reference standard. Through the experiment, it is verified that the proposed electromagnetic driving and pick-off method can be an effective alternative to conventional electrostatic or piezo-electric methods.

A Study of Optical Follow-up Pipeline for Gravitational-Wave transients using QUEST data

  • Kim, Yong Bum;Lee, Hyung Mok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.69.2-69.2
    • /
    • 2013
  • The direct detection of gravitational wave has a very important meaning as a basis for verification of the theory of relativity. Several laser interferometer detectors have attempted to detect GW directly (e.g. LIGO, VIRGO), but positional accuracy of GW detector is too wide (about 10~100sq deg) to find which objects emit GW. One of the main sources of GW is gamma-ray burst which can be detected even in electromagnetic wave. Then to verify Gamma-ray burst object as a GW source, we proceed EM follow-up observation with wide field of view. A first program initiating EM follow-ups to possible transients GW events has been developed and exercised by LIGO and VIRGO community in association with several partners. Using QUEST optical data, we tested the method of cross-convolution recommended by EM follow-up community. We will describe the results of that test.

  • PDF

Synthesis of the Measurement System on the Machine Tool (공작기계 상에서의 측정시스템의 설계)

  • Chung, Sung-Chong;Kim, Kyung-Don
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.63-68
    • /
    • 1999
  • A 2$\frac{1}{2}$ dimensional measurement and inspection system realized on the machine tool using a touch trigger probe and measuring G codes is synthesized in this paper. Measuring G codes have been constructed according to geometric farms, precision attributes, relationships between two parts, datum hierarchies, and relevant technological data by using measuring arguments. Algorithms far calibration and compensation of measuring errors are proposed to ensure the measuring accuracy by using a laser interferometer and ring gauges. Classification of feed rates according to the objectives of movement makes it possible to reduce measuring time and also implement collision-free measurement. Experiments are conducted to verify the validity and effectiveness of proposed methods.

  • PDF

Mechanical Prperty Change of Compositionally Modulated Amorphous $Fe_{80}Zr_{20}$ Thin Film by Electrolytic Hydrogenation (조성 변조된 비정질 $Fe_{80}Zr_{20}$ 박막의 전해적 수소 취입에 의한 기계적 성질의 변화)

  • Lee, Byeong-Hak
    • Korean Journal of Materials Research
    • /
    • v.6 no.6
    • /
    • pp.632-635
    • /
    • 1996
  • 조성 변조된 비정질 Fe80Zr20박막의 자기적 성질과 기계적 성질 변화를 전해적 방법에 의한 수소 취입 시간의 함수로 측정하여, 그 상관 관계를 연구하였다. 박막의 Young's modulus는 진동 cantilever 시료의 공명 주파수를 , 10-4nm의 측정 감도를 지닌 laser heterodyne interferometer를 써서 측정하였다. 농도 2N의 인산 전해액에 침적된 시료에 26.3mA/$\textrm{cm}^2$의 전류를 흘려 이루어진 수소취입에 의해, Fe80Zr20 박막의 포화자화 정도는 8배, Young's modulus는 18배 가량 증가하였다. Fe80Zr20박막의 자기적 성질의 변화가 원자적 scale의 미세 구조 변화에 의한 것이라는 간접적인 증거를 제공하였으며, cantilever 시료의 공명주파수 측정을 통하여 박막재료의 기계적 성질을 연구할 수 있는 새로운 가능성을 제시하였다.

  • PDF