• 제목/요약/키워드: Laser-Induced Fluorescent

검색결과 27건 처리시간 0.026초

마이크로 스케일 유동에서의 속도장 온도장 동시 측정 기법과 동전기 유동에의 적용 (Simultaneous Measurement of Velocity and Temperature Fields in Micro-Scale Flow and Its Application to Electrokinetic Flow)

  • 이범준;진송완;김영원;유정열
    • 대한기계학회논문집B
    • /
    • 제31권7호
    • /
    • pp.644-652
    • /
    • 2007
  • In this paper, a technique of simultaneously measuring the velocity and the temperature in micro-scale flow is proposed. This method uses particle tracking velocimetry (PTV) for measuring the velocity and laser induced fluorescence (LIE) for measuring the temperature. To measure the accurate velocity and temperature, images for PTV and for LIE are separated by using two light sources and a shutter which is synchronized with a camera. By using only one camera, measurement system can be simplified and the error from complicate optical system can be minimized. Error analyses regarding the concentrations of fluorescent dye and particle and the light source fluctuation are also conducted. It is found that the error of the temperature and the velocity highly depends on the concentration of fluorescent particles which are used for PTV. This technique is applied to the simultaneous measurement of the velocity and the temperature in the electrokinetic flow. It is found that the velocity and temperature vary with the electric field strength and the concentration of electrolyte.

마이크로 레이저 형광 여기법을 이용한 미세채널 내부에서의 산소 확산에 대한 정량적 가시화 (Quantitative Visualization of Oxygen Transfer in Micro-channel using Micro-LIF Technique)

  • 천쥐안;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제10권1호
    • /
    • pp.34-39
    • /
    • 2012
  • In the present study, oxygen transfer process across gas-liquid interface in a Y-shape micro-channel is quantitatively visualized using the micro laser induced fluorescence (${\mu}$-LIF) technique. Diffusion coefficient of Oxygen ($D_L$) is estimated based on the experimental results and compared to its theoretical value. Tris ruthenium (II) chloride hexahydrate was used as the oxygen quenchable fluorescent dye. A light-emitting diode (LED) with wavelength of 450 nm was used as the light source and phosphorescence images of fluorescent dye were captured by a CMOS high speed camera installed on the microscope system. Water having dissolved oxygen (DO) value of 0% and pure oxygen gas were injected into the Y-shaped microchannel by using a double loading syringe pump. In-situ pixel-by-pixel calibration was carried out to obtain Stern-Volmer plots over whole flow field. Instantaneous DO concentration fields were successfully mapped according to Stern-Volmer plots and DL was calculated as $2.0675{\times}10^{-9}\;m^2/s$.

LIF 및 CLSM을 결합한 미소 간극 내 유체의 단면 온도 분포 측정 기법 (Measurement of Cross-sectional Temperature Distribution in Micro-scale Gap Fluid Using LIF Technique in Combination with CLSM)

  • 정동운;이상용
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.834-841
    • /
    • 2006
  • In the present wort the Laser-induced Fluorescence (LIF) technique and Confocal Laser Scanning Microscopy (CLSM) have been combined to measure the temperature distribution across a micro-scale liquid layer as a direct and non-invasive method. Only the fluorescent light emitted from a very thin volume around a focal plane can be selectively detected, and it enables us to measure the liquid temperatures even at the close vicinity of the walls. As an experimental verification, a test section consists of two flat plates (for heating and cooling, respectively) separated by about 240 microns was made, and the methanol mixed with a temperature-sensitive dye, Rhodamine B, was filled in the gap between them. The measured temperature distribution across the gap showed good linearity, which is a typical characteristic of conduction heat transfer through a thin liquid layer. In result, the CLSM-LIF technique proposed in the present study was found to be a promising method to measure the local temperatures in the liquid flow field in microfluidic devices.

LIEE와 Mie 산란 방법을 이용한 직분식 가솔린 엔진의 스월 및 슬릿 인젝터의 분무 특성 (The Spray Characteristics of Swirl and Slit Injector to DISI Engine Using LIEF and Mie-scattering Method)

  • 이기형;황규민;이창희
    • 대한기계학회논문집B
    • /
    • 제29권3호
    • /
    • pp.356-367
    • /
    • 2005
  • The spray characteristics of DISI injector have a great role in gasoline engine efficiency and emission. Thus, many researchers have studied to investigate the spray characteristics of swirl and slit injectors that are used in a DISI engine. In this study, we tried to provide spray parameters, which affect on the spray characteristics such as injection pressure, ambient pressure and ambient temperature. In addition, we calculated $t_{b}\;and\;t_{c}$ to investigate the break up mechanism of test injectors and obtained $C_{v}$ to evaluate the spray characteristics. As the ambient pressure increases in case of slit injector, $C_{v}$ decreases. The laser-induced exciplex fluorescence (LIEF) technique, which is based on spectrally resolved two-color fluorescent emissions, has applied to measure the liquid and vapor phases for on evaporating spray simultaneously. The TMPD/naphthalene proposed by Melton is used as a dophant to detect exciplex signal. The temporal and spatial distribution of liquid and vapor phases during the mixture formation process was measured by this technique. In the LIEF technique, the vapor phase is detected by the monomer fluorescence while the liquid phase is tracked by the exciplex fluorescence. From this experiment, we found that the spray area of the vapor phase is increased with elapsed time after injection and the area of liquid is decreased when the ambient pressure is 0.1MPa. However, the area tends to increase until the end of injection when the ambient pressure is 1.0MPa.

PIV/LIF를 이용한 Basket Mill 내부의 유동특성에 관한 실험적 연구 (An Experimental Study on the Mixing Characteristics in a Basket Mill Using PIV/LIF Method)

  • 김현동;윤상열;정은호;류승규;김경천;김중일;유달현;양시영
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.56-59
    • /
    • 2004
  • An experimental study has performed to identify the mixing characteristics of basket mill by using PIV and LIF techniques. The velocity fields were measured at three sectors for each two types of basket mill model and various impeller speed. To verify the results of velocity field measurement and the concentration field, LIF measurement also was performed for three cases. There was an inactive region and a descending flow to the bottom of basket mill at the original model. But when the impeller type and the guide shape were changed, internal flow structure was improved suitably for mixing and dispersion. The improvement result in increment of inflow flow rate at the basket entrance about $10\%$.

  • PDF

레이저 유도 형광을 이용한 플라즈마 쉬스 내의 전기장의 측정

  • 김혁;송재현;정재철;황기웅
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.258-258
    • /
    • 2010
  • 레이저 유기 형광법은 비침투적인 방법으로 플라즈마를 진단할 수 있는 장점이 있다. 특히 헬륨 플라즈마 내에서 전기장이 존재하는 경우에 헬륨의 에너지 준위가 분리되는 STARK 효과를 이용하여 기판 부근에 발생한 쉬스 내의 전기장을 측정할 수 있다[1]. 그러나 플라즈마의 생성을 위한 RF 소스와 레이저 간의 위상이 동기화 되지 않는 경우엔, 그 결과 값의 보정이 필요하다. 외부의 전기장이 시변하는 경우에 각각의 위상에서 헬륨의 여기종이 느끼는 전기장의 세기는 다르다. 따라서 레이저가 어떤 타이밍에 입사되는 가에 따라 신호의 분리되는 정도가 달라지는데, 레이저와 외부 전기장의 위상을 동기화하지 않은 경우에는 관측된 신호는 각각의 위상에서 여러 가지로 분리된 신호가 더해진 합의 형태로 나타난다. 이는 외부에서 인가된 전기장의 가장 큰 값을 나타낸다고 알려져 있었다[2]. 그러나 레이저 유도 형광 신호는 넓게 분산을 가지므로 이는 보정되어야 한다. 본 연구에서는 각각의 위상에서 출력되는 형광 신호를 구하고 시간의 영역에서 1주기 동안 적분하여 실제로 관측될 레이저 유도 형광신호의 보정치를 계산하였다. 이를 실험적으로 검증하기 위해서 유도 결합 플라즈마 반응 챔버 내에서 플라즈마를 방전시킨 후에, 레이저 유도 형광법을 사용하여 기판 위에 생성된 쉬스 내의 전기장을 측정하였다. 그리고, 랑뮤어 프루브를 이용하여 벌크 플라즈마 내의 플라즈마 전압을 구하고, 이를 적분 상수로 삼아 쉬스 내의 전위 분포를 구하였다. 또한 기판에 인가되는 전압을 직접 측정하여 위에서 구한 전위 분포치와 보정을 한 후의 전위 분포치를 비교, 검토하여 보정치를 검증하였다.

  • PDF

Experimental Investigation of Horizontal Buoyant Discharges from a Rosette-type Riser Using LIF System

  • Kwon, Seok Jae;Seo, Il Won;Kim, Ho Jung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2004년도 학술발표회
    • /
    • pp.463-467
    • /
    • 2004
  • Rosette-type diffusers with four-ports per riser are constructed in relatively shallow water in Korea. However, the trajectorial bending phenomena due to lower-pressure inside the surrounded buoyant jets on the riser was not considered in most models and was not observed without any experimental results. The buoyant jet behavior affected by the bending effect where there have been growing interests need to be verified experimentally and need to be preceded in the analysis of the characteristics of the buoyant jets oil a riser. The hydraulic model experiments have been carried out to investigate the characteristics of the behavior of horizontal buoyant jets discharged from a Rosette-type riser with four ports as well as single port over a certain range of the experimental conditions including initial momentum and initial buoyancy using LIF (Laser Induced Fluorescence) system to obtain concentration fields. The intensity of the fluorescent light in each pixel on the images obtained from LIF system with the tracer of Rhodamine H was converted to the local dye concentration with a set of calibration procedures to account for the non-uniform distribution of light intensity and the attenuation of light energy by water medium. The experimental results shows that the trajectories from Your ports tend to bend more and more to the inner side with the increase of the densimetric Froude number while the buoyant jet from a single port rises up without any bending phenomena. The previous models, VISJET and Seo et al. (2002), do not simulate the trajectories well except the region before the bending section. This study will focus on the analysis of the behavior of the buoyant jets for mainly a Rosette-type riser by conducting hydraulic model experiments using LIF system.

  • PDF