• Title/Summary/Keyword: Laser treatment

Search Result 1,150, Processing Time 0.032 seconds

Comparison of Characteristics on Induction and Continuous Nd:YAG Laser Surface hardening of SM45C Steel (SM45C강의 연속파 Nd:YAG레이저표면경화와 고주파표면경화특성 비교)

  • Shin H.J.;Yoo Y.T.;Ahn D.G.;Shin B.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.176-183
    • /
    • 2005
  • Laser heat treatment technology is used for improving the feature of fatigue resistance and wear resistance in mobile parts. The purpose of this study is to compare the characteristics of laser heat treatment and high frequency heat treatment, which is commonly used in industrial place. For the preemptive experiment, the distribution, depth and size of hardening and its micro-structural features were compared between surface heat treatment case by defocusing and variables of each process for heat treatment by exclusively manufactured heat treatment optical system. As a result, high frequency heat treatment has wide distribution of hardening depth and width about 3 times larger than laser heat treatment, however, its average hardness showed 621.4Hv which is smaller than the average hardness of laser heat treatment with 691Hv.

  • PDF

Stability and Effectiveness of Laser and Liquiband Treatments in the Rat Model of Oral Ulcer

  • Kang, Ji Won;Ryu, Hyun Seok;Abueva, Celine;Chung, Phil-Sang;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.10 no.4
    • /
    • pp.207-213
    • /
    • 2021
  • Background and Objectives This study was undertaken to assess the stability and efficacy of laser therapy (808 nm), Liquiband (a commercial topical skin adhesive product), and a combination treatment, for application in oral ulcers. Materials and Methods The oral ulcer rat animal model was used to determine the efficacy of photobiomodulation, Liquiband, or combination therapy. Ulcers were induced by injecting 60% acetic acid in the oral mucosa. Three days after ulcer confirmation, the chemically induced ulcers were treated with either laser (808 nm), Liquiband, or a combination of both, every two days for 8 days (4 sessions). Combination therapy was performed by first treating with laser followed by application of the Liquiband. Reduction in ulcer area size was subsequently determined, and animals were sacrificed at 5 and 10 days after the last administration, for histological observation of the extracted oral ulcer tissue samples. Results In this study, treatment with either laser (808 nm) or commercial Liquiband product as well as the combined treatment significantly enhanced oral ulcer healing in the rat animal model. The effect of laser treatment is mainly attributed to collagen synthesis, whereas application of the Liquiband promotes vascularization and formation of granulation tissue. Our results indicate that further optimization of the combined therapy could synergistically and significantly enhance oral ulcer healing. Conclusion Laser or Liquiband treatment of oral ulcer in the rat animal model exert different outcomes, but both methods confirm significant effects relative to the untreated group. The combined treatment group with laser and Liquiband showed marked oral ulcer healing, but further optimization is required to get highly significant results and establish the potential synergistic effect of the combination therapy, as compared to the individual enhancing effects of healing oral ulcers.

Treatment of Laryngotracheal Papilloma with 532-nm Diode Laser

  • Shim, Jaehyun;Choi, Soo Jeong;Jung, Kwang-Yoon;Baek, Seung-Kuk
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.190-193
    • /
    • 2020
  • A 45-year-old Korean male with laryngotracheal papilloma was treated using a 532-nm diode laser at six watts with a pulse width of 25 milliseconds. Two months after the laser treatment, the resected region was well-healed without significant scar contracture. This outcome suggests that a 532-nm diode laser can be a safe and effective treatment for laryngotracheal papilloma.

Clinical applcation of water laser (Er,Cr:YSGG) (물방울 레이저의 다양한 임상 적용)

  • Park, Jung-Hyun
    • The Journal of the Korean dental association
    • /
    • v.56 no.7
    • /
    • pp.385-390
    • /
    • 2018
  • Laser means "Light amplification by stimulated emission of radiation". Laser have unique characteristics according to wavelength. Wavelenth of Waterlase is 2780nm and it can be absorbed to water and hydroxyapatite. When laser is applied to some material, its temperature goes up due to laser's energy. But in dental treatment high temperature is not good for teeth. High temperature can make dental pulp and bone necrosis. Waterlase can be absorbed to water droplet, so when it burst, it can cut soft and hard tissue without raising temperature. so it is so proper to dental treatment.

  • PDF

Treatment of an Atrophic Scar with Fractional Carbon Dioxide Laser-assisted Poly-L-lactic Acid Delivery

  • Kim, Wan Jin;Jung, Ha Rin;Lee, Sang Ju;Cho, Han Kyoung
    • Medical Lasers
    • /
    • v.10 no.3
    • /
    • pp.181-184
    • /
    • 2021
  • Scars can cause great psychological stress among patients. Currently, there are numerous topical agents, laser and surgical treatments available for skin rejuvenation and scar minimization. Laser-assisted drug delivery (LADD) is a treatment method that increases drug delivery by stimulating the skin physically and chemically to enhance the penetration of topical agents. This is one of the areas of great interest in the treatment of various skin diseases in addition to its use for cosmetic purposes. In particular, LADD is relatively non-invasive and has advantages in terms of accessibility and stability. Poly-L-lactic acid (PLLA) is a collagen stimulator known to gradually restore skin volume by inducing inflammation and fibroplasia. Herein, we report a case of treatment of an atrophic scar with fractional carbon dioxide laser-assisted PLLA delivery.

Characteristics Induction and Laser Surface hardening of SM45C Steel (SM45C강의 레이저표면경화와 고주파표면경화특성)

  • Na Gee-Dae;Shin Ho-Jun;Shin Byung-Heon;Yoo Young-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.39-50
    • /
    • 2006
  • Laser heat treatment technologies have been used to improve characteristics of wear and to enhance the fatigue resistance for automotive parts. The bjective of this research work is to investigate the influence of the process parameters, such as power of laser and defocused spot position, on the characteristics of laser heat treatment for the case of SM45C medium carbon steel. CW Nd:YAG laser is selected as the heat source. The optical lens with the elliptical profile is designed to obtain a wide heat treatment area with a uniform hardness. From the results of the experiments, it has been shown that the maximum hardness is approximatly 780 Hv when the power and the travel of laser are 1,095 W and 0.6 m/min, respectively. In addition, the hardening width using the elliptical lens was three time larger than that using the defocusing of laser beam.

The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive (레이저 처리후 임프란트 표면 변화에 관한 연구)

  • Kim, Tae-Jung;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.3
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

Reviewing Research on Laser Output Used for Treatment of Hair Loss (탈모 치료에 사용되는 레이저 출력에 관한 논문 연구)

  • Mok, Jung-Il;Lee, Ji-Eun;Seo, Hyung-Sik
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.27 no.2
    • /
    • pp.33-50
    • /
    • 2014
  • Objective : The purpose of this study is to analyze research trends on laser output used for treatment of hair loss. Methods : We searched papers using Pubmed, NDSL, KISS, and RISS. First search used the keyword "Laser, Alopecia" in Pubmed. Inclusion criteria were last 15 years, English, related to output. Finally we searched papers using the keyword "Laser and Alopecia" in NDSL, KISS, and RISS. Inclusion criteria were the same as first research except for English. Results : A total of 43 studies were found, 28 studies were excluded and 15 studies were selected and analyzed. And of the 15 studies, 7 studies were foreign papers and 8 studies were domestic papers on clinical application of laser status. Mainly Used type of laser was a diode laser. As a result, we found that treatment group had more improvement than control group. The range of the laser-output was 1mW-150W in Alopecia laser therapy. Conclusions : Low-level (LLLT) as well as High-level laser therapy (HLLT) can be effectively used as an alternative to the treatment of alopecia. Thus, further attention and studies are needed on this topic in order to reduce the side effects and demonstrate the effectiveness clearly.

Sensitivity Analysis of Processing Parameters for the Laser Surface Hardening Treatment by Using the Finite Element Method (유한요소법을 이용한 레이저 표면경화처리 공정변수의 민감도 해석)

  • 이세환;양영수
    • Journal of Welding and Joining
    • /
    • v.19 no.2
    • /
    • pp.228-234
    • /
    • 2001
  • A methodology is developed and used to evaluate the response sensitivity of the thermal systems to variations in their design parameters. Technique for computing the sensitivity of temperature distributions to changes in processing parameters needed to decide the more effective laser input parameters for laser surface hardening treatment is considered. In this study, a state equation governing the heat flow in laser surface treatment is analyzed using a three-dimensional finite element method and sensitivity data of the processing parameter obtained using a direct differentiation method is applied to the sensitivity analysis. The interesting processing parameters are taken as the laser scan velocity and laser beam radius ( $r_{ b}$), and the sensitivities of the temperature T versus v and $r_{b}$ are analyzed. These sensitivity results are obtained with another parameters fixed. To verify the numerical analysis results, hardened layer dimensions (width and depth) of the numerical analysis are compared with the experimental ones.nes.

  • PDF

Verruca Plana Successfully Treated with a 2790-nm Erbium: Yttrium-scandium-gallium-garnet Laser

  • Park, Su Jung;Park, Kui Young;Seo, Seong Jun;Hong, Ji Yeon
    • Medical Lasers
    • /
    • v.9 no.1
    • /
    • pp.76-78
    • /
    • 2020
  • Verruca plana is a cutaneous infection caused by the human papilloma virus. Although various treatment methods are currently available, most have limitations due to the risk of complications such as hyperpigmentation, edema, and scarring. Moreover, as the infection tends to spread easily, new verrucae can potentially develop, and treatment procedure times tend to be lengthy. Thus, novel treatment methods are required. The 2790-nm wavelength erbium:yttrium-scandium-gallium-garnet (Er:YSGG) laser is a superficial resurfacing laser. Here, we present a case of a 25-year-old woman with multiple verrucae treated using a 2790-nm Er:YSGG laser. Compared to traditional methods, this novel laser is convenient, produces better cosmetic outcomes, and is less time-consuming; it is therefore suitable for the treatment of facial verruca plana.