• Title/Summary/Keyword: Laser tip

Search Result 163, Processing Time 0.021 seconds

Scribing and cutting a sapphire wafer by laser-induced plasma-assisted ablation

  • Lee, Jong-Moo
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.224-225
    • /
    • 2000
  • Transparent and hard materials such as sapphire are used for many industrial applications as optical windows, hard materials on mechanical contact against abrasion, and substrate materials for opto-electronic semiconductor devices such as blue LED and blue LD etc. The materials should be cut along the proper shapes possible to be used for each application. In case of blue LED, the blue LED wafer should be cut to thousands of blue LED pieces at the final stage of the manufacturing process. The process of cutting the wafer is usually divided into two steps. The wafer is scribed along the proper shapes in the first step. It is inserted between transparent flexible sheets for easy handling. And then, it is broken and split in the next step. Harder materials such as diamonds are usually used to scribe the wafer, while it has a problem of low depth of scribing and abrasion of the harder material itself. The low depth of scribing can induce failure in breaking the wafer along the scribed line. It was also known that the expensive diamond tip should be replaced frequently for the abrasion. (omitted)

  • PDF

Experimental Study on the Spray Behavior of Non-Esterification Biodiesel Fuel (비에스테르화 바이오디젤유의 분무거동에 대한 실험적 연구)

  • Choi, S.H.;Oh, Y.T.
    • Journal of ILASS-Korea
    • /
    • v.14 no.3
    • /
    • pp.117-121
    • /
    • 2009
  • Biodiesel fuel has different spray patterns, because viscosity and surface tension of biodiesel fuel are higher than that of diesel fuel. The diesel combustion is strongly controlled by the fuel spray behavior in combustion chamber. So, it was needed to understand the spay characteristics of non-esterification biodiesel fuel. In this study, the spray characteristics of non-esterification biodiesel fuel was investigated to confirm of an effect of WDP. The characteristics of fuel atomization was analyzed with SMD and span factor through laser diffraction particle analyzer (LDPA), and the process of spray injection was visualized through the visualization system composed of a halogen lamp and high speed camera. It was found that injection delay time and SMD of blended fuel with WDP get shoter and smaller than that of non-esterification biodiesel fuel.

  • PDF

Plasmon Assisted Deep-ultraviolet Pulse Generation from Amorphous Silicon Dioxide in Nano-aperture

  • Lee, Hyunsu;Ahn, Heesang;Kim, Kyujung;Kim, Seungchul
    • Current Optics and Photonics
    • /
    • v.2 no.4
    • /
    • pp.361-367
    • /
    • 2018
  • Ultrafast deep-ultraviolet (DUV) pulse generation from the subwavelength aperture of a plasmonic waveguide was investigated. The plasmonic nanofocusing of near-infrared (NIR) pulses was exploited to enhance DUV photoemission of surface third harmonic generation (STHG) at the amorphous $SiO_2$ dielectric. The generated DUV pulses which are successfully made from a nano-aperture using 10 fs NIR pulses have a spectral bandwidth of 13 nm at a carrier wavelength of 266 nm. This method is applicable for tip-based ultrafast UV laser spectroscopy of nanostructures or biomolecules

Study of Flow Field and Pressure Distribution on a Rotor Blade of HAWT in Yawed Flow Conditions

  • Maeda, Takao;Kamada, Yasunari;Okada, Naohiro;Suzuki, Jun
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.360-368
    • /
    • 2010
  • This paper describes the flow field and the blade pressure distribution of a horizontal axis wind turbine in various yawed flow conditions. These measurements were carried out with 2.4m-diameter rotor with pressure sensors and a 2-dimensional laser Doppler velocimeter for each azimuth angle in a wind tunnel. The results show that aerodynamic forces of the blade based on the pressure measurements change according to the local angle of attack during rotation. Therefore the wake of the yawed rotor becomes asymmetric for the rotor axis. Furthermore, the relations between aerodynamic forces and azimuth angles change according to tip speed ratio. By the experimental analysis, the flow field and the aerodynamic forces for each azimuth angle in yawed flow condition were clarified.

The Relationship between Pain Perception Scale and Keratinization Rate of Oral Mucosa to Nd-YAG Laser Stimulation in Burning Mouth Syndrome Patients (구강작열감 증후군 환자에서 Nd-YAG 레이저 조사에 대한 구강점막 부위의 통증 인지도와 점막세포 각화도와의 관계)

  • Kim, Ji-Yeon;Kim, Byung-Gook;Chung, Sung-Su
    • Journal of Oral Medicine and Pain
    • /
    • v.26 no.2
    • /
    • pp.161-171
    • /
    • 2001
  • In order to determine how oral mucosal change relates to inducing factors of burning mouth syndrome, the difference in pain perception scale and keratinization rate between burning mouth syndrome patients and normal subjects were investigated. Twenty patients (13 female, 7 male, mean age: 59 years), presenting in the Department of Oral Medicine, Chonnam National University Hospital were participated in this study. All subjects had been complaining of constant oral burning pain for more than a year, none took any strong analgesics, and none had oral mucosal lesions. Twenty volunteers (11 females, 9 males, mean age: 25 years) were also participated in this study as a control group. The control subjects had never had any symptoms of oral burning pain. A thermal stimulation using a Nd-YAG laser and cytological smear were carried out to anterodorsal part of tongue, tip of tongue, the left buccal mucosa, the lower lip mucosa and the chief complaint site. Stimulation of the dorsum of left hand was also carried out to contrast the mucosal area of burning mouth syndrome subjects and the control subjects. The laser output power could be adjusted from 0.75W to 4W. The pain perception scale of the burning mouth syndrome subjects were lower than in control subjects in the chief complaint area, the anterodorsal part of tongue and the buccal mucosa(p<0.01). The keratinization rate of burning mouth syndrome subjects, however, was higher keratinization rate than in normal subjects in the same area and lower lip mucosa(p<0.001). From above results, the anterodorsal part of tongue is the most appropriate site to use diagnostic laser stimulation. The higher level of keratinization and the lower level of thermal pain perception of the burning mouth syndrome subjects are explained as a protective mechanism against xerostomia and burning sensations. The application of Nd-YAG laser stimuli and cytological smear to oral mucosal surface could therefore be usefully employed as appropriate and standardized diagnostic tools for chronic orofacial pain subjects.

  • PDF

Self-Sensing Actuator Using an Ion-Polymer Metal Composite Based on a Neural Network Model (뉴럴네트워크 모델 기반의 IPMC 셀프 센싱 액추에이터)

  • Yoon, Jong-Il;Truong, Dinh Quang;Ahn, Kyoung-Kwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.12
    • /
    • pp.1865-1870
    • /
    • 2010
  • We develop an IPMC actuator with self-sensing behavior based on an accurate neural network model (NNM). The supplied voltage and voltage signals measured at two determined points on both sides of the IPMC sheet are used as inputs to the NNM. A CCD laser displacement sensor is installed in the rig for accurate measurement of the IPMC tip displacement that is used as the training output of the proposed NNM. Consequently, the NNM model is used to estimate the IPMC tip displacement; the NNM parameters are optimized by the collected input/output training data. The effectiveness of the model for the IPMC actuator is then verified by modeling results.

A Study on the Development of iGPS 3D Probe for RDS for the Precision Measurement of TCP (RDS(Robotic Drilling System)용 TCP 정밀계측을 위한 iGPS 3D Probe 개발에 관한 연구)

  • Kim, Tae-Hwa;Moon, Sung-Ho;Kang, Seong-Ho;Kwon, Soon-Jae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.6
    • /
    • pp.130-138
    • /
    • 2012
  • There are increasing demands from the industry for intelligent robot-calibration solutions, which can be tightly integrated to the manufacturing process. A proposed solution can simplify conventional robot-calibration and teaching methods without tedious procedures and lengthy training time. iGPS(Indoor GPS) system is a laser based real-time dynamic tracking/measurement system. The key element is acquiring and reporting three-dimensional(3D) information, which can be accomplished as an integrated system or as manual contact based measurements by a user. A 3D probe is introduced as the user holds the probe in his hand and moves the probe tip over the object. The X, Y, and Z coordinates of the probe tip are measured in real-time with high accuracy. In this paper, a new approach of robot-calibration and teaching system is introduced by implementing a 3D measurement system for measuring and tracking an object with motions in up to six degrees of freedom. The general concept and kinematics of the metrology system as well as the derivations of an error budget for the general device are described. Several experimental results of geometry and its related error identification for an easy compensation / teaching method on an industrial robot will also be included.

3D Face Recognition using Projection Vectors for the Area in Contour Lines (등고선 영역의 투영 벡터를 이용한 3차원 얼굴 인식)

  • 이영학;심재창;이태홍
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.2
    • /
    • pp.230-239
    • /
    • 2003
  • This paper presents face recognition algorithm using projection vector reflecting local feature for the area in contour lines. The outline shape of a face has many difficulties to distinguish people because human has similar face shape. For 3 dimensional(3D) face images include depth information, we can extract different face shapes from the nose tip using some depth values for a face image. In this thesis deals with 3D face image, because the extraction of contour lines from 2 dimensional face images is hard work. After finding nose tip, we extract two areas in the contour lilies from some depth values from 3D face image which is obtained by 3D laser scanner. And we propose a method of projection vector to localize the characteristics of image and reduce the number of index data in database. Euclidean distance is used to compare of similarity between two images. Proposed algorithm can be made recognition rate of 94.3% for face shapes using depth information.

  • PDF

Admittance Model-Based Nanodynamic Control of Diamond Turning Machine (어드미턴스 모델을 이용한 다이아몬드 터닝머시인의 초정밀진동제어)

  • Jeong, Sanghwa;Kim, Sangsuk
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.13 no.10
    • /
    • pp.154-160
    • /
    • 1996
  • The control of diamond turning is usually achieved through a laser-interferometer feedback of slide position. The limitation of this control scheme is that the feedback signal does not account for additional dynamics of the tool post and the material removal process. If the tool post is rigid and the material removal process is relatively static, then such a non-collocated position feedback control scheme may surfice. However, as the accuracy requirement gets tighter and desired surface cnotours become more complex, the need for a direct tool-tip sensing becomes inevitable. The physical constraints of the machining process prohibit any reasonable implementation of a tool-tip motion measurement. It is proposed that the measured force normal to the face of the workpiece can be filtered through an appropriate admittance transfer function to result in the estimated dapth of cut. This can be compared to the desired depth of cut to generate the adjustment control action in additn to position feedback control. In this work, the design methodology on the admittance model-based control with a conventional controller is presented. The recursive least-squares algorithm with forgetting factor is proposed to identify the parameters and update the cutting process in real time. The normal cutting forces are measured to identify the cutting dynamics in the real diamond turning process using the precision dynamoneter. Based on the parameter estimation of cutting dynamics and the admitance model-based nanodynamic control scheme, simulation results are shown.

  • PDF

THE MICROHARDNESS OF RESTORATIVE COMPOSITE AND DUAL-CURED COMPOSITE CEMENT UNDER THE PRECURED COMPOSITE OVERLAY (아르곤레이저를 이용한 레진인레이 하부의 레진 시멘트 및 광중합형 복합레진 중합)

  • Park, Sung-Ho;Lee, Chang-Kyu
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.109-115
    • /
    • 2000
  • This study was designed to evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay. For restorative materials, Z100 and Tetric Ceram were used. For dual cured composite cements, Variolink II((VL II) of three consistency (low, high, ultra high) were used. To determine the optimal microhardness of Z100, Tetric Ceram and Variolink II, each material was packed into the 1mm thickness teflon mold without composite overlay and light cured for 60 seconds. Then the microhardnesses of each sample were measured, averaged and regarded as optimal hardness of each material. To evaluate the microhardness of restorative composite resin and dual-cured composite resin cement which were light cured through the 1.5mm thickness composite overlay, the composites were packed into 1mm thickness teflon mold, coverd with celluloid strip, and then precured composite overlay which was made of Targis(Ivoclar/Vivadent, Liechtenstein) was positioned. 2 types of visible light curing machine, the power density of one of which was 400$mW/cm^2$ and the other was 900$mW/cm^2$, and one type of argon laser were used to cure the restorative composite and dual cured cement. For each group, 10 sample were assigned. The light curing tip was positioned over the composite overlay and light cured for 1min., 2min. or 3min with visible light curing machine or 15sec, 30 sec, 45sec, and 60 sec with argon laser. The Vickers hardnesses of upper and lower surface of Z100, Tetric Ceram, and 3 types of VL II cement were measured. When the 900 $mW/cm^2$ curing light was used, 2min. was needed for optimal curing of Z100 and Tetric Ceram. Variolink II did not be cured optimally even though the curing time was extended to 3min. When 400$mW/cm^2$ curing light was used, 3min. was necessary for Z100, whereas 3min. was not enough for Tetric Ceram. Variolink II was not cured optimally even though the curing time was extended to 3min. When argon laser was used, Z100, Tetric Ceram and Variolink II were not cured optimally in 60 seconds.

  • PDF