• Title/Summary/Keyword: Laser spot size

Search Result 114, Processing Time 0.037 seconds

Plasma spectroscopy aimed at quantifying the flame equivalence ratio (화염의 정성적 당량비 측정을 위한 Plasma Diagnostics에 관한 연구)

  • Lee, SeokHwan;Yoh, Jai-ick
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.99-101
    • /
    • 2013
  • The equivalence ratio is measured by LIBS(Laser-induced Breakdown spectroscopy) in hydrocarbon flame and high temperature (${\sim}3200^{\circ}C$) oxyhydrogen flame, where a stoichiometric mixture of hydrogen and oxygen is produced from water through electrolysis. The ratio of the hydrogen and oxygen (H/O) atomic lines intensities is used for quantitatively determining the quivalence ratio. laser energy is evaluated for determining the optimal condition for plasma diagnostics. The minimum laser energy for generating plasma in a laminar premixed hydrocarbon flame was about 70 mJ, whereas oxyhydrogen flame. consequently the irradiated spot of a lower density in high temperature oxyhydrogen flame gave rise to bigger plasma in size, thus limiting the spatial resolution of the LIBS measurement.

  • PDF

Micro Channel Fabrication Technology Using UV Laser Micromachining (UV 레이저 마이크로머시닝을 이용한 마이크로 채널 제작기술)

  • 양성빈;장원석;김재구;신보성;전병희
    • Transactions of Materials Processing
    • /
    • v.13 no.3
    • /
    • pp.216-224
    • /
    • 2004
  • In this study, we have developed a new UV$({\lambda}=355nm)$ laser micromachining technology by direct ablation method without masks. This technology allows that 3D micro parts can be fabricated rapidly and efficiently with a low price. And it has a benefit of reducing fabricating process simply. Due to micro parts' fabrication, such technologies need the control of XYZ stages with high precision, the design of optical devices to maintain micron spot sizes of laser beam and the control technology of laser focus. The developed laser manufacturing process for laser micromachining is that, after extracting coordinates of shape data from CAD model data, a beam path considering manufacturing features of laser beam is created by using genetic algorithm. This generated manufacturing process is sent to stage controller. In order to improve the surface quality of micro parts, we have carried out experiments on iteration manufacturing and beam step-over by using a minimum focus size. Moreover, we have fabricated a micro-channel through the developed laser micromachining technology and verified it through the results.

Ablation of Cr Thin Film on Glass Using Ultrashort Pulse Laser (극초단펄스 레이저에 의한 크롬박막 미세가공)

  • 김재구;신보성;장원석;최지연;장정원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.620-623
    • /
    • 2003
  • The material processing by using ultrashort pulse laser, in recently, is actively applying into the micro machining and nano-machining technology since ultrashort pulse has so faster than the time which the electrons energy absorbing photon energy is transmitted to surrounding lattice-phonon that it has many advantages in point of machining. The micro machining of metallic thin film on the plain glass is widely used in the fields such as mask repairing for semiconductor, fabrication of photonic crystal, MEMS devices and data storage devices. Therefore, it is important to secure the machining technology of the sub-micron size. In this research, we set up the machining system by using ultrashort pulse laser and conduct on the Cr 200nm thin film ablation experiments of spot and line with the variables such as energy, pulse number, speed, and so on. And we observed the characteristics of surrounding heat-affected zone and by-products appeared in critical energy density and higher energy density through SEM, and also examined the machining features between in He gas atmosphere which make pulse change minimized by nonlinear effect and in the air. Finally, the pit size of 0.8${\mu}{\textrm}{m}$ diameter and the line width of 1${\mu}{\textrm}{m}$ could be obtained.

  • PDF

Dependence of Mode Locked Yb-doped Fiber Laser Output on the Size of the Beam Incident upon a Semiconductor Saturable Absorber Mirror (반도체 포화 흡수체 거울에 입사되는 광의 크기에 따른 모드 잠금된 Yb 첨가된 광섬유 레이저 출력 특성)

  • Moon, Dong Joon;Kim, Myung Jin;Ahan, Cheol Yong;Kim, Nam Seong;Kim, Hyun Su
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.3
    • /
    • pp.103-107
    • /
    • 2012
  • We investigate the dependence of the output of a mode locked Yb-doped fiber laser on incident intra-cavity intensity on a semiconductor saturable absorber mirror (SESAM). To vary the incident intra-cavity intensity, we change the beam spot size on a SESAM by varying the focal length of a lens installed in the front of the SESAM.

Fabrication of Electrostatic Electron Lens for Electron Beam Microcolumn using the Laser Micromachining (레이저 미세가공 기술을 이용한 초소형 전자빔 장치용 정전장 전자렌즈의 제작)

  • Ahn, Seung-Jun;Kim, Dae-Wook;Kim, Ho-Seop;Kim, Yeong-Jeong;Lee, Yong-San
    • Korean Journal of Materials Research
    • /
    • v.11 no.9
    • /
    • pp.792-796
    • /
    • 2001
  • For electron beam lithography and SEM(scanning electron microscopy) applications, miniaturized electrostatic lenses called a microcolumn have been fabricated. In this paper, we report the fabrication technique for 20~30$\mu\textrm{m}$ apertures of electron lenses based on silicon and Mo membrane using an active Q-switched Nd:YAG laser. Experimental conditions of laser micromachining for silicon and Mo membrane are improved. The geometrical structures, such as the diameter and the preciseness of the micron-size aperture are dependent upon the total energy of the laser pulse train, laser pulse width, and the diameter of laser spot.

  • PDF

Focused Electrospray Deposition for Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

  • Jeong, Kyung-Hwan;Seo, Jong-Cheol;Yoon, Hye-Joo;Shin, Seung-Koo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2293-2298
    • /
    • 2010
  • Focused electrospray (FES) deposition method is presented for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. FES ion optics consists of two cylindrical focusing electrodes capped with a truncated conical electrode through which an electrospray emitter passes along the cylindrical axis. A spray of charged droplets is focused onto a sample well on a MALDI target plate under atmospheric pressure. The shape and size distributions of matrix crystals are visualized by scanning electron microscope and the mass spectra are obtained by time-of-flight mass spectrometry. Angiotensin II, bradykinin, and substance P are used as test samples, while $\alpha$-cyano-4-hydroxycinnamic acid and dihydroxybenzoic acid are employed as matrices. FES of a sample/matrix mixture produces fine crystal grains on a 1-3 mm spot and reproducibly yields the mass spectra with little shot-to-shot and spot-to-spot variations. Although FES greatly stabilizes the signals, the space charge due to matrix ions limits the detection sensitivity of peptides. To avoid the space charge problem, we adopted a dual FES/FES mode, which separately deposits matrix and sample by FES in sequence. The dual FES/FES mode reaches the detection sensitivity of 0.88 amol, enabling ultrasensitive of peptides by homogeneously depositing matrix and sample under atmospheric pressure.

A Study on the Surface Hardening of SCM4 Steel Using a Continuous Wave Nd:YAG Laser (연속파형 Nd:YAG 레이저를 이용한 SCM4강의 표면경화에 관한 연구)

  • Na, Gi-Dae;Shin, Byung-Heon;Shin, Ho-Jun;Yoo, Young-Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.24-32
    • /
    • 2007
  • Laser surface hardening is beneficially used for surface treatment of structural steel. Due to very rapid heating and cooling rates, structural low-alloy steel(SCM4) can be hardened as self quenching. The aim of this research project is to improve the influence of the process laser parameters: laser power, spot size, surface roughness, and traverse speed. The laser beam is allowed to scan on the surface of the workpiece at the constant power(1095W), varying the traverse speed at 0.3m/min, 0.5m/min and 0.8m/min. The optical lens with the elliptical profile is designed to obtain a wide surface hardening area with uniform hardness. From the results of the experiment, it has been shown that the stable hardness is about 600$\sim$700Hv, when the laser power, focal position and the traverse speed are P=1095W, z=0mm and v=0.3m/min.

Hybrid (CNC+Laser) Process for Polymer Welding (하이브리드 방식 (CNC+Laser)을 이용한 폴리머용접공정)

  • Yoo, Jong-Gi;Lee, Choon-Woo;Choi, Hae-Woon
    • Journal of Welding and Joining
    • /
    • v.28 no.3
    • /
    • pp.42-48
    • /
    • 2010
  • Polycarbonate (PC) and Acrylonitrile Butadiene Styrene (ABS) were welded by a combination of a diode laser and a CNC machining center. Laser beam delivered through the transparent PC and was absorbed in an opaque ABS. Polymers were melted and joined by absorbed and conducted heat. Experiments were carried out by varying working distance from 44mm to 50mm for the focus spot diameter control, laser input power from 10W to 25W, and scanning speed from 100 to 400mm/min. The weld bead and cross-section were analyzed for weld quality, and tensile results were presented through the joint force measurement. With focus distance at 48mm, laser power with 20W, and welding speed at 300mm/min, experimental results showed the best welding quality which bead size was measured to be 3.75mm. The shear strength at the given condition was $22.8N/mm^2$. Considering tensile strength of ABS is $43N/mm^2$, shear strength was sufficient to hold two materials. A single process was possible in a CNC machining system, surface processing, hole machining and welding. As a result, the process cycle time was reduced to 25%. Compared to a typical process, specimens were fabricated in a single process, with high precision.

Effect of Particle Contamination on Objective Lens in a CD-ROM Drive on Laser Diode Power and Photo Diode RF Signal (CD-ROM 드라이브의 대물렌즈 입자오염이 Laser Diode의 Power와 Photo Diode의 RF Signal에 미치는 영향)

  • Pae, Yang-Il;Hwang, Jung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1429-1434
    • /
    • 2003
  • A number of dust particles are intruded into ODD(Optical disk drive) due to the flow caused by disk rotation and are adhered to a lens or disk surface. The space between the disk and the lens is being reduced. Someone indicates the problems of this drive that are relatively small data storing capacity and slow access time. In recent, the problems of this optical disk drive mentioned above are being solved by adding the speed of the disk's revolution, making the actuator high-speed or light, and making the beam spot size smaller than making the space narrow between disk and lens. These particle contamination affects seriously RF Signal, readout signal in an ODD. Especially, the affected parts by a particle contamination in an ODD's readout signal are objective lens and media.

  • PDF

A Scanning electron microscopic study of the dentinal tubule obliteration effect by the different irradiations of a pulsed Nd:YAG laser (Nd:YAG 레이저의 조사방법의 차이에 따른 상아세관 폐쇄효과에 관한 주사전자현미경적 연구)

  • Ko, Eun-Young;Kim, Song-Wook;Yum, Chang-Yup;Kim, Byoung-Ock;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.4
    • /
    • pp.829-844
    • /
    • 1997
  • Dentin hypersensitivity must be one of the most frequent postoperative complaints in periodontal patients. Obliterating the open dentinal tubules or decreasing the diameter of their orifices would, therefore, be an objective of treatment for hypersensitive teeth. The purpose of this study was to evaluate the effect of a pulsed Nd:YAG laser irradiation on obliteration of dentinal tubules and to determine any difference according to irradiation methods. The 45 posterior teeth that had been extracted due to periodontal disease were initially treated with tetracycline HCI(100 mg/ml, 4 min.) to remove the smear layer after root planing. The root surfaces were then irradiated by a pulsed Nd:YAG laser(EL.EN.EN060, Italy) by different laser beam spot size and different exposure condition: ${\cdot}$ group 1: irradiated group by small spot(beam diameter=1mm, lW, 2 sec) ${\cdot}$ group 2: irradiated group by large spot(beam diameter=10mm, 1W, 200 sec) ${\cdot}$ group 3: irradiated group by gradual increase of watt (from 0.3W to 1.0W), beam diameter=4mm ${\cdot}$ group 4: irradiated group by fixed watt(1.0 W), beam diameter=4mm ${\cdot}$ control group: no irradiation but root planing and tetracycline HCI conditioning only. Additionally, the specimens were retreated with tetracycline HCI(100mg/ml, 4min.) to evaluate the stability of obliteration effect by Nd:YAG laser. Specimens were examined under the scanning electron microscope(JEOL, JSM-840A, Japan). Photomicrographs were taken at ${\times}4,000$ magnification and were analyzed statistically. The results were as follows: l. Scanning electron micrographs of root surface treated by tetracycline HCI alone(control group) showed widened, funnel-shaped dentinal tubules, while those of the root surface irradiated by various methods showed partially or completely obliterated dentinal tubules and various surface alterations, eg, flat, multiple pitted, melted and resolidified surface at the same energy density. 2. There was no significant difference in the obliteration effect of dentinal tubules between group 1 and group 2, and between group 3 and group 4(p>0.05). 3. The obliteration effect of dentinal tubules by a Nd:YAG laser irradiation was relatively stable to tetracycline HCI. The results demonstrate that a pulsed Nd:YAG laser irradiation within 1.0W, regardless of irradiation methods, can obliterate dentinal tubules effectively.

  • PDF