• Title/Summary/Keyword: Laser scanning unit

Search Result 78, Processing Time 0.025 seconds

Fabrication of Grooved Pattern for the Light Guide Plate of TFT-LCD with CO2 Laser (CO2 레이저 빔을 이용한 TFT-LCD 도광판의 패턴 제작에 관한 연구)

  • 김경동;백창일;송철기;안성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.147-150
    • /
    • 2002
  • A light guide panel is an element of the LCD backlight module that is often used for the display of compact electronic devices. In this study, a laser marking system is proposed to fabricate light guide panel, which can be replaced of other manufacturing methods such as silk printing, stamping, and v-cutting methods. The objectives of this research are the establishment of laser marking system, evaluation of laser marking parameters, understanding marking process, application to PMMA, reliability test and quality inspection. A 50W $CO_2$ laser (CW) was used to perform different experiments in which, the influence of some processing parameters (average power, scanning speed) on the geometry and quality of groove pattern was studied. The width of the etched grooves increases with increasing a laser power and decreasing a scan speed. In order to analyze surface characteristics and optical properties (luminance, uniformity), SEM photography and BM7 (luminance measuring system) were used. As a result, the optimal conditions of the process parameters were determined.

  • PDF

Fabrication of Three-Dimensional Micro Optical and Fluidic System Using Dual Stage Nanostereolithography Process (이중 스테이지를 이용한 대면적 3차원 광/유체 마이크로 디바이스 제작에 관한 연구)

  • Lim, Tae Woo;Yang, Dong-Yol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.552-557
    • /
    • 2015
  • The nanostereolithography process using a femtosecond laser has been shown to have strong merits for the direct fabrication of 2D/3D micro structures. In addition, a femtosecond laser provides efficient tools for precise micromachining owing to the advantages of a small and feeble heat effect zone. In this paper, we report an effective fabrication process of 3D micro optical and fluidic devices using nanostereolithography process composed of a dual stage system. Process conditions for additive and subtractive fabrication are examined. The Piezo stage scanning system is used for 3D micro-fabrication in unit area of sub-mm scale, and the motor stage is employed in fabrication on the scale of several mm. The misalignment between the pizeo- and motor- stages is revised through rotational transformation of CAD data in the unit domain. Here, the effectiveness of the proposed process is demonstrated through examples using 3D optical and microfluidic structures.

Investigation of Domestic and Foreign Forest Resource Management Status and Analysis of Laser Scanning Technology Application (국내외 산림자원관리 현황 조사 및 레이저 스캐닝 기술의 산림적용 방안 분석)

  • Park, Joon-Kyu;Lee, Keun-Wang
    • Journal of Digital Convergence
    • /
    • v.19 no.11
    • /
    • pp.391-396
    • /
    • 2021
  • In this study, items for forest policy and forest resource research in Austria, Japan, New Zealand, and Indonesia, which are major forest advanced countries, were investigated, and the applicability of point cloud data acquired through laser scanning was identified. Through the study, it was found that forest policies in developed countries are being pursued for the purpose of sustainable forest conservation and management, job creation, and timber productivity improvement, and that new technologies are being researched and applied to actual projects. Korea has a high proportion of forests compared to the national land area compared to major forestry developed countries, but the accumulation of trees is relatively low, so it is a time for scientific forest management to improve the accumulation of trees. To understand the applicability of laser scanning technology, a forest resource survey using point cloud data was conducted, and the diameter of breast height, height, number of trees per unit area were calculated, and the shape of the crown was identified. If field experiments and accuracy evaluations applying various laser scanning technologies are carried out in the future, it will be possible to present the quantitative improvement of forest resource survey using foil cloud.

Effect of Photothermal Therapy with Indocyanine Green in Multispecies Biofilm (Indocyanine Green을 이용한 광열 치료의 다종 우식원성 바이오필름에 대한 효과)

  • Kim, Myunghwan;Park, Howon;Lee, Juhyun;Seo, Hyunwoo;Lee, Siyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.48 no.1
    • /
    • pp.21-30
    • /
    • 2021
  • The purpose of this study is to investigate the antibacterial effects of indocyanine green (ICG) and near-infrared diode lasers on multispecies biofilms. Multispecies biofilms of Streptococcus mutans, Lactobacillus casei and Candida albicans were treated with different irradiation time using photosensitizer ICG and 808 nm near-infrared diode laser. Colony forming unit (CFU) was measured, and qualitative evaluation of biofilm was performed with confocal laser scanning microscopy (CLSM). Temperature measurement was conducted to evaluate photothermal effect. In the groups using ICG and diode laser, reduction in CFU was statistically significant, but the difference in antibacterial effect on L. casei and C. albicans with irradiation time was not significant, and similar results were confirmed with CLSM. Groups with ICG and diode laser showed higher temperature elevation than groups without ICG, and results of measured temperature were similar to the range of hyperthermia. In conclusion, ICG and near-infrared diode laser showed antibacterial effects on multispecies biofilms, but studies on protocol are necessary for clinical application.

Estimation of Hemispherical Aerodynamic Bearing using Experimental Method (반구형 공기동압 베어링의 실험적 평가)

  • 김영일
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.239-244
    • /
    • 1997
  • Recently, the high speed rotation and accuracy is needed in the field of electro-optic devices. But it is difficult for ball bearing to satisfy such conditions. So, we have developed the hemispherical type aerodynamic bearing for LSU(Laser Scanning Unit) motor. The hemispherical type aerodynamic bearing is able to support radial and axial load simultaneously. In this research, We have developed mass production method and tested the perromance of aerodynamic bearing in comparision with ball bearing at the speed of 23,000rpm. In the result, we proved that the properties of aerodynamic bearing is better than ball bearing's.

  • PDF

Effects of therapeutic ultrasound for contour asymmetry after liposuction, a case study

  • Wong, Yiu Ming
    • CELLMED
    • /
    • v.5 no.3
    • /
    • pp.19.1-19.2
    • /
    • 2015
  • This is a case report involving a novel setting of sonographic scan for thickness of superficial abdominal fat and a non-invasive approach for reduction of the fat thickness. A 38-year-old woman complained of her abdominal contour asymmetry after the laser-assisted liposuction performed two years ago. Compression-free sonographic scanning confirmed that her superficial abdominal fat was thicker in left side than that of right side. After 9 sessions of 40KHz therapeutic ultrasound, the contour asymmetry was reduced.

A Study on Performance Evaluation of 3-Axis Pipe Profile-Cutting Machine (3축 파이프 형상 절단기의 성능평가에 관한 연구)

  • Lho, Tae-Jung;Lee, Wook-Jin;Kim, Hwa-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.6
    • /
    • pp.1955-1960
    • /
    • 2010
  • A performance of CNC 3-axis pipe profile-cutting machine we developed was evaluated by measuring and verifying a positioning accuracy of its feeding unit and a cutting shape accuracy of pipe workpiece. The positioning accuracy was verified by comparing moving distance actuated by PLC motion controller with actual one measured by a laser interferometer. The cutting shape accuracy was also verified by comparing a cutting shape obtained through scanning and 3D modeling the pipe workpiece with that through CL data.

The Effects of Nd:YAG Laser Irradiation on the Root Surface;A Scanning Electron Microscopic Study (Nd:YAG 레이저 조사시 치근면에 미치는 효과에 관한 주사전자현미경적 연구)

  • Lee, Su-Jeong;Kim, Soo-Ah;Seo, Seok-Ran;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.3
    • /
    • pp.495-514
    • /
    • 1997
  • The purpose of this study was to evaluate the in vitro effects of Nd:YAG laser irradiation on removal of a root surface smear layer after root planing in comparison with Tetracycline HCl. The 60 extracted human teeth due to severe periodontal disease were vigorously scaled and root planed with Gracey curet. Thirty specimen($5{\times}5{\times}2mm$) were obtained from root planed surface of 30 human teeth and assigned randomly to one of three groups : root planed group(5 specimen), Tetracycline HCI group(5 specimen, burnished for 5 minutes), and Nd:YAG laser group(25 specimen, German Dental Laser, Fotona Twinlight). Nd:YAG laser group was divided into 4 subgroups according to power of 1W, 1.5W, 2W, 3W at frequency to 10Hz. The specimen were then fixed, and examed by Scanning electron microscopic study. 30 of 60 human teeth used to measurement of the intrapulpal temperature rise during laser irradiation. Laser-irradiated surface exhibited various surface texture from relative flat surface to irregular surface with patent dentinal tubules of various shape and size. In some area, the root surface alteration which are carbonization, pit and crater formation and melting and resolidification were observed. The number of exposed dentinal tubules per unit($100_{\mu}m^2$) on tetracycline HCI group was more than that in the laser group below 1.5W of power(150mJ/pulse) and was significantly less than that in laser group above 2W of power(200mJ/pulse)(P<0.OOl). As power increased the intrapulpal temperature rise also increased. The result suggested that the parameter which effectively remove root surface smear layer than tetracycline HCI may cause thermal damage to pulp and root surface alteration result from laser exposure would indicate need for additional instrumentation. Thus, Nd:YAG laser irradiation in these parameter may not be appropriate for clinical use as adjunct to conventional periodontal therapy.

  • PDF

Development on Tandem GMA Welding System using Seam Tracking System in Pipe Line (용접선 추적시스템을 적용한 탄뎀 원주 용접시스템 개발)

  • Lee, JongPyo;Lee, JiHye;Park, MinHo;Park, CheolKyun;Kim, IllSoo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.11
    • /
    • pp.1007-1013
    • /
    • 2014
  • In this study to improve the productivity, advantage Tandem circumferential weld process of seam tracking system was applied for the laser vision sensor. Weld geometry scanning laser vision sensor and PLC control unit are used to scan correct positioning of welding torch when the program is implemented so that it can correctly track the welding line. The welding experiment was conducted to evaluate the performance of laser vision seam tracking sensor in tandem welding process. The seam tracking several experiments was to determine the reliability of the system, welding experiments relatively good quality welding bead was confirmed. Furthermore, the PLC program for seam tracking was used to confirm the validity of the application of tandem welding process according to the benefits of increased productivity, which is expected to contribute to national competitiveness.