• Title/Summary/Keyword: Laser scanning system

Search Result 393, Processing Time 0.034 seconds

Calibration of Hydrographic Survey Multibeam System Using Terrestrial Laser Scanning and TS Surveying (지상 레이저 스캐닝과 TS 측량을 이용한 멀티빔 시스템의 검·보정)

  • Kim, Jin Soo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.3
    • /
    • pp.199-207
    • /
    • 2013
  • In hydrographic survey, data surveyed with multibeam system includes various errors due to multiple factors. These are corrected by a calibration called patch test, and if existing method is used, the test needs to be conducted for about 8 times for precise system calibration. For more prompt and precise multibeam system calibration, the exact offset of a ship was determined using terrestrial laser scanning and TS surveying, which was used as the initial input for the patch test. In the result, the error of closure was 0.001 m or less for TS surveying and backsight error was 0.005 m or less for scanning. All the surveying data based on the same local coordinate was converted into vessel reference coordinate during which R-square for all rotation angles was 0.99 or higher and standard deviation was 0.008 m or less. Finally, in a patch test using calculated offset of sensors and motion sensor offset, the offset of MBES transducer satisfied manual on hydrography only with 1-time calibration. With these results, it is thought that terrestrial laser scanning and TS surveying can fully be utilized for multibeam system calibration.

Design of Electromagnetically Driven Micro Scanning Mirror for Laser Animation System (레이저 디스플레이를 위한 전자력 구동 스캐닝 미러의 설계)

  • Lee, Kyoung-Gun;Jang, Yun-Ho;Yoo, Byung-Wook;Jin, Joo-Young;Lim, Yong-Geun;Kim, Yong-Kweon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.578-585
    • /
    • 2009
  • In this paper, we present the design of an electromagnetic scanning mirror with torsional springs. The scanning mirror consisting of torsional springs and electromagnetic coils was designed for the applications of laser animation systems. We analyzed and optimized three types of torsional springs, namely, straight beam springs (SBS), classic serpentine springs (CSS), and rotated serpentine springs (RSS). The torsional springs were analyzed in terms of electrical resistance, fabrication error tolerance, and resonance mode separation of each type using analytical formula or numerical analysis. The RSS has advantages over the others as follows: 1) A low resistance of conductors, 2) wide resonance mode separation, 3) strong fabrication error tolerance, 4) a small footprint. The double-layer coils were chosen instead of single-layer coils with respect to electromagnetic forces. It resulted in lower power consumption. The geometry of the scanning mirror was optimized by calculations; RSS turn was 12 and the width of double-layer coil was $100{\mu}m$, respectively. When the static rotational angle is 5 degrees, the power consumption of the mirror plate was calculated to be 9.35 mW since the resistance of the coil part and a current is $122{\Omega}$ and 8.75 mA, respectively. The power consumption of full device including the mirror plate and torsional springs was calculated to be 9.63 mW.

Scanning System and Reproduction of Adjustable Lower Dental Impression Tray (스캐닝 시스템과 하악용 가변형 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.3
    • /
    • pp.254-257
    • /
    • 2011
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable lower dental impression trays. Multiple impressions of a resin master model were made with custom, stock and new adjustable trays and vinyl polysiloxane impression material. The lower master model and resulting cast were compared using an dental scanning system. Each 3D image was superimposed onto the lower master model image and analyzed with custom software. Multiple measurements of the lower master model and casts were analyzed to determine the accuracy of tray types.

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

A study of the determination of off-set position for Nd:YAC laser welding between SCP steel sheet and STS304 sheet (Nd:YAG 레이저빔을 이용한 SCP 강판과 STS304강판 용접시 오프셋(off-set) 위치 결정에 관한 연구)

  • Yoon B. S.;Kim T. H.;Park G. Y.;Lee G. D.
    • Laser Solutions
    • /
    • v.7 no.2
    • /
    • pp.1-10
    • /
    • 2004
  • This work was attempted to join SCP sheet and STS304 sheet by using Nd:YAC laser beam. SCP sheet has good formability and low cost, while STS304 has excellent corrosion resistance and mechanical properties in high temp. In this experiment, butt joint type was used to develop the tailored blank welding for dissimilar steel. Sheets which have different thermal properties. Computer simulation was conducted to obtain the off-set position for efficient welding by considering laser power, scanning speed, focal length and basic properties. The result showed that the optimum thermal distribution was obtained when the laser beam was irradiated at $0.05{\sim}0.1$ mm off-set toward the SCP sheet side. The experiment was conducted based on the result of computer simulation to show the same optimum conditions. Optimum conditions were 3KW in laser beam power, 6m/min in scanning speed, -0.5mm in focal position, 0.1mm off-set toward SCP. Microhardness test, tensile test, bulge test, optical microscopy, EDS, and XRD were performed to observe the microstructure around fusion zone and to evaluate the mechanical properties of optimum conditions, The weld zone had high microhardness values by the formation of the martensitic structure. Tensile test measured the strength of welded region by vertical to strain direction and the elongation of welded region by parallel to strain direction. Bulge test showed $52\%$ formability of the original materials. Bead shape, grain size, and martensitic structure were observed by the optical microscopy in the weld zone. Detailed results of EDS, XRD confirmed that the welded region was connected of martensitic structure.

  • PDF

Development of a Laser-Generated Ultrasonic Inspection System by Using Adaptive Error Correction and Dynamic Stabilizer (적응적 에러 보정과 다이나믹 안정기를 이용한 레이저 유도 초음파 검사 시스템 개발)

  • Park, Seung-Kyu;Baik, Sung-Hoon;Park, Moon-Cheol;Lim, Chang-Hwan;Ra, Sung-Woong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.5
    • /
    • pp.391-399
    • /
    • 2005
  • Laser-generated ultrasonic inspection system is a non-contact scanning inspection device with high spatial resolution and wide bandwidth. The amplitude of laser-generated ultrasound is varied according to the energy of pulse laser and the surface conditions of an object where the CW measuring laser beam is pointing. In this paper, we correct the generating errors by measuring the energy of pulse laser beam and correct the measuring errors by extracting the gain information of laser interferometer at each time. h dynamic stabilizer is developed to stably scan on the surface of an object for an laser-generated ultrasonic inspection system. The developed system generates ultrasound after adaptively finding the maximum gain time of an laser interferometer and processes the signal in real time after digitization with high speed. In this paper, we describe hardware configuration and control algorithm to build a stable laser-generated ultrasonic inspection system. Also, we confirmed through experiments that the proposed correction method for the generating errors and measuring errors is effective to improve the performance of a system.

Three-dimensional Geometrical Scanning System Using Two Line Lasers (2-라인 레이저를 사용한 3차원 형상 복원기술 개발)

  • Heo, Sang-Hu;Lee, Chung Ghiu
    • Korean Journal of Optics and Photonics
    • /
    • v.27 no.5
    • /
    • pp.165-173
    • /
    • 2016
  • In this paper, we propose a three-dimensional (3D) scanning system based on two line lasers. This system uses two line lasers with different wavelengths as light sources. 532-nm and 630-nm line lasers can compensate for missing scan data generated by geometrical occlusion. It also can classify two laser planes by using the red and green channels. For automatic registration of scanning data, we control a stepping motor and divide the motor's rotational degree of freedom into micro-steps. To this end, we design a control printed circuit board for the laser and stepping motor, and use an image processing board. To compute a 3D point cloud, we obtain 200 and 400 images with laser lines and segment lines on the images at different degrees of rotation. The segmented lines are thinned for one-to-one matching of an image pixel with a 3D point.

Evaluation of Setup When Using C-Rad System in Radiotherapy (방사선치료 시 C-Rad system을 이용한 셋업의 평가)

  • Park, Eun-Tae;Ko, Seong-Jin;Choi, Seok-Yoon;Kim, Jung-Hoon;Kim, Chang-Soo;Kim, Dong-Hyun;Kang, Se-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.303-310
    • /
    • 2012
  • In radiotherapy, accurate patient positioning and set up are important factor that treatment can influence success. In generally, the 3-laser system is used when the patient set up. But today the body surface scanning system(C-Rad system) is trying to use. Compare and evaluate the C-Rad system and the 3-laser system to check availability. Head and neck that are no movement of internal organs and easy to apply fixation device are limited. Alderson Rando anthropomorphic phantom and 10 patients who have lesions of head and neck are targeted. C-RAD system's setup error mean and standard deviation are the X axis($0.55{\pm}0.51mm$), Y axis($-0.2mm{\pm}0.523mm$), Z axis($-0.85{\pm}0.587mm$) in the phantom study, and in the patient study X axis($-0.05{\pm}0.621mm$), Y axis($0.075{\pm}0.755mm$) Z axis($-1.025{\pm}0.617mm$). So C-RAD system is better than 3-laser system mostly, but C-RAD system's error rate is a little worse than 3-laser system in the Z axis. When radiation treatment of head and neck, body surface contour scanning system contribute to correct positioning and minimize the set up error.

Using Field Programmable Gate Array Hardware for the Performance Improvement of Ultrasonic Wave Propagation Imaging System

  • Shan, Jaffry Syed;Abbas, Syed Haider;Kang, Donghoon;Lee, Jungryul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.35 no.6
    • /
    • pp.389-397
    • /
    • 2015
  • Recently, wave propagation imaging based on laser scanning-generated elastic waves has been intensively used for nondestructive inspection. However, the proficiency of the conventional software based system reduces when the scan area is large since the processing time increases significantly due to unavoidable processor multitasking, where computing resources are shared with multiple processes. Hence, the field programmable gate array (FPGA) was introduced for a wave propagation imaging method in order to obtain extreme processing time reduction. An FPGA board was used for the design, implementing post-processing ultrasonic wave propagation imaging (UWPI). The results were compared with the conventional system and considerable improvement was observed, with at least 78% (scanning of $100{\times}100mm^2$ with 0.5 mm interval) to 87.5% (scanning of $200{\times}200mm^2$ with 0.5 mm interval) less processing time, strengthening the claim for the research. This new concept to implement FPGA technology into the UPI system will act as a break-through technology for full-scale automatic inspection.

Vibration Characteristics Analysis of the Disk-Type Stator in Ultrasonic Levitation System (초음파 부상장치의 디스크형 스테이터의 진동 특성 해석)

  • Jeong, Sang-Hwa;Choi, Suk-Bong;Cha, Kyoung-Rae;Kim, Hyun-Uk;Kim, Kwang-Ho;Park, Jun-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.264-268
    • /
    • 2005
  • In the semiconductor and optical industry the non-contact transportation is required for reducing the damages. The ultrasonic levitation is the solution of the problem. In this paper, the ultrasonic levitation system and 3 disk-type stator for levitating various object are proposed. The vibration modes of disks are analyzed with FEM and designed with the analysis results. The 3D vibration profiles of the disks are measured by Laser scanning vibrometer for verifying the vibration characteristics of the system and the amplitudes of the disks and the levitation heights of object are measured for evaluating the performance.

  • PDF