• Title/Summary/Keyword: Laser safety

Search Result 341, Processing Time 0.026 seconds

Effectiveness of a Fractional Picosecond 1,064-nm Laser in Improving Traumatic Scars with Depression

  • Ahn, Kwang Hyeon;Park, Eun Soo;Choi, Chang Yong
    • Medical Lasers
    • /
    • v.9 no.2
    • /
    • pp.179-183
    • /
    • 2020
  • The picosecond laser has been widely used to remove tattoos, and improve wrinkles, acne scarring, and pigmented scars. This study was performed to investigate the efficacy and safety of a 1,064-nm fractional picosecond laser treatment for depressed traumatic scars. A total of twenty Korean patients with depressed scars were treated with a 1,064-nm fractional picosecond laser at a two-week interval with a spot size of 3 mm, fluence of 3.5 to 5.5 J/cm2, and frequency of 2 Hz with a combination of microlens arrays. At 4 weeks after the final treatment, there was a statistically significant improvement in the modified Vancouver Scar Scale (mVSS) and the patient satisfaction score without any significant complication. A 1,064-nm fractional picosecond laser treatment is a safe and effective method to improve traumatic wound scars with depression.

A Numerical Analysis on Application of Laser Peening to Dissimilar Metal Welds in a Safety Injection Nozzle of Integral Reactor (일체형 원자로 안전주입 노즐 이종금속 용접부에 대한 레이저 피닝 적용의 수치 해석적 연구)

  • Seo, Joong-Hyun;Kim, Jong-Sung;Jhung, Myung-Jo;Ryu, Yong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.6
    • /
    • pp.599-608
    • /
    • 2012
  • A numerical analysis has been performed through implicit dynamic finite element analysis using the commercial package, ABAQUS in order to investigate effect of laser peening on welding residual stress mitigation of dissimilar metal welds in a safety injection nozzle of integral reactor. The implicit dynamic finite element analysis are compared with the previous experimental results. By comparison, it is identified that the implicit dynamic finite element analysis is valid for residual stress mitigation via laser peening. Implicit static finite element residual stress analysis has been performed for the dissimilar metal welds subject to inner repair welding. The analysis results represent that both axial and hoop residual stresses are tensile on inner surface of safety injection nozzle due to inner repair welding. Also Parametric study has performed to investigate effect of laser peening variables such as maximum impact pressure, duration time of pressure, spot diameter and peening direction on the welding residual stress mitigation. As a result, it is found that laser peening has the preventive maintenance effect to mitigate mainly residual stresses of region near inner surface.

A Pilot Study of Skin Resurfacing Using the 2,790-nm Erbium:YSGG Laser System

  • Rhie, Jong Won;Shim, Jeong Su;Choi, Won Seok
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • Background The erbium:yttrium scandium gallium garnet (Er:YSGG) laser differs from other laser techniques by having a faster and higher cure rate. Since the Er:YSGG laser causes an appropriate proportion of ablation and coagulation, it has advantages over the conventional carbon dioxide ($CO_2$) laser and the erbium-doped yttrium aluminum garnet (Er:YAG) laser, including heating tendencies and explosive vaporization. This research was conducted to explore the effects and safety of the Er:YSGG laser. Methods Twenty patients participated in the pilot study of a resurfacing system using a 2,790-nm Er:YSGG laser. All patients received facial treatment by the 2,790-nm Er:YSGG laser system (Cutera) twice with a 4-week interval. Wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture were measured. Results Study subjects included 15 women and five men. Re-epithelization occurred in all subjects 3 to 4 days after treatment, and wrinkle reduction, reduction in pigment inhomogeneity, and improvement in tone and texture within 6 months of treatment. Conclusions The 2,790-nm YSGG laser technique had fewer complications and was effective in the improvement of scars, pores, wrinkles, and skin tone and color with one or two treatments. We expect this method to be effective for people with acne scars, pore scars, deep wrinkles, and uneven skin texture and color.

The Effect of Laser Therapy for Stroke Patients : A Systematic Review and Meta-analysis (뇌졸중 환자에 대한 레이저 치료의 효과: 체계적 문헌고찰 및 메타분석)

  • Da-young An;Seung-ho Sun
    • The Journal of Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.45-64
    • /
    • 2024
  • Objectives: This study is purposed to investigate the effect and safety of laser therapy for stroke patients by systematic review and meta-analysis of the randomized controlled trials (RCTs). Methods: RCTs on the treatment of laser therapy for stroke patients were selected among the literature published from January 2000 to June 2022 in twelve domestic and foreign databases. The quality of the literature was evaluated using the Cochrane's Risk of Bias tool and RevMan 5.4 was used for the synthesis of results. Results: Total 2,598 patients with stroke were finally selected from 18 RCTs. Meta-analysis showed that laser therapy was effective in significantly improving activities of daily living (MBI), motor function (effective rate), upper motor function (FMA-UE), shoulder pain related factors (CGRP, ET-1, BK). Overall, the risk of bias was uncertain or low in the quality assessment of the literature. Conclusions: Although it is unclear that laser therapy is more effective than sham laser, laser therapy might be more effective in improving symptoms than conventional rehabilitation alone. Furthermore, no serious adverse events were founded in laser therapy studies. However, the quality of the selected literature was generally low. Therefore, further studies with high methodological quality on laser therapy for stroke patients would be required in the future.

The Characteristics of Soot at the Post-Flame Region in Jet Diffusion Flames Added Carbon Dioxide (이산화탄소가 첨가된 제트확산화염 후류에서의 매연 특성)

  • Ji, Jung-Hoon;Lee, Eui-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.9-13
    • /
    • 2010
  • An experimental study for characteristics of soot were conducted at the post-flame region in jet diffusion flames, where carbon dioxide was used as additives in oxidizer stream. Light-extinction method was performed using He-Ne laser with wave length at 632.8nm for the measurement of relative soot density and soot volume fraction with dimensionless extinction coefficient, $K_e$ and mass specific extinction coefficient, ${\sigma}_s$. To increase of resolution, laser light was modified for sheet-form using concave, convex lenses and slit. C/H ratio was introduced for quantitative analysis of soot growth which is expressed by carbonization and dehydrogen. Also transmission electron microscopy(TEM) was used for observation of morphological shape. The results show that the relative soot density in the post-flame region was lower when carbon dioxide was added in oxidizer stream because of reduction of flame temperature.

Laser Safety(1)

  • 한국광학기기협회
    • The Optical Journal
    • /
    • v.13 no.5 s.75
    • /
    • pp.78-89
    • /
    • 2001
  • PDF

Laser Safety(2)

  • 한국광학기기협회
    • The Optical Journal
    • /
    • v.13 no.6 s.76
    • /
    • pp.69-81
    • /
    • 2001
  • PDF

Irradiation Hardening Property of Inconel 718 Alloy produced by Selective Laser Melting (Selective Laser Melting 방식으로 적층제조된 Inconel 718 합금의 조사 경화 특성)

  • Joowon Suh;Sangyeob Lim;Hyung-Ha Jin;Young-Bum Chun;Suk Hoon Kang;Heung Nam Han
    • Journal of Powder Materials
    • /
    • v.30 no.5
    • /
    • pp.431-435
    • /
    • 2023
  • An irradiation hardening of Inconel 718 produced by selective laser melting (SLM) was studied based on the microstructural observation and mechanical behavior. Ion irradiation for emulating neutron irradiation has been proposed owing to advantages such as low radiation emission and short experimental periods. To prevent softening caused by the dissolution of γ' and γ" precipitates due to irradiation, only solution annealing (SA) was performed. SLM SA Inconel 718 specimen was ion irradiated to demonstrate the difference in microstructure and mechanical properties between the irradiated and non-irradiated specimens. After exposing specimens to Fe3+ ions irradiation up to 100 dpa (displacement per atom) at an ambient temperature, the hardness of irradiated specimens was measured by nano-indentation as a function of depth. The depth distribution profile of Fe3+ and dpa were calculated by the Monte Carlo SRIM (Stopping and Range of Ions in Matter)-2013 code under the assumption of the displacement threshold energy of 40 eV. A transmission electron microscope was utilized to observe the formation of irradiation defects such as dislocation loops. This study reveals that the Frank partial dislocation loops induce irradiation hardening of SLM SA Inconel 718 specimens.

A Study on the In-process Measurement of Metallic Surface Roughness in Cylindrical Grinding by Laser Beam (원통연삭가공시 레이저 빔을 이용한 금속 표면거칠기의 인프로세스 측정에 환한 연구)

  • 김희남;윤여권;이주상;김대욱
    • Journal of the Korean Society of Safety
    • /
    • v.9 no.3
    • /
    • pp.41-52
    • /
    • 1994
  • This paper deal with the design of noncontact In-process measurement system which measures the surface roughness during cylindrical grinding. The measuring system is extremely simple and the apparatus proposed is composed of a laser unit, photodetector and optical system. The experimental performance of the apparatus is satisfactory and good results are expected in the actual use. During operation, the surface of a workpiece Is continuously scanned by a laser beam. The experimental results show that the presence of chattering, loading and glazing can be detected sensitively along both circumferential and feed directions and the surface roughness value is obtained from the reading along the feed direction.

  • PDF