• Title/Summary/Keyword: Laser parameters

Search Result 980, Processing Time 0.028 seconds

Polarization multiplexing of holography memory in photopolymer (포토폴리머에서 편광방식을 이용한 홀로그래픽 메모리의 다중화)

  • Jeong, Hyeon-Seop;Kim, Nam;Sin, Chang-Won;Kim, Eun-Gyeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.07a
    • /
    • pp.275-276
    • /
    • 2007
  • A multiplex recording and reading technique in photopolymer are presented In order to record the polarization gratings, polarization-sensitive materials, in which linear birefringence is induced by irradiating the polarized light, are necessary. We checked orthogonal and independence of laser. The value of the photoinduced linear polarization had effect on diffraction properties in the holographic gratings. The grating strengths of two polarization are investigated and the relevant parameters for equal diffraction intensity readout are optimized.

  • PDF

Velocity and Temperature Profiles of Steam-Air Mixture on the Film Condensation (막응축 열전달에서 공기-수증기 혼합기체의 속도 및 온도분포)

  • 강희찬;김무환
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.10
    • /
    • pp.2675-2685
    • /
    • 1994
  • A study has been conducted to provide the experimental information for the velocity and temperature profiles of steam-air mixutre and to investigate their roles on the film condensation with wavy interface. Saturated gas mixture of steam-air was made to flow through the nearly horizontal$(4.1^{\circ})$ square duct of 0.1m width and 1.56m length at atmospheric pressure, and was condensated on the bottom cold plate. The air mass fraction in the gas mixture was changed from zero(W =0, pure steam) to one(W =1, pure air), and the bulk velocity was varied from 2 to 4 m/s. Water film was injected concurrently to investigate the effect of wavy interface on the condensation. The velocity and temperature profiles were measured by LDA system and thermocouples along the three parameters ; air mass fraction, mixture velocity and film flow rate. The profiles moved toward the interface with increasing steam mass fraction, mixture velocity and film flow rate. The Prandtl and Schmidt numbers were near one in the present experimental range, however there was no complete similarity between the velocity and temperature profiles of gas mixture. And the heat transfer characteristics and interfacial structure were coupled with each other.

Simulation and evaluation of fiber optics for hand-piece using ray tracing method (광선추적법을 이용한 핸드피스용 광섬유 광학계 시뮬레이션 및 특성 평가)

  • Park, J.H.;Kim, H.;Yang, B.C.;Lee, B.H.;Yoo, Y.J.;Kim, D.W.;Lee, C.W.;Lee, C.W.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1962-1963
    • /
    • 2002
  • The hand-piece fiber optics is applied to medical appliances such as glaucoma theraphy to focus semiconductor laser on the affected parts efficiently. In this paper, we evaluate optical properties such as beam power and radius of a hand-piece probe by experiments and we also simulate the hand-piece optics by ray tracing method in order to study major parameters to optimize focalization ability. As results, we show experimental and simulation results of the hand-piece optics and also summarize several requirements that have to be considered in optimizing the hand-piece optics.

  • PDF

A Study on Friction Behavior of Textured Surface in Unlubricated State (무윤활 상태에서 미세공이 가공된 표면의 마찰거동에 관한 연구)

  • Oh, Seok-Ju;Kim, Sung-Gi;Kim, Kyung-Woong
    • Tribology and Lubricants
    • /
    • v.25 no.4
    • /
    • pp.217-224
    • /
    • 2009
  • In this study, friction tests were carried out in order to investigate the friction behavior of textured surface in unlubricated state using ball-on-disk type apparatus. Test specimens were SUJ2 bearing steel ball and SM45C steel disk. Square arrays of circular micro-dimples were created on the surface of disk specimen by Nd:YAG Laser. Friction tests were performed for the disk specimen with various micro-dimple parameters and was also conducted for the variation of normal loads and relative velocities. The results showed that fiction coefficient of textured surface was lower than that of non-textured surface and the deeper depth of micro-dimple was, the lower friction coefficient obtained at the same diameter of micro-dimple in unlubricated state. Area density of micro-dimple had an effect on the friction coefficient. It was also found that friction coefficient generally decreased with the increase of normal load and relative velocity.

Fabrication of Er/Yb co-doped phosphate glass waveguides by potassium ion exchange (Er과 Yb이 첨가된 인산염 유리의 K 이온교환 공정을 통한 증폭용 광도파로 제조)

  • 김덕준;신장욱;박상호;김태흥;심재기;성희경
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.3
    • /
    • pp.202-205
    • /
    • 2000
  • One step thermal potassium ion exchange process was carried out to form optical channel waveguides in an ErNb co-doped phosphate glass. Flowing oxygen gas into KN03 melt during ion exchange was effective to prevent glass surface damage that causes an increase of waveguide propagation loss. Amplification characteristics of the waveguides were evaluated at $1.5{\mu}m$ signal wavelength with 980 om laser diode pump. A 45 mm long waveguide whose processing parameters had been optimized exhibited a small signal net gain of 7.5 dB at the launched pump power of 160 mW.160 mW.

  • PDF

Effect of Injector-driven Type on Spray Behavior and Fuel Atomization Characteristics (인젝터 구동 방식에 따른 분무 거동 및 분무 미립화 특성)

  • Park, Ji-Hong;Suh, Hyun-Kyu;Park, Sung-Wook;Kim, Jae-Wook;Lee, Chang-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • This study was performed to figure out spray behavior and fuel atomization characteristics of a piezo-driven injector and a solenoid-driven injector in the common-rail injection system under the same design parameters and test conditions. The process of spray injection was visualized by using the spray visualization system composed of a Nd:YAG laser and an ICCD camera. The atomization characteristics were investigated in terms of axial mean velocity, Sauter mean diameter(SMD) and droplet distributions obtained from a phase Doppler particle analyzer system. Compared with solenoid-driven injector, the piezo-driven injector has short injection delay and reaches quickly to the maximum injection value. Spray tip penetration shows some difference, however, spray angle of piezo-driven injector is wider than that of solenoid-driven injector. Sauter mean diameter of piezo-driven type injector is smaller than that of solenoid-driven type.

Faraday Rotation of the Hoya FR5 and FR4 Glasses at Cryogenic Temperature (저온에서 Hoya FR5 및 FR4 유리의 Faraday 회전)

  • 이현곤;원영희;이경수
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.352-358
    • /
    • 1995
  • Measurements of the Faraday rotation and magnetization of terbium-doped Hoya FR5 glass and cerium-doped Hoya FR4 glass have been made as a function of temperature T in the range 4.2 K -10 K and of magnetic field H of up to 80 kG at the $Ar^+$ laser wavelength of 514.5nm. The saturations of magnetization and Faraday rotation above H/T> $5kG.K^{-1}$ can be analyzed by the quantum theory of paramagnetism. Calculated parameters show that the large Verdet constant of $Ce^{3+}$ glass is due to the effective $4f\rightarrow5d$ electric dipole transition effect and that of $Tb^{3+}$ glass is due to the magnetization effect.effect.

  • PDF

Mode Behavior of Circular Vertical-Cavity Surface-Emitting Laser (원형 수직 캐비티 표면 광방출 레이저의 모드특성)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.1
    • /
    • pp.51-56
    • /
    • 2012
  • The resonance properties of circular vertical-cavity surface-emitting lasers (VCSELs) are studied by using a newly developed equivalent network approach. Optical parameters, such as the stop-band or the reflectivity of periodic Bragg mirrors and the resonance wavelength, are explored for the design of these structures. To evaluate the differential quantum efficiency and the threshold current density, a transverse resonance condition of circular modal transmission-line theory is also utilized. This approach dramatically reduces the computational time as well as gives an explicit insight to explore the optical characteristics of circular VCSELs.

Visualization of the Flow Pattern Between Co-rotating Disks in Shroud (원통형 케이스 내의 동시회전 디스크 내부 유동패턴의 가시화)

  • Kong, Dae-Wee;Joo, Won-Gu
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1661-1665
    • /
    • 2004
  • Hard disk drives (HDD) in computer are used extensively as data storage capacity. The trend in the computer industry to produce smaller disk drives rotating at higher speeds requires an improved understanding of fluid motion in the space between disks. Laser sheet and digital camera was used for 2-dimensional visualization of the unsteady flow between co-rotating disks in air with a cylindrical enclosure (or shroud). Geometric parameters are gap height (H) between disks, and gap distance (G) between disk tip and shroud. The lobe-structured boundary between inner region and outer region was detected by inserted particles, and the number of dominant vortices was determined clearly It is found from flow visualization that the number of vortex cells can be correlated with Reynolds number based on H which is defined as $Re_H={\Omega}RH/v$ ranging from $7.96{\times}10^2$ to $1.43{\times}10^4$, and decreases as the disk speed increases. The lobe pattern by vortex cells is changed to a circular pattern for the wide gap than narrow one.

  • PDF

Precise Detection of Coplanar Checkerboard Corner Points for Stereo Camera Calibration Using a Single Frame (스테레오 카메라 캘리브레이션을 위한 동일평면 체커보드 코너점 정밀검출)

  • Park, Jeong-Min;Lee, Jong-In;Cho, Joon-Bum;Lee, Joon-Woong
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.21 no.7
    • /
    • pp.602-608
    • /
    • 2015
  • This paper proposes an algorithm for precise detection of corner points on a coplanar checkerboard in order to perform stereo camera calibration using a single frame. Considering the conditions of automobile production lines where a stereo camera is attached to the windshield of a vehicle, this research focuses on a coplanar calibration methodology. To obtain the accurate values of the stereo camera parameters using the calibration methodology, precise localization of a large number of feature points on a calibration target image should be ensured. To realize this demand, the idea with respect to a checkerboard pattern design and the use of a Homography matrix are provided. The calibration result obtained by the proposed method is also verified by comparing the depth information from stereo matching and a laser scanner.