• 제목/요약/키워드: Laser induced fluorescence

검색결과 248건 처리시간 0.024초

Two-color LIF 기법을 이용한 단열체가 있는 밀폐계 내에서의 자연대류에 관한 실험적 연구 (Experimental study on the natural convection in an enclosure with an adiabatic body using the two-color LIF method)

  • 권수현;정은호;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 추계학술대회 논문집
    • /
    • pp.104-107
    • /
    • 2004
  • Most of the previous studies on natural convection were based on the numerical analysis, and some experimental studies considered the classic case of thermal convection. In this study, an adiabatic square body was located at the center of an enclosure between the bottom hot and top cold walls. And the measurement of the detailed temperature fields was conducted by the method of two-color Laser Induced Fluorescence using a Nd:Yag laser. As a result, heat transfer characteristics of natural convection with an adiabatic body was estimated as a function of time over a range of Rayleigh numbers.

  • PDF

형광 나노 포러스 박막을 이용한 표면 온도 센서의 제작 및 성능 연구 II (Fabrication and Performance Investigation of Surface Temperature Sensor Using Fluorescent Nanoporous Thin Film II)

  • 김현정;유재석;박진일
    • 설비공학논문집
    • /
    • 제25권12호
    • /
    • pp.674-678
    • /
    • 2013
  • We present a non-invasive technique to the measure temperature distribution in nano-sized porous thin films by means of the two-color laser-induced fluorescence (2-LIF) of rhodamine B. The fluorescence induced by the green line of a mercury lamp with the makeup of optical filters was measured on two separate color bands. They can be selected for their strong difference in the temperature sensitivity of the fluorescence quantum yield. This technique allows for absolute temperature measurements by determining the relative intensities on two adequate spectral bands of the same dye. To measure temperature fields, Silica (SiO2) nanoporous structure with 1-um thickness was constructed on a cover glass, and fluorescent dye was absorbed into these porous thin films. The calibration curves of the fluorescence intensity versus temperature were measured in a temperature range of $10-60^{\circ}C$, and visualization and measurement of the temperature field were performed by taking the intensity distributions from the specimen for the temperature field.

평면 레이저 유도 형광법(PLIF)을 이용한 $CH_4/O_2N_2$ 예혼합화염의 NO 농도 분포 가시화에 관한 연구 (A Study on the Visualization of NO Concentration Distributions in $CH_4/O_2N_2$ Premixed Flames by PLIF)

  • 박경석;이세환
    • 한국분무공학회지
    • /
    • 제6권3호
    • /
    • pp.1-7
    • /
    • 2001
  • In this study, quantitative measurement of nitric oxide concentration distributions visualization were investigated in the laminar $CH_4/O_2N_2$ nixed flame by Planar laser-induced fluorescence(PLIF). The NO A-X (0,0) vibrational band around 226nm was excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interference from Rayleigh scattering and $O_2$ fluorescence. The measurements were taken in $CH_4/O_2N_2$ premixed flame with equivalence ratios varying from $1.0{\sim}1.6$, and a fixed flow rate of 3slpm. NO was found to produce primarily between an inner premixed and an outer nonpremixed flame front, and total NO concentration is raised when equivalence ratios increase. These results suggest that prompt NO is likely to contribute to MO formation in $CH_4/O_2N_2$ premixed flame. Furthermore, this trend was well matched with previous works.

  • PDF

레이저 유도 형광법(LIF)을 이용한 버너 화염의 NO 농도측정에 관한 연구 (A Study on Measurement of NO Concentrations in Burner Flames by LIF)

  • 박경석;김성욱
    • 한국분무공학회지
    • /
    • 제7권4호
    • /
    • pp.42-49
    • /
    • 2002
  • In this study, quantitative measurement of nitric oxide concentration distributions were investigated in the laminar CH4/O2/N2 premixed flame by laser-induced fluorescence (LIF). The NO A-X (0,0) vibrational band around 226nm was excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interference from Rayleigh scattering and O2 fluorescence. The measurements were taken in CH4/O2/N2 premixed flame with equivalence ratios varying from $1.0{\sim}1.6$, and a fixed flowrate of 5slpm. NO was found to produce primarily between an inner premixed and an outer nonpremixed flame front, and total NO concentration is raised when equivalence ratios increase. These results suggest that prompt NO is likely to contribute to NO formation in CH4/O2/N2 premixed flame. Furthermore, this trend was well matched with previous works.

  • PDF

레이저 유도 형광법(LIF)을 이용한 층류 메탄 예혼합 화염내 NO 농도측정에 관한 연구 (A Study on Measurement of NO Concentrations in Laminar Premxied $CH_4/O_2/N_2$ Flames by LIF)

  • 김성욱;진성호;김경수;박경석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.156-161
    • /
    • 2000
  • In this study, quantitative nitric oxide concentration distributions are investigated in the post-flame zone of laminar premixed $CH_4/O_2/N_2$, flames by laser-induced fluorescence (LIF). The measurements are taken in flames for different equivalence ratios varying from $0.8{\sim}1.4$, and flow rate is fixed as 5slpm. The NO A-X (0,0) vibrational band around 226 nm is excited using a XeCl excimer-pumped dye laser. Selecting an appropriate NO transition minimizes interferences from Rayleigh scattering and $O_2$ fluorescence. NO concentration is rised when equivalence ratios increase at different vertical distances form nozzle tip. In any case, the maximum NO concentration reaches the maximum in reaction zone.

  • PDF

비증발 디젤분무의 분열과 미립화 과정의 가시화 (Visualization of Breakup and Atomization Processes in Non-evaporating Diesel Sprays)

  • 원영호;김우태
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.25-31
    • /
    • 2004
  • Two-dimensional laser visualization methods have been used in the study of breakup and atomization processes of non-evaporating diesel sprays. A single-hole spray injected into a quiescent atmospheric environment was visualized by the LIF(Laser Induced Fluorescence) and scattering technique. The LIF technique could be implemented to take the images which are magnified enough to show the shape of liquid ligaments and small droplets. The spontaneous scattering and fluorescent images of sprays were also taken to investigate the atomization of droplets. In the tip and periphery of a spray. the scattering light is bright and the ratio of fluorescent/scattering intensity is lower. This characteristics indicate the very high number density of small droplets which are well atomized.

마이크로 레이저 평면빔을 이용한 마이크로채널 내에서의 Micro-LIF 측정 (Micro-LIF Measurement in a Micro-channel Using an Micro Laser Light Sheet)

  • 윤상열;김재민;김수헌;김경천
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1540-1545
    • /
    • 2004
  • Measurement of concentration fields in a micro-channel is the crucial technology in the area of Lab-on-a-chip to be used for various bio-chemical applications. It is wel-known that the only possible way to measure the concentration field in the micro-channel is using micro-LIF(Laser Induced Fluorescence) method. However, an accurate concentration field at a given cross plane in a micro-channel has not been made so far due to the limit of light illumination. The present study demonstrates a novel method to provide an ultra thin laser sheet beam having 5 microns thickness by a micro focus laser line generator. Nile Blue A was used as fluorescent dye for LIF measurement. The laser sheet beam illuminates an exact plane of concentration measurement in the micro-channel to increase the signal to noise ratio and reduce the depth uncertainty considerably.

  • PDF

산화제 결핍 분위기에서의 층류 확산화염내 OH, PAHs 및 그을음 분포 (OH, PAHs and Soot Ditribution in a Laminar Diffusion Flame Under Oxidizer Deficient Ambience)

  • 심성훈;신현동
    • 대한기계학회논문집B
    • /
    • 제26권10호
    • /
    • pp.1348-1354
    • /
    • 2002
  • We investigate the flame behavior and spatial distribution of OH, PAHs and soot in a confined buoyant diffusion flame with decrease of the coflowing air flow rate. Direct photographs and Schlieren images represent that flame is Ally occupied by blue flame and becomes unstable, which is partially detached to the fuel nozzle tip in a near extinction flame under extremely reduced oxidizer condition. Laser induced fluorescence profiles clearly shows that OH is still generated in near-extinction flame, although intensity becomes weak with decreasing air flow rate. But soot scattering image cannot be seen any more in an oxidizer deficient ambience and simultaneously the PAHs are widely distributed downstream. These results are due to that a decrease of oxygen concentration in the combustion chamber leads to a temperature drop of flame, as a consequence, to a delay in soot growth and to a expanding of the PAHs, as soot precursors.

아음속 수직분사제트에서 액적크기 특성에 대한 실험적 연구 (An Experimental Study on Droplet Size Characteristics of Liquid Jets in Subsonic Crossflow)

  • 김민기;손진관;김진기;황용석;윤영빈
    • 한국분무공학회지
    • /
    • 제12권2호
    • /
    • pp.115-122
    • /
    • 2007
  • The spray characteristics and drop size measurements have been experimentally studied in liquid jets injected into subsonic crossflow. With water as fuel injection velocity, injection angle and atomize. internal flows were varied to provide of jet operation conditions. The injector internal flow was classified as three modes such as a non-cavitation flow, cavitation, and hydraulic flip flows. Pulsed Shadowgraph Photography measurement was used to determine the spatial distribution of the spray droplet diameter in a subsonic crossflow of air. And this study also obtains the SMD (Sauter Mean Diameters) distribution by using Planar Liquid Laser Induced Fluorescence technique. The objectives of this research are get a droplet distributions and drop size measurements of each condition and compare with the other flow effects. As the result, This research has been showned that droplet size were spatially dependent on air-stream velocity, fuel injection velocity, injection angle effects, and normalized distance from the injector exit length(x/d, y/d). There are also different droplet size characteristics between cavitation, hydraulic flip and the non-cavitation flows.

  • PDF

평면 레이저유도 형광법을 이용한 부상화염의 특성 연구 (Study on the characteristics of laminar lifted flames using planar laser induced fluorescence technique)

  • 이병준;정석호;한재원
    • 대한기계학회논문집B
    • /
    • 제21권11호
    • /
    • pp.1393-1402
    • /
    • 1997
  • Characteristics of the lifted flame which is generated by issuing of the fuel through the miniature nozzle, d = 0.164 mm, are studied using the planar laser induced fluorescence technique. OH radical is excited on the $Q_{1}$(8) line of the $A^{2}$.SIGMA.$^{+.leq.X2}$ .PI.(1, 0) band transition (283.55 nm) and LIF signals are captured at the bands of (0, 0) and (1, 1) transition (306 ~ 326 nm) using the filters and ICCD camera. Hydroxyl radical (OH) profile for nozzle attached flame shows that OH radical populations at the flame sides and flame tip are larger than those at the base. But for the lifted flame (tribrachial flame) case, those are larger at the flame base than at the flame tip and flame sides. The OH radical is more dense near the center line of flame base at the blowing out. This fact proves the Chung and Lee's blowout theory-blowout occurs when the flame is anchored at the flame axis. axis.