• 제목/요약/키워드: Laser imager

검색결과 23건 처리시간 0.021초

Laser Doppler Perfusion Imager (LDPI)로 측정한 자외선 조사부위의 혈류량과 최소 홍반량(MED)과의 상관관계 (Relationship between UV-induced MED and Perfusion Value Assessed by Laser Doppler Perfusion Imager)

  • 김남수;이경훈
    • 대한화장품학회지
    • /
    • 제31권3호
    • /
    • pp.259-263
    • /
    • 2005
  • 혈류량은 자외선 조사량 증가에 비례하여 증가되는 양상을 보였다. 홍반을 유발하는데 필요한 자외선량(MED)의 차이가 혈류량의 변화와 어떠한 관계가 있는지를 알아본 실험에서, MED가 30 mJ로 비교적 낮았던 피험자들의 경우, 혈류량은 MED를 지나서 급격하게 증가되는 양상을 관찰하였으나 30 mJ 이상에서 MED가 관찰되었던 피험자들의 경우에는 자외선 조사에 따른 혈류량의 변화가 급격한 변화 없이 계속 완만하게 증가되는 양상을 보였다.

Laser imager의 성능관리에 대한 연구

  • 이형진;인경환;이원홍;김건중
    • 대한디지털의료영상학회논문지
    • /
    • 제3권1호
    • /
    • pp.126-132
    • /
    • 1997
  • Purpose : To apply to Program of Auto processor quality control after comparison of Film density variations with amendments to Auto density by using Check density program and Adjust density program of calibration mode into the Laser imager. Methods : Observe Check and Adjust density variations on the Control chart with standard step and value during seven months from December, 1995 to June, 1956 extending twice a week. (1) Measure density value on the steps after printing out 17-step sensitometric pattern of the Check density program. (2) In the same way, measure density values after amending density by using Adjust density program If they are exceeding allowable error limit. Results : In case of Check density program, the exceeding limit rates of Density difference(DD) and Middle density(MD) are: FL-IM3543 DD=75%. MD=72.5%, FL-IMD DD=0%. MD=30.8%(14.5%) After amending density by using Adjust density program, the exceeding limit rates of all both Laser imager were zero percent. The standard deviations are show lower FL-IM D than FL-IM3543 on the Check density control chart, but higher on the Adjust density control chart. Conclusion : (1) Check density variations by printingout sensitometric pattern extending once a week at least for quality control of the Laser imager. (2) In case of a dusty place, check the Laser beam transmission after cleaning Laser optical unit extending once a month. (3) Be sure to measure and check density values by using adjust density program if they are exceeding allowable error limit. (4) Maintain much better film density by performing the adjust density program even if check density values are existed within normal limit.

  • PDF

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제22권2호
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

Corrosion visualization under organic coating using laser ultrasonic propagation imaging

  • Shi, Anseob;Park, Jinhwan;Lee, Heesoo;Choi, Yunshil;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • 제29권2호
    • /
    • pp.301-309
    • /
    • 2022
  • Protective coatings are most widely used anticorrosive structures for steel structures. The corrosion under the coating damages the host material, but this damage is completely hidden. Therefore, a field-applicable under-coating-corrosion visualization method has been desired for a long time. Laser ultrasonic technology has been studied in various fields as an in situ nondestructive inspection method. In this study, a comparative analysis was carried out between a guided-wave ultrasonic propagation imager (UPI) and pulse-echo UPI, which have the potential to be used in the field of under-coating-corrosion management. Both guided-wave UPI and pulse-echo UPI were able to successfully visualize the corrosion. Regarding the field application, the guided-wave UPI performing Q-switch laser scanning and piezoelectric sensing by magnetic attachment exhibited advantages owing to the larger distance and incident angle in the laser measurement than those of the pulse-echo UPI. Regarding the corrosion visualization methods, the combination of adjacent wave subtraction and variable time window amplitude mapping (VTWAM) provided acceptable results for the guided-wave UPI, while VTWAM was sufficient for the pule-echo UPI. In addition, the capability of multiple sensing in a single channel of the guided-wave UPI could improve the field applicability as well as the relatively smaller size of the system. Thus, we propose a guided-wave UPI as a tool for under-coating-corrosion management.

초음파전파영상화 시스템을 이용한 필라멘트 와인딩 복합재 수소 연료 탱크의 손상 가시화 (Damage Visualization of Filament Wound Composite Hydrogen Fuel Tank Using Ultrasonic Propagation Imager)

  • 이정률;정효미;트루옹 탄 충;신혜진;박재윤
    • Composites Research
    • /
    • 제28권4호
    • /
    • pp.143-147
    • /
    • 2015
  • 알루미늄 혹은 플라스틱 라이너에 탄소섬유를 감아서 성형하는 복합재 압력용기가 수소 자동차의 수소연료 탱크로 사용이 확대됨에 따라 사용 시 안전에 대한 규정 제정이 필요하며 그 규정을 뒷바침 할 수 있는 검사장비와 기술 역시 개발되어야 한다. 자동차에 장착하기 전에 제작결함 평가를 통해 수소 자동차에 장착되어야 하고, 취급 중 발생하는 이벤트에 대해서도 고속 자동화 검사를 통해 자동차 정비소의 정비인력, 즉 비파괴평가 전문가가 별도의 교육을 받지 않았어도 즉시 충격과 같은 손상을 평가할 수 있어야 한다. 위 요소는 수소자동차의 대중화를 위해 매우 중요한 기술적 허들이다. 본 연구에서는 수소연료탱크의 충격손상을 검사하는 방법으로 레이저 초음파 기술을 제안하며 충격손상을 탈 부착형 센서헤드를 가진 초음파전파영상화 시스템으로 가시화할 수 있음을 증명한다. 또한 제안한 초음파전파영상화 시스템의 성능은 수소자동차가 대중화되더라도 현장기술로 채택될 수 있음을 뒷받침한다.

온-보드 영상장치를 이용한 총체적 셋업의 정확성 분석 (Analysis of Overall Setup Accuracy Using On-Board Imager��)

  • 마선영;임상욱;강수만;정태식
    • 한국의학물리학회지:의학물리
    • /
    • 제22권2호
    • /
    • pp.67-71
    • /
    • 2011
  • 본 연구에서는 방사선사를 포함한 레이저, 갠트리 및 온-보드 영상장치의 총체적 셋업의 정확성을 평가하고자 하였다. 경험이 많은 방사선사에게 매일 아침 마커블록을 카우치의 Lock bar 시스템에 고정하고 마커블록을 레이저 중심에 맞추도록 하였다. 71일간 마커블록을 2D/2D 정합으로 위치를 보정하기 위하여 $0^{\circ}$ and $270^{\circ}$ 각도에서 한 쌍의 kV 영상을 획득하였다. 정합이 되었을 때 원격으로 카우치를 조정하여 셋업에러를 보정하고 보정 값은 저장하였다. 상하방향(vertical)과 앞뒤방향(longitudinal) 평균오차를 분석한 결과 상하방향은 0.65, 앞뒤방향은 0.66으로 나타났으며 반면에 좌우방향(lateral)은 0.01으로 나타났다. 상하방향과 앞뒤방향의 p 값은 모두 0.00으로 통계적으로 유의하게 나타났으며, 좌우방향에서는 p 값이 0.829로 나타나 계통오차를 발견하기 어려웠다. 총체적 셋업평가방법은 일간으로 시행하기에 유용하고 편리하였다. 그러나 계통오차를 줄이기 위해서 여전히 레이저와 OBI의 일간 점검은 필요하다.