• Title/Summary/Keyword: Laser absorption spectroscopy

Search Result 118, Processing Time 0.032 seconds

Measurement of Sulfur Dioxide Concentration Using Wavelength Modulation Spectroscopy With Optical Multi-Absorption Signals at 7.6 µm Wavelength Region (7.6 µm 파장 영역의 다중 광 흡수 신호 파장 변조 분광법을 이용한 이산화황 농도 측정)

  • Song, Aran;Jeong, Nakwon;Bae, Sungwoo;Hwang, Jungho;Lee, Changyeop;Kim, Daehae
    • Clean Technology
    • /
    • v.26 no.4
    • /
    • pp.293-303
    • /
    • 2020
  • According to the World Health Organization (WHO), air pollution is a typical health hazard, resulting in about 7 million premature deaths each year. Sulfur dioxide (SO2) is one of the major air pollutants, and the combustion process with sulfur-containing fuels generates it. Measuring SO2 generation in large combustion environments in real time and optimizing reduction facilities based on measured values are necessary to reduce the compound's presence. This paper describes the concentration measurement for SO2, a particulate matter precursor, using a wavelength modulation spectroscopy (WMS) of tunable diode laser absorption spectroscopy (TDLAS). This study employed a quantum cascade laser operating at 7.6 ㎛ as a light source. It demonstrated concentration measurement possibility using 64 multi-absorption lines between 7623.7 and 7626.0 nm. The experiments were conducted in a multi-pass cell with a total path length of 28 and 76 m at 1 atm, 296 K. The SO2 concentration was tested in two types: high concentration (1000 to 5000 ppm) and low concentration (10 ppm or less). Additionally, the effect of H2O interference in the atmosphere on the measurement of SO2 was confirmed by N2 purging the laser's path. The detection limit for SO2 was 3 ppm, and results were compared with the electronic chemical sensor and nondispersive infrared (NDIR) sensor.

Study on Gas Concentration Measurement of O2 and NO Using Calibration-free Wavelength Modulation Spectroscopy in Visible and Mid-Infrared Region (가시광선과 중적외선 영역의 무보정 파장 변조 분광법을 이용한 O2와 NO 가스 농도 측정에 관한 연구)

  • Aran Song;Geunhui Ju;Kanghyun Kim;Jungho Hwang;Daehae Kim;Changyeop Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.70-77
    • /
    • 2023
  • Air environment regulations have been strengthened due to increasing air pollutant emissions, the target of reducing emissions has increased and interest in gas measurement methods is also increasing. The sampling method is mainly used, but due to the spatial and temporal measurement limitations, the laser absorption spectroscopy which is a real-time and in-situ method is in the spotlight. In this study, we studied the wavelength modulation spectroscopy and described the calibration-free algorithm. The developed algorithm was modified to reflect 46 multi-absorption lines and was applied to light absorption signal analysis in visible and mid-infrared regions. In addition, the difference between the modulation parameters of laser was analyzed. As a result of reviewing the performance through O2 and NO gas measurement experiments of various concentration conditions, the linearity was R2O2=0.99999 and R2NO=0.99967.

APPLICATION OF A MULTI-WAVELENGTH NIR DIODE LASER ARRAY FOR NON-DESTRUCTIVE FOOD ANALYSIS

  • Tauscher, Bernhard;Butz, Peter;Lindauer, Ralf
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.3123-3123
    • /
    • 2001
  • Near infrared (NIR) spectroscopy has become a widely used method in food and beverage analysis because of its speed, accuracy and the simplicity of sample preparation. One of the basic requirements of NIR instruments is a wide dynamic range if weak, or small, absorption changes or concentrations are to be measured. Thus the instrument must be sufficiently luminous, and efficient, to enable measurements to be made in a reasonably short time, as for some applications (e.g. sorting) short response times are essential. Diode lasers function the same way as lasers but linewidths are not as narrow as typical lasers. In this work an array of seven laser diodes (in the range of 750-1100 nm) with energy outputs of around hundred milliwatts each were combined with a fast diode array spectrometer (400-1100 nm, 1024 pixels, integration time from 3 ms) as detector. Measurements in transmission mode were performed in solutions of sugars in aqueous solutions and in deuteriumoxide. The feasibility of non-destructive measurements in transmission mode was investigated for different fruits and vegetables.

  • PDF

The design and Manufacture of Laser Induced Fluorescence Spectroscope Using the High Resolution Charge Coupled Device (고정밀 전하결합장치를 이용한 레이저유도 형광분광기의 설계 및 제작)

  • Kim, Ki-Jun;Lee, Hoo-Seol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.2
    • /
    • pp.129-133
    • /
    • 2005
  • It is very important to use the charge coupled devices (CCDs) in spectrometry because we can study the molecular energy level, molecular structure, absorption or emission, intermolecular reaction, weakly bound molecular energy, photochemistry, fluorescence and photodynamic therapy (PDT). CCD is very essential to study the molecular structure and medical engineering combining laser spectroscopy in the modem physicsal and chemistry. Therefore, this study has designed and manufactured the electromagnetic spectrometry with CCD and then analyzed the printed electronic circuit. In the yesterday, CCD was thought to be used in only broadcasting system. But nowadays, it is used by industrial demand in observations, instrumentations and robotics as the industry develop.

  • PDF

Effect of Various Supports on the Physico-chemical Properties of V-Sb Oxides in the Oxidative Dehydrogenation of Isobutane

  • Shamilov, N.T.;Vislovskiy, V.P.
    • Journal of the Korean Chemical Society
    • /
    • v.55 no.5
    • /
    • pp.812-818
    • /
    • 2011
  • [ $V_{0.9}Sb_{0.1}O_x$ ]systems, bulk and deposited on different supports (five types of ${\gamma}$-aluminas, ${\alpha}$-alumina, silica-alumina, silica gel, magnesium oxide), have been tested in the oxidative dehydrogenation (ODH) of iso-butane. This statement is derived from the data obtained by a set of characterisation techniques(specific surface area measurements, X-ray diffraction, X-ray photoelectron spectroscopy, laser Raman spectroscopy, in situ differential scanning calorimetry and in situ diffuse reflectance-absorption infrared Fourier transform spectroscopy).

The Effect of Tail State on the Electrical and the Optical Properties in Amorphous IGZO (비정질 InGaZnO4 박막의 전기적, 광학적 특성간의 상관관계 연구)

  • Bae, Sung-Hwan;Yoo, Il-Hwan;Kang, Suk-Ill;Park, Chan
    • Journal of the Korean Ceramic Society
    • /
    • v.47 no.4
    • /
    • pp.329-332
    • /
    • 2010
  • In order to investigate the effect of tail state on the electrical and the optical properties in amorphous IGZO(a-IGZO), a-IGZO films were deposited at room temperature on fused silica substrats using pulsed laser deposition method. The laser pulse energy was used as the processing parameter. In-situ post annealing was carried out at $150^{\circ}C$ right after the film deposition. The $O_2$ partial pressure during the deposition and the post annealing was fixed to 10mTorr. The carrier mobility of the a-IGZO films had a range from 2 to $18\;cm^2/Vs$ at carrier concentrations greater than $10^{18}\;cm^{-3}$. As the laser energy density increased, the Hall mobility increased. And post annealing improved the Hall mobility, as well. The optical property was examined using the ultraviolet-visible spectroscopy. The a-IGZO films that have low Hall mobility exhibited stronger and broader absorption tails in >3.0 eV region. Post annealing reduced the intensity of the tail-like absorption. The absorption tail in a-IGZO films is an important factor which affects the electrical and the optical properties.

Measurement of Spatiotemporal Distribution for the Density of Excited Xe Atoms in the 1s5 in Accordance with Various ITO-shapes in Ac-PDP (교류형 플라즈마 평판 표시장치(AC-PDP)에서 ITO 전극 구조에 따른 Xe 여기종의 시공간 밀도 분포 연구)

  • Cho, S.H.;Hong, Y.J.;Son, C.G.;Han, Y.G.;Jeong, Y.H.;Gwon, G.C.;Hong, B.H.;Cho, G.S.;Choi, E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.1
    • /
    • pp.54-59
    • /
    • 2009
  • We have measured the spatiotemporal behavior for the density of excited Xe atoms in the $1s_5$ metastable states by laser absorption spectroscopy in accordance with various shapes of ITO electrode. The maximum density of excited Xe atoms in the Is5 state in a discharge cell for fish-boned, T-shaped and squared ITO electrodes has been measured to be $3.01{\times}10^{13}\;cm^{-3}$, $2.66{\times}10^{13}\;cm^{-3}$ and $2.06{\times}10^{13}\;cm^{-3}$, respectively. Throughout this experiment, we could understand the influence of the shapes of ITO electrode of micro discharge cell on the high efficiency of AC-PDPs.

Spectroscopic Study of the Ã1A" - X~1A' System of CHBr

  • Shin, Seung-Keun;Park, Seung-Min
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.3
    • /
    • pp.905-908
    • /
    • 2011
  • We report fluorescence excitation and emission spectra of the CHBr molecule generated via pyrolysis of $CH_3Br$ in a molecular beam experiment. The 193 nm attenuation cross sections were estimated from the reduction of the CHBr signal as a function of the excimer laser fluence. The derived 193 nm absorption cross section for CHBr [$(3.24{\pm}0.59){\times}10^{-17}\;cm^2$] is slightly higher than the absorption cross section previously determined for CHCl [$(2.6{\pm}0.8){\times}10^{-17}\;cm^2$], but the difference is within the estimated uncertainties in the measured cross section.

Experimental study on TDLAS temperature profile measurement using temperature binning method (TDLAS에서 temperature binning 방법을 이용한 온도 측정에 대한 실험적 연구)

  • Yoon, Sungwoon;Kim, Sewon;Shin, Myungchul;Lee, Changyeop
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.27-28
    • /
    • 2012
  • Tunable diode laser absorption spectroscopy(TDLAS) measurement techniques for several gases densities and temperatures have been applied in industrial combustion systems. Accurate measurement of temperature profile is very important, especially in power plants and heating furnaces. So profile fitting and temperature binning methods are new issue for accurate measurement of temperature in laser gas sensing. Temperature binning method is applied in this study for the measurement of temperature profile using tube furnace with three temperature zones. In this study the temperature profiles of tube furnace is accurately measured within 5% error, and this technique is proved to be very promising in the field of temperature profile measurement.

  • PDF

The Effects of Post-annealing on Laser CVD SiON Films (Laser CVD SiON막의 막 형성 후 열처리 의존성)

  • Kim, C.D.;Kim, I.S.;Koh, J.H.;Lee, S.K.;Sung, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.336-338
    • /
    • 1997
  • The anneal behavior of ArF excimer Laser CVD SiON films has been studied using FT-IR absorption spectroscopy. The anneal temperature range was $400{\sim}800^{\circ}C$ Abundant hydrogen effusion from thes layers was observed as anneal temperature increased. The coexistence of both Si-H am N-H bonds offers the possibility for cross linking am evidence for the occurrence of cross lingking was found in the IR spectrum. The electrical properties were also obtained that tire films have low leakage currents am good TZDB properties.

  • PDF