• Title/Summary/Keyword: Laser Vibration Measurement

Search Result 130, Processing Time 0.031 seconds

A Continuous Scanning Laser Doppler Vibrometer for Mode Shape Analysis (모드형상분석을 위한 연속 스캐닝 레이저 도플러 진동측정기)

  • Park, Kyi-Hwan;Choi, Ji-Eun;La, Jong-Pil;Wang, Sem-Yung;Kyoung, Yong-Soo;Kim, Koung-Suk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.5
    • /
    • pp.734-741
    • /
    • 2003
  • This paper addresses the vibration mode shape Measurement technique utilizing a Continuous Scanning Laser Doppler Vibrometer (CSLDV). The continuous scanning capability is added to the conventional discrete Laser Doppler Vibrometer by reflecting the laser beams on the surface of the object using two oscillating mirrors. The bow scanning resulted from the proposed scanning method is eliminated by feedback control. The velocity output signal from the CSLDV is modulated to give the spatial velocity distribution in terms of coefficients which are obtained from the Fast Fourier Transformation of the time dependent velocity signal. Using the Chebyshev series from, the analysis of the vibration mode shape techniques for straight line scanning and 2 dimensional scanning are presented and discussed. The performance of the proposed SLDV is presented using the experimental results of the vibration mode shape of a cantilever and plate

A Study on a Laser Scanning Vibrometer Using a Magnetostrictive Resonant Device (자기 변형 공진 기구를 이용한 레이저 스캐닝 진동측정기에 관한 연구)

  • 이정화;류제길;박기환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.11
    • /
    • pp.58-66
    • /
    • 1998
  • A low power consuming laser scanning vibrometer is studied for its development. For its optical system, a laser interferometer is constructed to use the Doppler effect. In order to reduce the driving power of the scanning system, a small displacement of the scanning system is produced, which is achieved by using a magnetostrictive actuator. A sufficient rotating angle of the scanning system is obtained by using an amplified displacement from the resonant phenomena of a second order mechanical system composed of a mass and spring. The control of the magnetostrictive actuator using a Terfenol-D is performed without using a feedback system to help reduce the power consumption. The vibration analysis is made for the sinusoidal scanning input to have the space domain information from the time domain of the velocity of a vibration object. As a partial work of development of a tow power consuming laser scanning vibrometer, in this work, a scanning system which has the above features is developed and experimentally investigated. For the purpose of the optical system calibration, the vibration measurement for one axis is presented and the future works are discussed.

  • PDF

Optical technique of precision measurement using Electronic Speckle Pattern Interferometry (ESPI를 이용한 광학식 정밀 계측 기술)

  • 은재정;정영환;최평석;박해수
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.4
    • /
    • pp.40-46
    • /
    • 2003
  • In this research, we accomplished the interpreting about the vibration of the object, which is the out of plane displacement in the Electronic Speckle Pattern Interferometry(ESPI), one of the optical measuring technique. The vibrating object has a inherent nodal line, therefore we can get the information about the vibration of the object by interpreting it. we used a speaker and a cantilever plate for a measurement object, and interpreted it qualitatively by using the Time-Average ESPI. In this experimental result, the speaker has the lower mode of fringe at 550Hz, 570mV, and the higher mode of fringe at 950Hz, 570mV This ESPI is a non-destructive test, and because of using the laser at measuring, it has a high resolution. The ESPI can test vibration mode regardless of the test object size, because the area which illuminated laser is the test area.

  • PDF

Error Evaluation on Flame Measurement in Combustion Field (연소장내 화염계측 오차 평가)

  • Yang, Young Joon;Heo, Tae Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.167-169
    • /
    • 2014
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, Phase Doppler Anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

  • PDF

Linewidth Reduction of a Yellow Laser by a Super-cavity and the Measurement of the Cavity Finesse (초공진기를 이용한 노란색 레이저의 선폭 축소 및 초공진기의 예리도 측정)

  • Lee, Won-Kyu;Park, Chang-Yong;Park, Sang-Eon;Ryu, Han-Young;Yu, Dai-Hyuk;Mun, Jong-Chul;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.3
    • /
    • pp.123-128
    • /
    • 2010
  • Sum frequency generation was utilized to obtain a yellow laser with the wavelength of 578.4 nm for a probe laser of an Yb lattice clock. The output of an Nd:YAG laser with wavelength of 1319 nm and that of an Yb-fiber laser with wavelength of 1030 nm were passed through a waveguided periodically-poled lithium niobate (WG-PPLN) for sum frequency generation. It is required that the probe laser has a linewidth of the order of 1 Hz to fully resolve the Yb lattice clock transition. Thus, the linewidth of the probe laser was reduced by stabilizing the frequency to a super-cavity. This was made of ULE with a low thermal expansion coefficient, and was mounted on an active vibration-isolation table at the optimal point for the reduced sensitivity to vibration. Also, this was installed in a vacuum chamber, and the temperature was stabilized to 1 mK level. This system was installed in an acoustic enclosure to block acoustic noise. The finesse of the super-cavity was measured to be 380 000 from the photon life time of the cavity.

3 Dimensional Vibration Measurement of Structures Using GPS Carrier Phase (GPS 반송파를 이용한 구조물의 3차원 진동측정)

  • Suh, Dae-Wan;Lee, Young-Jae;Park, Hoon-Cheol;Yoon, Kwang-Joon;Jee, Gyu-In;Park, Chan-Gook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1303-1310
    • /
    • 2000
  • GPS carrier phase is supposed to provide the tool for the most precise 3 dimensional positioning information. The FAST, an OTF technique, has been developed by the GPS System Laboratory of Konkuk University, and has been shown several millimeter level accuracy in root-mean-square sense. This OTF's high precision positioning capability provides an adequate tool of low frequency vibration monitoring of large structures. In this paper, the possibility of vibration measurement of a cantilever beam using FAST has been tested, which is supposed to be extended to more practical applications. The results of the experiment have been compared with those by a strain gage and laser sensor.

  • PDF

Comparison of Torsional Vibration Measurement Techniques

  • Verrecas, B.;Janssens, K.;Britte, L.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.441-441
    • /
    • 2012
  • Noise and vibration performance plays an important role in the development of rotating components, such as engines, drivelines, transmission systems, compressors and pumps. The presence of torsional vibrations and other specific phenomena require the dynamic behaviour of systems and components to be designed accurately in order to avoid comfort and durability related problems. This paper provides an overview of the instrumentation and challenges related to torsional vibration testing. The accuracy and performance of five measurement techniques (high-speed incremental encoder, dual beam laser interferometer, zebra tape, zebra disc, direct pulse measurements with magnetic probe) is investigated by measurements on a Fiat Punto 1.4 liter engine. The potential sources of error are discussed to explain the inaccuracies of each technique.

  • PDF

Research about ESPI System Algorithm Development that Use Modulating Laser (Modulating Laser를 이용한 ESPI System algorithm 개발에 관한 연구)

  • Kim, Seong-Jong;Kang, Young-June;Park, Nak-Kyu;Lee, Dong-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.7
    • /
    • pp.65-72
    • /
    • 2009
  • Laser interferometry is widely used as a measuring system in many fields because of its high resolution and its ability to measure a broad area in real-time all at once. In conventional laser interferometry, for example out-of-plane ESPI (Electronic Speckle Pattern Interferometry), in plane ESPI, shearography and holography, it uses PZT or other components as a phase shift instrumentation to extract 3-D deformation data, vibration mode and others. However, in most cases PZT has some disadvantages, which include nonlinear errors and limited time of use. In the present study, a new type of laser interferometry using a laser diode is proposed. Using Laser Diode Sinusoidal Phase Modulating (LD-SPM) interferometry, the phase modulation can be directly modulated by controlling the laser diode injection current thereby eliminating the need for PZT and its components. This makes the interferometry more compact. This paper reports on a new approach to the LD (Laser Diode) Modulating interferometry that involves four-frame phase shift method. This study proposes a four-frame phase mapping algorithm, which was developed to have a guaranteed application, to stabilize the system in the field and to be a user-friendly GUI. In this paper, the theory for LD wavelength modulation and sinusoidal phase modulation of LD modulating interferometry is shown. Using modulating laser and research of measurement algorithm does comparison with existent ESPI measurement algorithm. Algorithm measures using GPIB communication through most LabVIEW 8.2. GPIB communication does alteration through PC. Transformation of measurement object measures through modulating laser algorithm that develops. Comparison of algorithm of modulating laser developed newly with existent PZT algorithm compares transformation price through 3-D. Comparison of 4-frame phase mapping, unwrapping, 3-D is then introduced.

Measurement of two-dimensional vibration and calibration using the low-cost machine vision camera (저가의 머신 비전 카메라를 이용한 2차원 진동의 측정 및 교정)

  • Kim, Seo Woo;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.2
    • /
    • pp.99-109
    • /
    • 2018
  • The precision of the vibration-sensors, contact or non-contact types, is usually satisfactory for the practical measurement applications, but a sensor is confined to the measurement of a point or a direction. Although the precision and frequency span of the low-cost camera are inferior to these sensors, it has the merits in the cost and in the capability of simultaneous measurement of a large vibrating area. Furthermore, a camera can measure multi-degrees-of-freedom of a vibrating object simultaneously. In this study, the calibration method and the dynamic characteristics of the low-cost machine vision camera as a sensor are studied with a demonstrating example of the two-dimensional vibration of a cantilever beam. The planar image of the camera shot reveals two rectilinear and one rotational motion. The rectilinear vibration motion of a single point is first measured using a camera and the camera is experimentally calibrated by calculating error referencing the LDV (Laser Doppler Vibrometer) measurement. Then, by measuring the motion of multiple points at once, the rotational vibration motion and the whole vibration motion of the cantilever beam are measured. The whole vibration motion of the cantilever beam is analyzed both in time and frequency domain.

An Experimental Evaluation on Vibration Serviceability of Existing Bridge by Non-contact Vibration Measurement Method (비부착식 진동측정방법에 의한 공용중 교량의 진동사용성에 대한 실험적 평가)

  • Shin, Hyun-Seop;Park, Ki-Tae;Lee, Kyu-Wan;Jun, Jin-Taek
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.6
    • /
    • pp.254-262
    • /
    • 2010
  • In order to evaluate vibration serviceability by means of non-contact vibration meter, serviceability of existing bridge were experimentally evaluated by using laser vibration meter. Test results were analyzed and compared with evaluation results acquired by using accelerometer and LVDT. To testify accuracy of laser vibration meter measured natural frequency were compared with that acquired by using accelerometer. According to test and comparison results it is showed that serviceability can be evaluated properly enough from the tolerance curve of Reiher-Meister for the estimated acceleration that can be calculated by the numerical differentiation of measured velocity. But because of cumulative numerical error occurred during integration of measured velocity in the time domain serviceability grade could be different from the result acquired by LVDT.