• 제목/요약/키워드: Laser Power supply

검색결과 106건 처리시간 0.031초

IGBT를 사용한 금속증기레이저용 펄스 전원 (A Pulse Power Supply for a Metal Vapor Laser Using IGBTs)

  • 진정태;차병헌;김철중;이흥호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권8호
    • /
    • pp.415-419
    • /
    • 2004
  • A pulse power supply using IGBTs and MPC (magnetic pulse compression) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a vacuum tube or thyratron type pulse power supply. A series-connected IGBT array generated a long pulse of its pulse width 2 ${\mu}\textrm{s}$ md then it was compressed to less than 100 ns by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 10 mm inner diameter and 0.5 m discharge length. and successfully operated.

정밀 용접용 펄스형 Nd:YAG 레이저 가공기 개발 (Development of a pulsed Nd:YAG laser materials processing system)

  • 김덕현;정진만;김철중;이종민
    • Journal of Welding and Joining
    • /
    • 제9권1호
    • /
    • pp.32-39
    • /
    • 1991
  • A 200W pulsed Nd: YAG laser for fine welding was developed. The important laser parameters such as laser peak power, average power, pulse width, and pulse energy for welding were studied. In order to obtain the sufficient laser power density for welding, thermal lensing effects were analyzed and a laser resonator with laser beam divergence was designed. The power supply unit was designed to support up to 7kW input. The pulse control unit was developed using a GTO thyristor and could control over 100kW input power to obtain 3.5kW peak power laser. Also due to the GTO thyristor the pulse width could be varied continuously from 0.1 to 20 msec and maximum repetition rate was as high as 300pps.

  • PDF

금속 증기 레이저용 펄스 전원 장치 (A Pulse Power Supply for Metal Vapor Lasers)

  • 차병헌;이흥호;진정태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권5호
    • /
    • pp.190-197
    • /
    • 2005
  • A reliable and compact pulse power supply using a thyratron and a magnetic pulse compression (MPC) circuit was developed for a metal vapor laser. The life time of the pulse power supply is expected to be much longer than that of a conventional thyratron-discharge type pulse power supply. A thyratron generated a long pulse of its conduction pulse width 500 ns and then it was compressed to less than 80 ns of its output voltage rise time by a three stage MPC circuit. This pulse power supply was applied to a laser plasma tube of 30 mm inner diameter and 1.5 m discharge length. It was operated several hundreds hours without any troubles.

A Study on the Adjusting Output Energy of the $CO_2$ Laser Controlled Directly in AC Power Line

  • Noh, Ki-Kyong;Jeong, Jong-Jin;Chung, Hyun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권4호
    • /
    • pp.152-154
    • /
    • 2005
  • We demonstrate a simple $CO_2$ laser by controlling firing angle of a TRIAC switch in ac power line. The power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply does not need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. In order to control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of TRIAC gate is varied from $45^{circ}$ to $135^{circ}$. A ZCS(Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control the gate signal of the TRIAC precisely. The maximum laser output of 40W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60Hz, and a TRAIC gate firing angle of $90^{circ}$.

ZCS공진형 컨버터를 적용한 고반복 대출력 펄스형 Nd:YAG 레이저 전원장치 개발 (Development of high repetition rate and high power pulsed Nd:YAG laser power supply using ZCS resonant converter)

  • 조기연;김은수;변영복;김희제;박점문;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.514-517
    • /
    • 1996
  • Zero current switching(ZCS) series resonant converter is used to control laser power density in a pulsed Nd:YAG laser power supply. The high power and high repetition rate paused Nd:YAG laser is designed and fabricated to control current pulse width and pulse repetition rate in the double elliptical laser oscillator. In order to find out operational characteristics of pulsed Nd:YAG laser, the electrical properties of driving power supply and laser output power are investigated and experimented by changing of the current pulse width from 200uS to 350uS(step 50uS) and pulse repetition rate range of 500pps(pulse per second) to 1150pps. From that result, we obtaind maximum efficiency of 1.83% and maximum laser output or 220W at the condition of 350 uS and 1150pps with one Nd:YAG rod), and obtained that of more than 400W with two laser head connecting series.

  • PDF

치과 및 교부과용 30W급 Er:YAG 레이저 설계 및 구현 (A Design and Implementation of 30w class Er:YAG laser adopted skin and dental clinic.)

  • 김휘영;신경애
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.211-214
    • /
    • 2001
  • For general laser power supply, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is connected to a switching element in the secondary of the transformer. So the Dower supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition, charged energy of energy-storage capacitor is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this raper, to improve laser efficiency, we designed and fabricated the power supply in which the SCR was turned on in zero point by the methods of ZCC(zero crossing control), PFN(pulse forming network) in result, laser output efficiency increased by hte 4% other than conventional supply, when a repetition rate was increased by the 10[pps], In 20(pps), efficiency was increased by about 8%

  • PDF

무선 광 전송용 APD 전력 공급기와 원통형 레이저형상 보정용 마이크로 렌즈 기술 (The Improved Power Supply for APD and Efficiently Designed Cylindric Micro-lens for a Wireless Optical Transmission System)

  • 김만호
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권11호
    • /
    • pp.654-659
    • /
    • 2005
  • An improved power supply for APD(Avalanche Photo Diode) with a received optical power monitoring circuit allows the received optical power increase temporary without of the degradation of the electrical signal. For the cost reduction and simple fabrication, an improved power supply has been proposed that it was designed for driving a APD as a receiving device of a wireless optical transmission system. It was demonstrated that it was possible to improve a dynamic range by compensating the temperature coefficient of the APD up to 1.0 V/$^{\circ}C$ through the power supply. Also, for an efficient transmission at the receiver end, a simple structure of a single cylindrical micro-lens configuration was used in conjunction with the laser diode to partially compensate a laser beam ellipticity. For this purpose, an astigmatism introduced by the micro-lens is utilized for the additional compensation of the beam ellipticity at the receiver end. In this paper, it is demonstrated that an efficient beam shaping is realized by using the proposed configuration consisting of the single lens attached to the laser diode.

3단 병렬 충.방전 방식을 적용한 고반복 펄스형 Nd:YAG 레이저 출력거울 반사율의 최적화 (The optimization of output coupler reflectivity of high repetitive pulsed Nd:YAG laser system adopted 3-mesh parallel sequential charge and discharge method)

  • 김휘영;홍수열;김동수
    • 한국컴퓨터산업학회논문지
    • /
    • 제2권3호
    • /
    • pp.369-376
    • /
    • 2001
  • 펄스형 YAG 레이저 시스템의 효율개선을 위해서는 공진기 및 레이저 전원장치의 최적화가 필수적이다. 따라서, 본 연구에서는 공진기 출력거울의 반사율 최적화 및 기존의 전원보다 훨씬 컴팩하고, 경제적이며 가공목적에 따라 출력을 정밀하게 제어할 수 있는 새로운 방식의 레이저시스템을 설계 및 제작하였다. 그 결과 50[W]급의 펄스형 Nd:YAG 레이저 시스템에서는 출력거울의 반사율이 85%일 때 최대 출력을 나타내었다. 그리고 3단 병렬 충ㆍ방전 방식의 전원시스템은 3개의 콘덴서가 순차적으로 충ㆍ방전함으로서 1개의 콘덴가 충ㆍ방전하는 방식보다 더 많은 에너지를 플래쉬램프에 전달할 수 있어 더 높은 출력을 얻을 수가 있었다. 실험을 통해 제시한 방법의 타당성을 검증하였다.

  • PDF

A Design and Implement of the Medical Nd:YAG Laser Firmware under in ZCC method

  • Kim, Whi-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.40.3-40
    • /
    • 2001
  • The pulsed Nd:YAG laser is the most commonly used type of solid-state laser in many fields. In material processing and medical treatment, the power density control of a laser beam Considered to be significant, which depends on the flashlamp current pulse width and pulse repetition rate. For general laser power supply to control the laser power density, the secondary of the power transformer is connected to the rectifier and filter capacitor. The output of a rectifier is applied to a switching element in the secondary of the transformer. So power supply is complicated and the loss of switching is considerably. In addition, according to increasing pulse repetition rate, charged energy of energy-storage capacitor bank is not transferred sufficiently to flashlamp, and laser output efficiency decreases. In this study, we have ...

  • PDF

수술용 2파장 펄스형 Nd:YAG 레이저 개발 (Development of Surgical Two-wavelegth Nd:YAG Laser)

  • 윤길원;김홍식
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF