• 제목/요약/키워드: Laser Head

검색결과 301건 처리시간 0.025초

항온 Laser MCT(LAM) 복합 가공의 최적 가공 조건 해석 (A Study on the Analysis of Optimal Working Condition for Constant Temperature Laser MCT(LAM) Combined Machining)

  • 박정호;김귀남
    • 한국산업융합학회 논문집
    • /
    • 제26권6_3호
    • /
    • pp.1197-1204
    • /
    • 2023
  • Ti-alloy, a high-strength alloy material among the materials used in aircraft that are trending toward lighter weight, is classified as a difficult-to-cut material that requires a lot of energy for cutting. Cutting in a high-temperature environment is considered one means of making this possible, and various studies have been conducted on it. In particular, research on LAM (Laser Assisted Machining (LAM)), which utilizes laser heating of the cutting area, is being actively conducted. Before processing of the milling cutter begins, the temperature is raised locally by the laser irradiated through the laser head carrier, and the resistance during milling is reduced. Therefore, in this paper, in order to derive such conditions, we performed heat transfer analysis according to transfer conditions and compared it with actually applied test data to use it to establish appropriate processing conditions.

연축성 발성장애 환자에서 레이저와 단극성 전기소작기를 이용한 갑상피열근신경 절제술 1예 (A Case of Thyroarytenoid Myoneurectomy Using LASER and Monopolar Electrical Device in Spasmodic Dysphonia)

  • 이소정;정수연;정성민;김한수
    • 대한후두음성언어의학회지
    • /
    • 제30권2호
    • /
    • pp.132-135
    • /
    • 2019
  • Spasmodic dysphonia is a focal laryngeal dystonia that results in involuntary spasms during speech. The etiology of spasmodic dysphonia is not yet defined, but it is presumed to be a neurological abnormality of central nervous system motor function. The treatment of choice for spasmodic dysphonia is botulinum toxin injection directly at the laryngeal muscles. However botulinum toxin injection requires repeated procedures. Many different kinds of surgical treatments have been introduced but the recurrence rate is still high. So we performed myomectomy with LASER and neurectomy with specially designed electrical surgical knife which can cut recurrent laryngeal nerve branch selectively with its noble curved section. We report a case of a 43-year-old male patient with spasmodic dysphonia treated by thyroarytenoid myoneurectomy.

두경부 영역에서의 로봇 수술 (Robotic Surgery in Head and Neck)

  • 태경;신광수
    • 대한기관식도과학회지
    • /
    • 제16권1호
    • /
    • pp.27-32
    • /
    • 2010
  • Organ preservation surgery and minimally invasive surgery have been developed during the past 20 years with major focus on transoral laser surgery, endoscopic surgery, and robotic surgery. Two major robotic surgeries in head and neck area are transoral robotic surgery (TORS) and robotic thyroidectomy. Transoral robotic surgery is a safe and efficacious method of surgical treatment of oropharyngeal. hypopharyngeal and laryngeal neoplasm. Advantages of the technique include adequate ability to visualize and manipulate lesions with two hands. TORS can provide magnified three dimensional views and overcome the limitation resulting from the "line of sight" which hinders transoral laser procedure. The swallowing function following transoral robotic surgery show superior and patients were able to retain or rapidly regain swallowing function in the majority of cases. Recently, robotic thyroidectomy has also been developed to overcome the [imitation of endoscopic thyroidectomy. Robotic thyroidectomy by a gasless unilateral axillo-breast or axillary approach using a da Vinci S Surgical Robot is a feasible and cosmetically excellent procedure. It can be a promising alternative to endoscopic thyroidectomy or conventional open thyroidectomy.

  • PDF

평면연삭시 복합검출방법에 의한 숫돌마멸 예측 (Prediction of Wheel Wear when Surface Grinding by Dual Detection Methods)

  • 왕덕현
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.172-177
    • /
    • 1998
  • An experimental study on the prediction of grinding wheel wear by dual detection methods was conducted by the laser displacement and acoustic emission(AE) system. The laser displacement sensor was located above the head of the grinding wheel and the AE sensor was set under the workpiece, where the wheel were condition can be detected. It was found that the dual detection methods by laser displacement system and AE system made it possible to predict the wheel wear. From the experiments, the root mean square(RMS) values both methods was found to be proportional to the grinding wheel wear.

  • PDF

레이저 하이브리드 용접과 레이저 브레이징 -최신 기술 및 Audi A8과 VW-Phaeton의 실제 적용 사례- (Laser Hybrid Welding and Laser Brazing -State of the Art and Applications in Audi A8 and VW-Phaeton-)

  • 김유찬;김종도
    • Journal of Welding and Joining
    • /
    • 제22권2호
    • /
    • pp.13-18
    • /
    • 2004
  • 레이저 빔과 아크를 하나의 용접 프로세스로 병합하는 기술에 관해서는 이미 70년대부터 알려져 왔으나 별다른 개발로 이어지지 못하다가 최근에서야 다시 눈을 돌리게 되었다. 이 기술의 핵심 과제는 아크의 장점과 레이저의 장점을 어떻게 단일 혼합 프로세스로 조합하느냐 하는 것이다.(중략)

방사선치료 시 C-Rad system을 이용한 셋업의 평가 (Evaluation of Setup When Using C-Rad System in Radiotherapy)

  • 박은태;고성진;최석윤;김정훈;김창수;김동현;강세식
    • 한국콘텐츠학회논문지
    • /
    • 제12권5호
    • /
    • pp.303-310
    • /
    • 2012
  • 방사선 치료에 있어서 정확한 환자 포지셔닝과 셋업은 치료의 성패를 좌우할 수 있는 중요한 인자이다. 기존의 방사선 치료실내에 장착된 3-laser system을 이용한 셋업에서, 최근에는 체표면 윤곽 스캐닝 시스템(C-Rad system)의 사용이 시도되고 있다. 체표면 윤곽 스캐닝 시스템의 유용성을 평가하기 위하여 C-Rad system과 3-laser system을 이용한 셋업 오차의 정확도를 비교, 평가함으로써 임상에서의 유용성을 확인하고자 하였다. 인체부위는 내부적인 움직임이 없고, 고정용구의 적용이 간편한 두경부로 한정하였으며, Alderson Rando anthropomorphic phantom과 두경부에 병변이 있는 방사선 치료 환자 10명을 대상으로 하였다. Phantom을 대상으로 한 C-RAD system의 셋업 에러 평균과 표준편차는 X축 $0.55{\pm}0.51mm$, Y축 $-0.2{\pm}0.523mm$, Z축 $-0.85{\pm}0.587mm$로 나타났으며, 환자를 대상으로 한 실험에서는 X축 $-0.05{\pm}0.621mm$, Y축 $0.075{\pm}0.755mm$, Z축 $-1.025{\pm}0.617mm$로 산출되어, 전반적으로 3-laser system에 비해 셋업의 정확도가 우수하였으나, Z축의 에러 발생률은 C-RAD system이 약간 높게 나타났다. 체표면 윤곽 스캐닝 시스템은 두경부의 방사선 치료 시에 정확한 포지셔닝을 유도함으로써 셋업오차를 최소화 시키는데 기여할 것으로 사료된다.F

레이저 심 용입 용저에서 3차원 열유동 해석에 관한 연구 (A Study on the Three-Dimensional Heat Flow Analysis in the Laser Welding for Deep Penetration)

  • 이규태;김재웅
    • Journal of Welding and Joining
    • /
    • 제18권3호
    • /
    • pp.76-82
    • /
    • 2000
  • In this study, three-dimensional heat flow in laser beam welding for deep penetration was analyzed by using F.E.M common code, and then the results were compared with the experimental data. The models for analysis are full penetration welds and are made at three different laser powers (6, 9.9, 4.5 kW) with two different welding speeds (5.8mm/s, 5mm/s). The characteristics of thermal absorption by the workpiece during deep penetration laser welding can be represented by a combination of line heat source through the workpiece and distributed heat source at the top surface due to the plasma plume above the top surface. This gives an insight into the way in which the beam interacts with the material being welded. The analyses performed with the combined heat source models show comparatively good agreement between the experimental and calculated melt temperature isotherm, i.e, the fusion zone boundary. The results are used to explain the "nail head" appearance of fusion zone, which is quite common in laser beam welds.eam welds.

  • PDF

2축 이송계 정밀도 측정을 위한 레이저 간섭계 4축 자동정렬장치 개발 (Development of a 4-axis Auto-aligning System for Precision Measurement of 2-axis Feeding Systems Using Laser Interferometer)

  • 김현수;홍성욱
    • 한국정밀공학회지
    • /
    • 제17권9호
    • /
    • pp.75-80
    • /
    • 2000
  • Although laser interferometer is widely accepted as a tool for measurement of motion accuracy the set-up procedure is time-consuming because of the strict requirement on alignment between laser head and optic units. This paper presents a 4-axis auto-aligning system which is useful for easy set-up of laser interferometer so as to evaluate precision of a 2-axis feeding system. This paper proposes two ideas for alignment in laser interferometer set-up: one is use of mirror and retroreflectors. and the other is taking advantage of the pre-defined movement and peculiar characteristic of retroreflecotrs. The pros and cons of the two methods are discussed. Illustrative experimental results are presented in which the developed system is applied to a XY table.

  • PDF