• Title/Summary/Keyword: Laser Head

Search Result 301, Processing Time 0.03 seconds

A Case of Bilateral Vocal Fold Paralysis from Acromegaly (말단 비대증 환자에서 발생한 양측성대마비 1예)

  • Park, Min-Woo;An, Soo-Youn;Roh, Dong-Hwan;Kwon, Tack-Kyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.20 no.1
    • /
    • pp.68-70
    • /
    • 2009
  • Acromegalic patients can develop mild upper airway obstruction. However, the limitation of both vocal folds mobility developing dyspnea is rare. We report a case with bilateral vocal cord paralysis associated with acromegaly. The patient visited our clinic presenting dyspnea showing bilateral vocal cord hypomobility in laryngoscopy. The patient underwent a tracheostomy and a transsphenoidal resection of the pituitary adenoma. Thereafter, laser cordotomy with medial arytenoidectomy was done for the permanent treatment of glottal obstruction. The tracheotomy canula was successfully removed one month after the surgery.

  • PDF

Intractable Muscle Tension Dysphonia Treated by Injection Laryngoplasty and Lidocaine Injection (성대 주입술과 리도카인 주입술을 통해 치료한 난치성 근긴장성 발성장애)

  • An, You Young;Jeong, Jun Yeong;Park, Ki Nam;Lee, Seung Won
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.32 no.2
    • /
    • pp.94-97
    • /
    • 2021
  • Muscle tension dysphonia (MTD) is a voice disorder characterized by excessive tension of the laryngeal muscles during phonation. Voice therapy is the gold standard of treatment for MTD. However, patients with MTD do not always respond to voice therapy. Multidisciplinary approaches have been attempted to treat intractable MTD such as lidocaine instillation, lidocaine injection to recurrent laryngeal nerve, botox injection and excision of false ventricle using CO2 laser. Recently, injection laryngoplasty is suggested that assists in more efficient phonation and voice therapy to MTD patients. A patient with intractable MTD underwent lidocaine injection and injection laryngoplasty showed improved voice quality and remained stable until postoperative 3 months without any complications.

Removal of a Bronchial Foreign Body by Bronchoscopic Cryotherapy: A Case Study

  • Kim, Hyoyeon;Byun, Gwanghyun;Lee, Sang Joon;Woo, Seung Hoon
    • Medical Lasers
    • /
    • v.10 no.1
    • /
    • pp.55-59
    • /
    • 2021
  • A foreign body in the airway can be a potentially life-threatening event. The diagnosis and treatment of foreign bodies in the airway are a challenge for otolaryngologists. Despite the improvements in medical care and public awareness, approximately 3,000 deaths occur each year from foreign body aspiration. A high degree of vigilance is required to ensure prompt treatment and avoid the complications of foreign body aspiration. The author encountered a case of a 77-year-old female patient who had aspirated an unknown foreign body that was fixed in her main bronchus. An initial attempt was made to remove it with a flexible bronchoscope but failed due to the patient's hypoxemic state during the procedure. Under general anesthesia, a rigid bronchoscopic examination was performed, but it was difficult to approach the object due to the bronchus curvature. Instead, a cryotherapy instrument of bronchoscopy was applied. The foreign body was frozen and removed to the carina, where a laryngoscope and laryngeal forceps were used to remove it.

A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER (아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구)

  • Ju, Sang-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF

Analysis of Homogenized Laser Beam Display by a Polymeric Stretchable Diffuser (스트레쳐블 폴리머 디퓨저를 이용한 균질 레이저 디스플레이 해석)

  • Lee, Jae-Won;Lee, Seon-Bong;Choi, Hae-Woon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • A stretchable polymeric membrane shaped diffuser was used to homogenize the coherent laser beam. The developed RGB module was used to focus and defocus test by beam combiners. Average oscillation frequency was set at 180Hz~300Hz and it resulted in the best homogenization effect in visual range. The blue laser module turned out to be the worst case for the transmission and primary reason is believed to be the short length of irradiated laser beam. The developed system removed the speckling and the brightness was decreased by 10 ~ 20% for the RGB laser. Overall the brightness was decreased by 13% and homogenity with respect to the temporal axis was improved from 30fs to 110fs.

Development of An Automated Scanning Laser Doppler Vibrometer for Measurements of In-Plane Structural Vibration (평면 구조 진동 측정을 위한 자동화된 스캐닝 레이저 도플러 진동측정기의 개발 및 연구)

  • Kil, Hyun-Gwon
    • Journal of KSNVE
    • /
    • v.7 no.2
    • /
    • pp.231-238
    • /
    • 1997
  • An automated scanning laser Doppler vibrometer (LDV) has been designed, and built to measure in-plane vibration fields over structures. Use of optical fibers allows the compact design of a laser probe head which can be scanned over the vibrating structures. An algorithm for automated self-alignment of the laser probe is developed. The system is completely automated for scanning over the structures, focusing two laser beams at each data point until the detected vibration signal is stable, and for recording and transferring the data to a system computer. The automated system allows one to get extensive data of the vibration field over the structures. The system is tested by scanning a piezoelectric cylindrical shell and a plate excited by a continuous signal and by a pulse signal, respectively. Results show that the automated scanning LDV system can be a useful tool to measure the in-plane vibration field and to detect the elastic waves propagating on the vibrating structures.

  • PDF

Development of a Grinding Robot System for the Engine Cylinder Liner's Oil Groove (실린더 라이너 오일그루브 가공 로봇 시스템 개발)

  • Noh, Tae-Yang;Lee, Yun-Sik;Jung, Chang-Wook;Oh, Yong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.6
    • /
    • pp.614-619
    • /
    • 2009
  • An engine for marine propulsion and power generation consists of several cylinder liner-piston sets. And the oil groove is on the cylinder liner inside wall for the lubrication between a piston and cylinder. The machining process of oil groove has been carried by manual work so far, because of the diversity of the shape. Recently, we developed an automatic grinding robot system for oil groove machining of engine cylinder liners. It can covers various types of oil grooves and adjust its position by itself. The grinding robot system consists of a robot, a machining tool head, sensors and a control system. The robot automatically recognizes the cylinder liner's inside configuration by using a laser displacement sensor and a vision sensor after the cylinder liner is placed on a set-up equipment.

The Study on the Fuel Vapor Distribution of Homogeneous Charge in a DISI Engine with a 6-Hole Fuel Injector (6공 연료분사기를 장착한 DISI 엔진 내 균질급기의 연료증기 분포 특성)

  • Kim, S.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.1
    • /
    • pp.5-10
    • /
    • 2011
  • The spatial fuel vapor distribution of the homogeneous charge by a 6-hole injector was examined in a optically accessed single cylinder direct injection spark ignition(DISI) engine. The effects of in-cylinder charge motion, and fuel injection pressure, and coolant temperature were investigated using a planar LIF (Laser Induced Fluorescence) technique. It was confirmed that the in-cylinder tumble flow played a little more effective role in the spatial fuel vapor distribution than the swirl flow during the compression stroke at 10 mm and 2 mm planes under cylinder head gasket and the increased fuel injection pressure activated spatial distributions of the fuel vapor. In additions, richer mixtures were concentrated around the cylinder wall by the increase of the coolant temperature.

Effect of Stroke Changes on the In-Cylinder Flow Field in a Four-Valve SI Engines (Stroke변화가 Four-Valve SI 엔진 실린더내 유동장에 미치는 영향)

  • 유성출
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.1-8
    • /
    • 2001
  • The flow field inside a cylinder of four-valve Sl engine was investigated quantitatively using a three-dimensional Laser Doppler Velocimetry system, to determine how stroke changes affect the flow field. The purpose of this work was to develop quantitative methods which correlate in-cylinder flows to engine performance. For this study, the sane intake manifold, engine head, cylinder, and the piston were used to examine the flow characteristics in different strokes. Quantification of the flow field was done by calculating three major parameters which are believed to adequately characterize in cylinder motion. These quantities were TKE, tumble and swirl ratios. The LDV results reveal that flow patterns are similar, the flow velocities scale with piston speed but another parameters such as TKE, and tumble and swirl numbers are not the same for different stroke systems.

  • PDF

In-Cylinder Fuel Behavior According to Fuel Injection Timing and Port Characteristics in an Sl Engine : Part II-With Low/Medium Swirl (가솔린 엔진에서 연료분사시기와 포트특성에 따른 실린더 내 연료거동 : Part II - 저/중 와류의 경우)

  • 엄인용;조용석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.9-17
    • /
    • 2001
  • This paper is the second of 3 companion papers which investigate axial stratification process. In-cylinder fuel behavior has been investigated in the port injected Sl engine by visualizing for the purpose of understanding stratification. Planar laser light sheet from an Nd:YAG laser has been illuminated through the transparent quartz cylinder of the single cylinder optical engine and the Mie scattered light has been captured through the quartz window in the piston head with an ICCD camera. Fuel has been replaced with an air-ethanol mixture to utilize atomized fuel spray fur the visualization purposes. This results have been compared with steady flow concentration measurement. For low/medium swirl port, the early injection makes such a fuel distribution state that is upper-rich, middle-lean and lower-rich along the combustion chamber and cylinder by tumbling motion. On the other hand, the late injection induces upper-rich, middle-lean and lower-rich state due to the short fuel penetration.

  • PDF