• Title/Summary/Keyword: Laser Head

Search Result 301, Processing Time 0.024 seconds

Development of Intelligent Filler Wire Feeding Device for Improvement of Weld quality (용접부 품질향상을 위한 지능형 용접 와이어 공급 장치 개발)

  • Lee Jae-Seok;Sohn Young-Il;Park Ki-Young;Lee Kyoung-Don
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.7 s.184
    • /
    • pp.59-66
    • /
    • 2006
  • In laser welding, automatic seam tracking is important to adjust the laser head position in real time as it moves along the seam. Also if the joint gap is occurred, filling the missing material into the joint gap is necessary to prevent welding defects and bad welding quality. In general, the joint gap width is not constant along the seam due to a variety of reason. So it is essential to control the filler wire speed into the joint gap to acquire good welding quality. This paper describes an intelligent filler wire feeding device which can control 3-dimensional seam tracking and the filler wire speed by measuring the gap position and the joint gap width in laser welding. We call this device as Smart Micro Control system(SMC). To achieve this objective, we assessed weld quality in 2mm sheets of A16061 which had various gap width by using the developed device. From the experimental results, It was found the possibility that the developed device could be used in welding various 3-dimensional structures.

Calibration of Laser Scribe Force Using Finite Element Method (유한요소법을 이용한 레이저 화선력의 보정)

  • Chung, Chul-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1319-1324
    • /
    • 2007
  • Accurately controlling the shape of the read/write head structure is critical in the performance of a modem hard disk drive. The sliders investigated are composed of alumina and titanium carbide(AITiC) and act as an air bearing when passing over the disks. Controlling the curvature of the slider is of primary importance. A laser scribing system that produces curvature by inducing residual stress into the slider can be utilized. Predicting the curvature created by a pattern of scribes is of great importance to increase the control over the sliders' shape. The force system that produces stresses similar to the laser scribing is applied to the finite element analysis model. The curvatures created by the force system are calibrated to experimental measurements.

  • PDF

Salvage Treatment of Nasopharyngeal Carcinoma (비인강암종의 구제치료)

  • Choi Jong-Ouck;Kim Yong-Hwan;Min Hun-Ki;Choi Geon;Kweon Hee-Weon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.12 no.1
    • /
    • pp.3-7
    • /
    • 1996
  • Nasopharyngeal carcinoma(NPC) is a disease whose primary initial treatment is radiation. Results of radiation therapy in early stage disease is promising; however, in stage IV disease, the best reported five-year survival is only about 30%. In patients with post-radiation recurrent disease, radiation controls only a small portion of patients, as well as being associated with significant radiation injury. In this paper we discuss the use of salvage treatment modalities for post-radiation recurrence. A retrospective chart review and analysis of salvage treatment results were performed for 39 patients with recurrent post-radiation NPC and positive cervical lymph nodes during the period beginning 1985 until 1995. Mean age of these patients was 52.3$\pm$10.37 years and male: female ratio was 1.8 : 1. Twenty patients were treated with salvage treatment, and ten patients were treated by salvage chemotherapy. A total of nine patients underwent surgical salvage treatment, including neck dissection(6), transnasal laser surgery and booster radiotherapy(2), and primary surgery(1). Salvage treatment were effective in reducing patients' pain in twenty patients (51.3%) and prolonging life in nine patients(23.1%); however, recurrence of disease within six months and/or residual disease by clinical or radiologic exam was noted in all patients receiving salvage radiotherapy, chemotherapy, laser surgery with radiotherapy, and primary site surgery. In the group undergoing salvage neck dissection, three patients(50%) were disease free for at least two years. Of the different modalities, radiotherapy was associated with the best quality of life while catastrophic salvage surgery resulting in insignificant prolongation of life was associated with the poorest quality of life. We conclude that salvage surgery is the optimal choice of treatment for regional recurrence such as nodal failure, however palliative salvage therapy could be preferred in other cases with recurrent post-radiation NPC.

  • PDF

A Study on the Diode Laser Surface Hardening Treatment of Cast Iron for Die Material(II) -Comparison of Hardening Characteristics by the Parts Applied Heat Treatment- (금형재료용 주철의 다이오드 레이저 표면경화처리에 관한 연구(II) - 표면경화의 적용 부위에 따른 열처리 특성의 차이 -)

  • Kim, Jong-Do;Song, Moo-Keun;Hwang, Hyun-Tae
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1048-1054
    • /
    • 2011
  • Laser surface hardening process is the method of hardening surface by inducing rapid self quenching of laser injected area through transfer of surface heat to inside after rapid heating of laser injected area only by high density energy heat source. This surface treatment method does not involve virtually any thermal deformation by heat treatment nor accompanies any other process after surface hardening treatment. In addition, allowing local machining, this method is a surface treatment method suitable for die with complicated shape. In this study, die material cast iron was surface-treated by using high power diode laser with beam profile suitable for heat treatment. Since the shapes of die differ by press die process, specimens were heat-treated separately on plane and corner depending on the applied parts. At this time, corner heat treatment was done with optic head inclined at $10^{\circ}$. As a result, corner heat treatment easily involves concentration of heat input due to limitation of heat transfer route by the shapes compared with plane part, so the treatment accomplished hardening at faster conveying speed than plane heat treatment.

Development of rotational pulse-echo ultrasonic propagation imaging system capable of inspecting cylindrical specimens

  • Ahmed, Hasan;Lee, Young-Jun;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.657-666
    • /
    • 2020
  • A rotational pulse-echo ultrasonic propagation imager that can inspect cylindrical specimens for material nondestructive evaluations is proposed herein. In this system, a laser-generated ultrasonic bulk wave is used for inspection, which enables a clear visualization of subsurface defects with a precise reproduction of the damage shape and size. The ultrasonic waves are generated by a Q-switched laser that impinges on the outer surface of the specimen walls. The generated waves travel through the walls and their echo is detected by a Laser Doppler Vibrometer (LDV) at the same point. To obtain the optimal Signal-to-Noise Ratio (SNR) of the measured signal, the LDV requires the sensed surface to be at a right angle to the laser beam and at a predefined constant standoff distance from the laser head. For flat specimens, these constraints can be easily satisfied by performing a raster scan using a dual-axis linear stage. However, this arrangement cannot be used for cylindrical specimens owing to their curved nature. To inspect the cylindrical specimens, a circular scan technology is newly proposed for pulse-echo laser ultrasound. A rotational stage is coupled with a single-axis linear stage to inspect the desired area of the specimen. This system arrangement ensures that the standoff distance and beam incidence angle are maintained while the cylindrical specimen is being inspected. This enables the inspection of a curved specimen while maintaining the optimal SNR. The measurement result is displayed in parallel with the on-going inspection. The inspection data used in scanning are mapped from rotational coordinates to linear coordinates for visualization and post-processing of results. A graphical user interface software is implemented in C++ using a QT framework and controls all the individual blocks of the system and implements the necessary image processing, scan calculations, data acquisition, signal processing and result visualization.

Design of Ultrasonic Vibration Device using PZT Actuator for Precision Laser Machining (압전구동기를 이용한 정밀 가공용 초음파 진동장치 설계)

  • Kim, W.J.;Fei, L.;Cho, S.H.;Park, J.K.;Lee, M.G.
    • Laser Solutions
    • /
    • v.14 no.2
    • /
    • pp.8-12
    • /
    • 2011
  • As the aged population grows around the world, many medical instruments and devices have been developed recently. Among the devices, a drug delivery stent is a medical device which requires precision machining. Conventional drug delivery stent has problems of residual polymer and decoating because the drug is coated on the surface of stent with the polymer. If the drug is impregnated in micro hole array on the surface of the stent, the problem can be solved. Micro sized holes are generally fabricated by laser machining; however, the fabricated holes do not have an enough aspect ratio to contain the drug or a good surface finish to deliver it to blood vessel tissue. To overcome these problems, we propose a vibration-assisted machining mechanism with PZT (Piezoelectric Transducers) for the fabrication of micro sized holes. If the mechanism vibrates the eyepiece of the laser machining head, the laser spot on the workpiece will vibrate vertically because objective lens in the eyepiece shakes by the mechanism's vibration. According to the former researches, the vibrating frequency over 20kHz and amplitude over 500nm are preferable. The vibration mechanism has cylindrical guide, hollowed PZT and supports. In the cylinder, the eyepiece is mounted. The cylindrical guide has upper and low plates and side wall. The shape of plates and side wall are designed to have high resonating frequency and large amplitude of motion. The PZT also is selected to have high actuating force and high speed of motion. The support has symmetrical and rigid characteristics.

  • PDF

Phonosurgery after Laser Cordectomy (레이저 성문절제술 후의 음성수술)

  • So, Yoon-Kyung;Son, Young-Ik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.19 no.1
    • /
    • pp.11-15
    • /
    • 2008
  • Endoscopic laser cordectomy is known as an oncologically sound procedure for T1 and selected T2 glottic carcinoma ; it has comparable local control rate and better long-term laryngeal preservation rate when compared with those of radiotherapy. Even if results of the reported voice outcome studies after surgery or radiotherapy are diverse and controversial, resection deeper than the body layer of the vocal fold (type III, IV, V cordectomy) usually leads to aerodynamic insufficiency during phonation and results in poor voice quality. A keyhole defect or development of synechiae at the anterior commissure after type VI cordecomy may also result in unsatisfactory vocal outcome. However, many advances in phonosurgical techniques are reported to be successfully applied in the reconstruction of glottal defect that is subsequent to endoscopic laser cordectomy. In case of glottal insufficiency, voice restoration can be achieved by means of augmentation of the paraglottic space or medialization of the excavated vocal fold. Injection laryngoplasty with synthetic materials or autologous fat is gaining its popularity for restoring minor glottal volume defect because of its convenience. Laryngeal framework surgery, especially type I thyroplasty with premade implant systems or Gore-Tex, is most frequently used to correct larger glottic volume defect. In case of anterior commissural keyhole defect, additional procedure including laryngofissure may be required. For anterior commissural synechiae, laryngeal keel may be inserted for several weeks or mitomycin-C may be repeatedly applied after the division of adhesive scar to prevent restenosis. In this paper, current concepts and the authors' experiences of phonosurgical reconstruction of vocal function after endoscopic cordectomy will be introduced.

  • PDF

Effects of Ultrasound, Laser and Exercises on Temporomandibular Joint Pain and Trismus Following Head and Neck Cancer

  • Elgohary, Hany Mohamed;Eladl, Hadaya Mosaad;Soliman, Ashraf Hassan;Soliman, Elsadat Saad
    • Annals of Rehabilitation Medicine
    • /
    • v.42 no.6
    • /
    • pp.846-853
    • /
    • 2018
  • Objective To compare the effects of low intensity ultrasound (LIUS), traditional exercise therapy (TET), low level laser therapy (LLLT) and TET on temporomandibular joint (TMJ) pain and trismus following recovery from head and neck cancer (HNC). Methods Sixty participants following, who had experienced HNC, were randomly allocated to three groups of 20 people each. Each group received different therapy. Group A received LIUS and TET; group B received LLLT and TET; while group C received TET. All 60 participants were evaluated under the visual analog scale (VAS), the University of Washington Quality of Life questionnaire (UW-QOL) and the Vernier caliper scale (VCS) at the beginning of the therapies and after 4 weeks. Results ANOVA test revealed significant improvements across all three groups with outcomes of p<0.05. The results of the UW-QOL questionnaire showed a significant difference between groups A, B and C in favor of group A (p<0.05). The VAS results showed a more improvement in group A as compared to group B (p<0.05), while there was no statistical difference between groups B and C (p>0.05). The VCS results showed more improvement for the individuals in group B as compared to those in group C (p<0.05), while there was minimal difference between groups A and B (p>0.05). Conclusion The LIUS and TET are more effective than LLLT and/or TET in reducing TMJ pain and trismus following HNC.

Effects of Cervical Sensorimotor Control Training on Pain, Function and Psychosocial Status in Patients With Chronic Neck Pain (목뼈 부위 감각운동 조절 훈련이 만성 목 통증 환자의 통증과 기능, 심리사회적 수준에 미치는 영향)

  • Min, In-gi;Kim, Suhn-yeop
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.36-46
    • /
    • 2021
  • Background: It is reported that the proprioceptive sensation of patients with neck pain is reduced, and neck sensory-motor control training using visual feedback is reported to be effective. Objects: The purpose of this study is to investigate how sensorimotor control training for the cervical spine affects pain, function, and psychosocial status in patients with chronic cervical pain. Methods: The subjects consisted of 36 adults (male: 15, female: 21) who had experienced cervical spine pain for more than 6 weeks. An exercise program composed of cervical stabilization exercise (10 minutes), electrotherapy (10 minutes), manual therapy (10 minutes), and cervical sensorimotor control training (10 minutes) was implemented for both the experimental and the control groups. The cervical range of motion (CROM) and head repositioning accuracy were assessed using a CROM device. In the experimental group, the subjects wore a laser device on the head to provide visual feedback while following pictures in front of their eyes; whereas, in the control group, the subjects had the same training of following pictures without the laser device. Results: There were no statistically significant differences between the two groups in pain, dysfunction, range of motion, or psychosocial status; however, post-test results showed significant decreases after 2 weeks and 4 weeks compared to baseline (p < 0.01), and after 4 weeks compared to after 2 weeks (p < 0.01). The cervical joint position sense differed significantly between the two groups (p < 0.05). Conclusion: In this study, visual feedback enhanced proprioception in the cervical spine, resulting in improved cervical joint position sense. On the other hand, there were no significant effects on pain, dysfunction, range of motion, or psychosocial status.

A Study on the Measurement of Temperature and Soot in a Visualized D.I Diesel Engine Using the Laser Diagnostics (광계측 기법을 이용한 직분식 디젤 가시화 엔진내의 온도 및 매연 측정에 관한 연구)

  • Han, Yong-Taek;Lee, Ki-Hyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.5
    • /
    • pp.38-47
    • /
    • 2007
  • Based upon temperature calibration using the diffusion flame, the temperature and soot concentration of the turbulent flame in a visualized Diesel engine's turbulent flow of flame was qualitatively measured. Two different heads were used to judge the effect of swirl ratio within the combustion chamber. It was possible to measure the highest temperature of the non-swirl head visualized engine which is approximately 2400K, and that the swirl head engine managed up to 2100K. Also, the more the pressure of the spray increases the more the temperature increases due to the improved combustion situation with respect to the visualized diesel engine soot. This experiment also revealed that the KL factor was high where the fuel collided with the walls of the combustion chamber. Moreover the KL factor was high on parts of the chamber where the temperature dropped rapidly.