• Title/Summary/Keyword: Laser Head

Search Result 301, Processing Time 0.027 seconds

Comparison of Mechanical properties and Surface Friction of White Metals Produced by Centrifugal and Laser Cladded on SCM440 (원심주조방식과 레이저 클래딩 증착법을 통한 화이트메탈의 기계 및 마찰특성 비교)

  • Jeong, Jae-Il;Kim, Dong-Hyuk;Park, Jin-Young;Oh, Joo-Young;Choi, Si-Geun;Kim, Seock-Sam;Cho, Young Tae;Lee, Ho;Ham, Seung-Sik;Kim, Jong-Hyoung
    • Tribology and Lubricants
    • /
    • v.34 no.3
    • /
    • pp.84-92
    • /
    • 2018
  • Bearings are essential for reducing vibration and wear, in order to achieve high durability and increase longevity. White metal treatment of tilting pads via centrifugal casting method has the possibility of increasing durability. However, this manufacturing method has drawbacks such as long processing time, high defect rate, and harmful health effects. Laser cladding deposition technique is a powerful method that can address these issues by decreasing the processing time and providing good adhesion. In this study, we suggest optimum conditions for laser cladding deposition that can be used in industrial applications. We deposited a soft white metal layer on SCM440 that is primarily used in shafts to minimize wear of bearing pads. During the laser deposition process, we controlled factors such as laser power, powder feed rate, and laser head speed to determine the optimum conditions. In addition, we measured the hardness using micro Vickers, and performed field emission scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, and friction tests to investigate the mechanical properties and surface characteristics for different parameters. Based on the experimental results, we suggest that laser power, powder feed rate, and laser head speed of 1.3 kW, 2.5 rpm, and 10 mm/s, respectively, constitute the optimum conditions for producing white metals using laser cladding.

Development of Remote Laser Welding-Cutting Process for Maintenance of Hydraulic Connection Module on ITER Project (핵융합 발전로 냉각수 연결모듈의 원격 유지보수를 위한 레이저 용접-절단 공정개발)

  • Kim, Yong;Park, Ki-Young;Lee, Kyoung-Don
    • Journal of Welding and Joining
    • /
    • v.30 no.1
    • /
    • pp.51-58
    • /
    • 2012
  • To assess hydraulic connections between sub-components of the International Thermonuclear Experimental Reactor (ITER) diagnostic port plug, the laser welding and ablation cutting process were investigated in order to be applied the remote handling maintenance. In this study, laser ablation cutting, which vaporizes a small amount of solid material directly into gas by focusing a laser beam of high density energy, is adopted in order to overcome the limitation of the normal laser cutting technology that the head should be placed as close to the work piece as possible to blow out melt metal at a distance. Complete cutting of a work piece is obtained by repetitive multi-passes of the laser beam. The welding and cutting process were tested on the sample work pieces and finally on a prototype of a hydraulic connection module for remote handling. The results showed that this process can be a promising candidate for hydraulic connections by remote handling.

Laser Peening Application for PWR Power Plants (비등수형 원자로 발전소에의 레이저 피닝 적용기술)

  • Kim, Jong-Do;SANO, Yuji
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.13-18
    • /
    • 2016
  • Toshiba has developed a laser peening system for PWRs(pressurized water reactors) as well after the one for BWRs(boiling water reactors), and applied it for BMI(bottom-mounted instrumentation) nozzles, core deluge line nozzles and primary water inlet nozzles of Ikata Unit 1 and 2 of Shikoku Electric Power Company since 2004, which are Japanese operating PWR power plants. Laser pulses were delivered through twin optical fibers and irradiated on two portions in parallel to reduce operation time. For BMI nozzles, we developed a tiny irradiation head for small tubes and we peened the inner surface around J-groove welds after laser ultrasonic testing (LUT) as the remote inspection, and we peened the outer surface and the weld for Ikata Unit 2 supplementary. For core deluge line nozzles and primary water inlet nozzles, we peened the inner surface of the dissimilar metal welding, which is of nickel base alloy, joining a safe end and a low alloy metal nozzle. In this paper, the development and the actual application of the laser peening system for PWR power plants will be described.

Laser beam decontamination of metallic surfaces with a pulsed (150 W) Nd: YAG laser

  • Anne-Maria Reinecke;Margret Acker;Steffen Taut;Marion Herrmann;Wolfgang Lippmann;Antonio Hurtado
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4159-4166
    • /
    • 2023
  • Laser decontamination of radioactive surfaces is an innovative technology. Our contribution to improving this technology includes studies on laser beam decontamination with a pulsed laser of an average power of 150 W, equipped with a hand guided working head. Our investigations are focused on metallic surfaces typical in nuclear power plants, such as stainless steel, bright and rusted mild steel, galvanized steel, and painted steel. As typical nuclides of contaminated surfaces we chose Co-60 and Cs-137, the most frequently occurring nuclides in many nuclear plant components; Sr-85 as a representative of Sr-90, the potentially most harmful fission nuclide; and Am-241 as a representative of the minor alpha-radiation emitting actinides. Here, we present our results of decontamination and recovery ratios. Decontamination ratios of 90-100% were achieved on different surfaces.

Clinical Application of Gold Nanoparticles for Diagnosis and Treatment

  • Baek, Seung-Kuk
    • Medical Lasers
    • /
    • v.10 no.2
    • /
    • pp.61-67
    • /
    • 2021
  • Advances in nanobiotechnology have presented numerous possibilities of more effective diagnostic and therapeutic options. In particular, gold nanoparticles have demonstrated the potential for application in molecular imaging and treatment of cancers, including drug delivery system of certain target molecules, enhancement of radiation therapy, and photothermal treatment. This review discusses the properties, mechanism of action, and clinical application of gold nanoparticles. Although the safety of nanoparticles is yet to be ascertained, there is no doubt that in the future, nanotechnology will play an important role in the development and enhancement of a wide range of diagnostic and treatment modalities.

Development of super large size laser digitizer system

  • Saito, Norio;Hirose, Toshiyuki;Abe, Makoto;Suvama, Masahiro;Fujimoto, Ikunatu;Koizumi, Shinichi;Yaname, Ryuichi;Murakami, Azuma
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10b
    • /
    • pp.1200-1203
    • /
    • 1990
  • Recently, the CAD/CAM system to automatically design and process are used in almost every industry world. We designed an original digitizer system to digitize a real size car drawing. We succeeded in the development of super large size Laser Digitizer System (LDS) which has input area of 2m by 6m, resolution of 0.1mm and accuracy of .+-.0.5mm. This Laser Digitizer System can use in design of cars, ships, planes and big maps. Also can use in sensing the position of nozzle head of laser processing system, and so on.

  • PDF

LASER MICROWELDING FOR ELECTRICAL INTERCONNECTION IN BIOMEDICAL TECHNOLOGY (의료용 전기 접점부의 마이크로 레이저 용접)

  • ;B.K. Paul;J. Boogaard
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.45-48
    • /
    • 2003
  • Over the past few decades, there has been increasing research and commercial activity in invasive and non-invasive biomedical technology. One important challenge to developing these devices involves the increasing density of electrical interconnects. Resistance spot welding is limited in the density of interconnect based on either the size of welding head or the positional precision with which a weld can be made. Development of an automated laser microwelding system would permit the continued advancement of these important biomedical technologies. The objective of this work is to demonstrate the application of pseudo-pulse Nd:YAG laser technology as an alternative to resistance spot welding in performing electrical interconnection within biomedical products. To date, some experiments have been conducted by using a pseudo-pulse 1064 nm Nd:YAG laser, a successful weld of a 25 ${\mu}{\textrm}{m}$ diameter Pt/Ir wire to a 316 stainless steel shim can be made. Another application involves welding clips, which may be used for external interconnection, to electrodeposited nickel domes that make particular interconnections to specific insulated wires within a cable. These results show a great deal of promise for developing such a process.

  • PDF

Myxoma in the Laryngeal Ventricle and the True Vocal Cord:A Case Report (후두실과 진성대에 발생한 점액종 1예)

  • Kim, Seung-Woo;Yum, Dong-Jin;Kang, Jae-Ho;Kim, Choon-Dong
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.67-70
    • /
    • 2007
  • Myxoma is an uncertain mesenchymal cell origin, characterized by irregular round, stellate or spindle cells surrounded by the matrix containing abundant mucoid material and scant vascularity. Their occurrence in descending order of frequency is in the heart, subcutaneous tissue, bone and genitourinary tract. In the head and neck region, the most predilection sites are mandible and maxilla(more than 80%). Laryngeal myxoma is extremely rare:only 5 cases have been reported in the English literature. We report a rare case of laryngeal myxoma. A 60-year-old man with hoarseness visited the out-patient department. The mass was located between the vocal fold and the vocal ligament, filling with the left laryngeal ventricle. We planned the laryngo-microsurgery and successfully excised using $CO_2$ laser. The histopathologic finding revealed the myxoma. After 18 months of surgery, there is no evidence of recurrence and mucosal scarring in the vocal fold. This report is the first case of laryngeal myxoma involving the laryngeal ventricle and the true vocal cord together.

Experimental Analysis of Bubble Dynamics Induced by Pulsed-Laser Heating of Absorbing Liquid (흡광 액체의 펄스 레이저 가열에 의해 생성된 기포 거동의 실험적 해석)

  • Jang Deok-Suk;Hong Jong-Gan;Choa Sung-Hoon;Kim Dong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.5 s.248
    • /
    • pp.413-421
    • /
    • 2006
  • The bubble dynamics induced by direct laser heating is experimentally analyzed as a first step to assess the technical feasibility of laser-based ink-jet technology. To understand the interaction between laser light and ink, the absorption spectrum is measured for various ink colors and concentrations. The hydrodynamics of laser-generated bubbles is examined by the laser-flash photography. When an Ar ion laser pulse (wavelength 488 nm) with an output power up to 600 mW is incident on the ink solution through a transparent window, a hemispherical bubble with a diameter up to ${\sim}100{\mu}m$ can be formed with a lifetime in a few tens of microsecond depending on the laser power and the focal-spot size. Parametric study has been performed to reveal the effect of laser pulse width, output power, ink concentration, and color on the bubble dynamics. The results show that the bubble generated by a laser pulse is largely similar to that produced by a thin-film heater. Consequently, the present work demonstrates the feasibility of developing a laser-actuated droplet generation mechanism for applications in ink-jet print heads. Furthermore, the results of this work indicate that the droplet generation frequency is likely to be further increased by optimizing the process parameters.

Laryngeal Verruca Vulgaris : A Case Report and Review of Literature (성대에서 진단된 심상성 사마귀 1례)

  • Han, Jae Sang;Hong, Soon Be;Lee, Philip;Park, Young Hak
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.27 no.2
    • /
    • pp.141-144
    • /
    • 2016
  • Verruca vulgaris of the larynx (VVL) is an extremely rare disease that can be easily misdiagnosed as papillary keratosis, squamous papilloma or verrucous carcinoma, which would have led to needless operation. We experienced a case of VVL in a 66-year-old man with 1-year history of progressive hoarseness. Whitish lesions in both vocal cords were observed by using indirect laryngoscopy and completely removed via microlaryngeal surgery with $CO_2$ laser.

  • PDF