• Title/Summary/Keyword: Largest gap

Search Result 131, Processing Time 0.026 seconds

Response Characteristics of Charged Particle Type Display (대전입자형 디스플레이의 응답특성)

  • Lee, Dong-Jin;Kim, Young-Cho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.2
    • /
    • pp.169-173
    • /
    • 2009
  • We studied driving characteristics according to the ratio of mass and charging (m/q) value for charged toner particles with black and yellow color in charged particle type display panel. After biasing rectangle pulse to the transparency electrodes of putted panel with toner particles, its response time and contrast ratio are simultaneously measured using a laser as a optical source, photodiode as a detector and reflective system. As a results, contrast ratio is largest at the shortest response time region which is different to the particle because of m/q. We proposed relational equation for response time, m/q, cell gap and biasing voltage. It has not been studied and reported to analyze the relationship of response time, biasing voltage, lumping phenomena, cell gap, and contrast ratio for toner particle type display.

Comparison of middle-aged women's bodice pattern using 3D data -focused on the DC Suite program-

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.1
    • /
    • pp.91-102
    • /
    • 2018
  • The purpose of this study is to develop an excellent bodice prototype that is adapted to the body shape of middle-aged women using 3D measurement data. In the evaluation of appearance, S pattern 4.00, B pattern 2.80, E pattern 2.40, L pattern 1.40 were shown in order, and the best fit of S pattern was evaluated as excellent. As a result of looking at the color distribution chart to find out the amount, E pattern and S pattern were not space in the front bust, armhole, and the back waist line. The B pattern and the L pattern were marked in blue because of insufficiency space in the back neck. As a result of evaluation the amount of air gap in the clothing, the air gap of the bust was 0.12, which is the largest pattern of B. Next, the L pattern appears as a tight circle with smallest air gap in the order of the S pattern 0.096, the E pattern 0.08, and the L pattern 0.003. The S pattern was evaluated to be the most appropriate for the body shape of middle-aged women. But the waist and back were slightly tight. Middle-aged women have larger shoulder-related items and larger waist circumference. Therefore, when you set the perimeter item, you should add 1-2cm of space amount and give extra space to the circumference area.

Green Bonds Driving Sustainable Transition in Asian Economies: The Case of India

  • PRAKASH, Nisha;SETHI, Madhvi
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.8 no.1
    • /
    • pp.723-732
    • /
    • 2021
  • On September 25, 2015, 193 countries of the United Nations (UN) General Assembly, signed the 2030 Agenda to work towards attaining 17 Sustainable Development Goals (SDGs) and its associated 169 targets and 232 indicators. With one of the largest renewable energy programs, India is well-poised to be a role model for low-carbon transformation to other Asian countries. However, bridging the financing gap is critical to ensure that the country meets its SDG targets. Though the SDGs identified by the UN are broad-based and interdependent, for ease of analysis we have grouped them into five themes - people, planet, prosperity, peace, and partnership - based on existing UN models. This paper investigates the financing gap for 'green' projects linked to planet-related SDG targets in India. It builds an argument for utilizing green bonds as an instrument to bridge the gap. After establishing the potential of green bonds in raising the finance to meet India's planet-related SDG targets, we look at the current policy landscape and suggest recommendations for successful execution. The paper concludes that deepening of the corporate fixed income securities market and firming up guidelines in line with India's climate action plans are inevitable before green bonds can be considered a viable financing option.

Structural Deflection Analysis of Robot Manipulator for Removing Nuclear Fuel Rod in Nuclear Reactor Vessel (원자로내 핵연료봉 제거 로봇 구조물의 휨변형구조해석)

  • 권영주;김재희
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1999.04a
    • /
    • pp.203-209
    • /
    • 1999
  • In this study, the structural deflection analysis of robot manipulator for removing nuclear fuel rod from nuclear reactor vessel is performed by using general purpose finite element code (ANSYS). The structural deflection analysis results reported in this study is very required for the accurate design of robot system. The structural deflection analysis for the manipulator's structural status at which the gripper grasps and draws up the nuclear fuel rod is done, For this beginning structural status of robot manipulator's removing motion, the reaction forces at each joint have static maximum values as reported in the reference(6), and so these forces may cause the maximum deflection of robot structure. The structural deflection analysis is performed for selected four working cases of the proposed structural model and results on deformation, stress for the manipulator's solid body and the deflection at the end of robot manipulator's gripper are calculated. And further, the same analysis is performed for the slenderer manipulator with cross section reduced by one-fifth of each side length of proposed model. The analysis is performed not only for the nuclear fuel rod with weight load of 300kg but also for nuclear fuel rods with weight loads of 100kg, 200kg, 400kg and 500kg. The static structural deflection analysis results show that the deflection value increases as the load increases and the largest value (corresponding to the weight load of 500kg in case 1) is much smaller than the gap distance between nuclear fuel rods. but the largest value for the slenderer manipulator is almost as large as the gap distance, Hence, conclusively, the proposed manipulator's structural model is acceptably safe for mechanical design of robot system.

  • PDF

A STUDY ON MARGINAL ADAPTATION OF READY-MADE STAINLESS STEEL CROWN TO THE PRIMARY MOLAR (기성금관수복 유구치의 변연 적합도에 관한 연구)

  • Lee, Sun-Kyung;Lee, Gwang-Su;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.2
    • /
    • pp.389-400
    • /
    • 1996
  • In Class II amalgam restoration in deciduous molar, failure rate and incidence of recurrent caries are high as children become older. In order to preserve deciduous molars till the physiologic exfoliation time, stainless steel crown is a choice of the treatment. As a result of a careless treatment, such as overhanging margin, poor marginal adaptation, poor proximal contour and inadequate mesiodistal width give rise to interfering eruption of the adjacent teeth, recurrent caries and chronic gingival irritation and insufficient arch length respectively. In this study, 252 s.s. crowned teeth extracted due to physiologic exfoliation or periapical lesion. The purpose of this study is to analyze the marginal adaptation of stainless steel crown to the deciduous molar in order to obtain better clinical result. The results were as follows : 1. Between the length of s.s. crown and the marginal gap of crown, positive correlations were shown. 2. Largest amount of marginal gap was shown at buccal side in upper deciduous molars and lower first deciduous molar, lingual side in lower second deciduous molar. But no significant diffrence were found statistically compared to second most largest one. 3. Incidence of exposed restoration and recurrent caries were higher in proximal surface than buccal/lingual surface. And extension of restoration below the margin of s.s. crown gives rise to higher rate of recurrent caries. 4. Defect of contour was found in 34%, frequently found in lower 1st deciduous molar and upper 1st deciduous molar. 5. Marginal polishing defects were found in 23%. 6. Ledge was formed in 10% especially in lower 1st deciduous molar and lower 2nd deciduous molar. 7. 16% of the teeth had wear facet due to traumatic occlusion, 7% of them had occlusal perforation.

  • PDF

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Marginal and internal fit of 3D printed provisional crowns according to build directions

  • Ryu, Ji-Eun;Kim, Yu-Lee;Kong, Hyun-Jun;Chang, Hoon-Sang;Jung, Ji-Hye
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.225-232
    • /
    • 2020
  • PURPOSE. This study aimed to fabricate provisional crowns at varying build directions using the digital light processing (DLP)-based 3D printing and evaluate the marginal and internal fit of the provisional crowns using the silicone replica technique (SRT). MATERIALS AND METHODS. The prepared resin tooth was scanned and a single crown was designed using computer-aided design (CAD) software. Provisional crowns were printed using a DLP-based 3D printer at 6 directions (120°, 135°, 150°, 180°, 210°, 225°) with 10 crowns in each direction. In total, sixty crowns were printed. To measure the marginal and internal fit, a silicone replica was fabricated and the thickness of the silicone impression material was measured using a digital microscope. Sixteen reference points were set and divided into the following 4 groups: marginal gap (MG), cervical gap (CG), axial gap (AG), and occlusal gap (OG). The measurements were statistically analyzed using one-way ANOVA and Dunnett T3. RESULTS. MG, CG, and OG were significantly different by build angle groups (P<.05). The MG and CG were significantly larger in the 120° group than in other groups. OG was the smallest in the 150° and 180° and the largest in the 120° and 135° groups. CONCLUSION. The marginal and internal fit of the 3D-printed provisional crowns can vary depending on the build angle and the best fit was achieved with build angles of 150° and 180°.

Comparison of old-old aged women's bodice pattern using 3D anthropometric data

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.11
    • /
    • pp.111-122
    • /
    • 2018
  • The purpose of this study was to investigate the bodice prototype method suitable for the upper body shape of old-old aged women using the 3D anthropometric data. And it was to provide the basic data for the upper body garments of old-old aged women. In the overall appearance evaluation, the B pattern was rated as 4.00, and it was evaluated as the most suitable for the bodice prototype of the old-old aged woman. The E pattern was rated lower than normal, and the L pattern and the S pattern were found to be inadequate for older female bodice prototypes. As a result of the measurement of the waist and bust air gap of bodice prototype, the air gap of the bust was not significantly different between the patterns. But the waist air gap showed the largest difference between the L pattern and the S pattern. As a result of evaluating the appearance, the amount of space in the state of 3D simulation, and the air gap, the pattern B appeared to be the most appropriate prototype for the old-old aged women's body shape. However, there is a tendency that the shoulder end point is biased toward the back, so it is necessary to set the inclination of the back shoulder line to be more gentle. Conversely, the front shoulder should be more inclined. In the case of the 3D simulation, the B pattern showed that the other parts generally fit well. In the case of the 3D simulation program used in this study, it was evaluated that it is suitable only for the normal body shape because it is impossible to set the isometric angle which is one of the characteristics of the older female body shape. A study on the bodice prototype suitable for the bent body shape should be carried out through experiments on the actual body shape of various elderly women. In order to cope with the increase of elderly people who are familiar with digital, I think it is necessary to develop an avatar that reflects the old female body shape.

Push-out bond strength and marginal adaptation of apical plugs with bioactive endodontic cements in simulated immature teeth

  • Maria Aparecida Barbosa de Sa;Eduardo Nunes ;Alberto Nogueira da Gama Antunes ;Manoel Brito Junior ;Martinho Campolina Rebello Horta ;Rodrigo Rodrigues Amaral;Stephen Cohen ;Frank Ferreira Silveira
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.53.1-53.11
    • /
    • 2021
  • Objectives: This study evaluates the bond strength and marginal adaptation of mineral trioxide aggregate (MTA) Repair HP and Biodentine used as apical plugs; MTA was used as reference material for comparison. Materials and Methods: A total of 30 single-rooted teeth with standardized, artificially created open apices were randomly divided into 3 groups (n = 10 per group), according to the material used to form 6-mm-thick apical plugs: group 1 (MTA Repair HP); group 2 (Biodentine); and group 3 (white MTA). Subsequently, the specimens were transversely sectioned to obtain 2 (cervical and apical) 2.5-mm-thick slices per root. Epoxy resin replicas were observed under a scanning electron microscope to measure the gap size at the material/dentin interface (the largest and smaller gaps were recorded for each replica). The bond strength of the investigated materials to dentin was determined using the push-out test. The variable bond strengths and gap sizes were evaluated independently at the apical and cervical root dentin slices. Data were analyzed using descriptive and analytic statistics. Results: The comparison between the groups regarding the variables' bond strengths and gap sizes showed no statistical difference (p > 0.05) except for a single difference in the smallest gap at the cervical root dentin slice, which was higher in group 3 than in group 1 (p < 0.05). Conclusions: The bond strength and marginal adaptation to root canal walls of MTA HP and Biodentine cement were comparable to white MTA.

Modeling the Relationship between Expected Gain and Expected Value

  • Won, Eugene J.S.
    • Asia Marketing Journal
    • /
    • v.18 no.3
    • /
    • pp.47-63
    • /
    • 2016
  • Rational choice theory holds that the alternative with largest expected utility in the choice set should always be chosen. However, it is often observed that an alternative with the largest expected utility is not always chosen while the choice task itself being avoided. Such a choice phenomenon cannot be explained by the traditional expected utility maximization principle. The current study posits shows that such a phenomenon can be attributed to the gap between the expected perceived gain (or loss) and the expected perceived value. This study mathematically analyses the relationship between the expectation of an alternative's gains or losses over the reference point and its expected value, when the perceived gains or losses follow continuous probability distributions. The proposed expected value (EV) function can explain the effects of loss aversion and uncertainty on the evaluation of an alternative based on the prospect theory value function. The proposed function reveals why the expected gain of an alternative should exceed some positive threshold in order for the alternative to be chosen. The model also explains why none of the two equally or similarly attractive options is chosen when they are presented together, but either of them is chosen when presented alone. The EV function and EG-EV curve can extract and visualize the core tenets of the prospect theory more clearly than the value function itself.