대형 변압기 방진장치개발 (Development on a Vibration Reducing Element for the Large Transformers)

  • 이준신;이욱륜;손석만;이상국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.259-262
    • /
    • 2005
  • The large transformers used in the electric power company become targets of public complaints because of those characteristics generating high-level noise. Reducing vibration level is the basis of noise control for the large transformers. For this reason, a vibrating reducing element is developed for the large transformers with a sub-element enduring seismic movement. Large attenuation of vibration is achieved by applying the element to the large transformers in a substation.

  • PDF

대용량 변압기유의 전기적특성에 관한 연구 (A Study on the Electrical Properties of Transformer Oils for Large Power)

  • 이용우;김왕곤;홍진웅
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.81-88
    • /
    • 1996
  • In order to investigate the electrical properties of transformer oils for large power, the characteristics of AC and Impulse breakdown in gap length of 1.0~2.5mm and that of volume resistivity were researched in temperature range of 20~$100^{\circ}C$. An geometrical capacitance of electrode with coaxial cylindrical shape for measuring the volume resistivity was 16pF, and highmegohm meter with model no. VMG-1000 was used, and also the applied voltage were DC 100, 250 and 500V. In the dependance of breakdown characteristics due to electrode gap length, it was confirmed that breakdown voltage was nearly uniform by volume effect according to the increase of gap. In the characteristics for AC breakdown, the dielectric strength was increased to $90^{\circ}C$ but decreased over $90^{\circ}C$, and also in case of impulse breakdown, it was increased to 7$0^{\circ}C$ and at dated $70^{\circ}C$ over in temperature range. The calculated mobility of oils in the characteristics for impulse breakdown were about $10^{-5}$~$10^{-4}cm^2/V{\cdot}S$, and the value of volume resistivity was almost invariable in low temperature range, regardless of voltage by the stable thermal properties, and it indicated a peak at $50^{\circ}C$ and had a sudden change to decrease over that temperature, and also the value of volume resistivity in 250V/mm at $80^{\circ}C$ is suitable for the International electrical standards, it was confirmed.

  • PDF

345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

약간 감독되는 포인트 클라우드 분석에서 일반 로컬 트랜스포머 네트워크 (General Local Transformer Network in Weakly-supervised Point Cloud Analysis)

  • ;이태호;;최필주;이석환;권기룡
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2023년도 추계학술발표대회
    • /
    • pp.528-529
    • /
    • 2023
  • Due to vast points and irregular structure, labeling full points in large-scale point clouds is highly tedious and time-consuming. To resolve this issue, we propose a novel point-based transformer network in weakly-supervised semantic segmentation, which only needs 0.1% point annotations. Our network introduces general local features, representing global factors from different neighborhoods based on their order positions. Then, we share query point weights to local features through point attention to reinforce impacts, which are essential in determining sparse point labels. Geometric encoding is introduced to balance query point impact and remind point position during training. As a result, one point in specific local areas can obtain global features from corresponding ones in other neighborhoods and reinforce from its query points. Experimental results on benchmark large-scale point clouds demonstrate our proposed network's state-of-the-art performance.

압전 변압기의 제어 방식에 따른 모델링 및 안정화분석 (Stabilization Analysis of Piezo-electric Converter for PFM and PWM Control)

  • 윤석택;박성우;원영진;이진호;김진희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.401-401
    • /
    • 2009
  • Recently, demands for the development of compact, lightweight power supplies with higher power density and higher efficiency have been increased. Since Piezoelectric Transformer (PT) was emerged in device and material industry, it has been suggested as a viable alternative to the magnetic transformer in some applications. PT has some advantages such as low profile and mechanical energy transfer with little electromagnetic interface (EMI). Also, PT can provide high voltage stepping ratio with good isolation and requires no copper windings saving copper usage especially for large voltage conversion differences. Conventional control of PT converter has mainly two-way. One is the pulse frequency modulation (PFM) control method and the other is the pulse width modulation (PWM) control with frequency fixed method. It is known that the maximum PT efficiency can be obtained when it operates near the resonant frequency of the PT. And, also PT's resonant frequency moves according to the load condition. Therefore, selection of PT converter control method is very difficult. This paper analyzes general piezo-electric converter modeling and proposes a guide-line to selection of control method and stabilization control.

  • PDF

가속열화에 따른 식물성절연유의 화학적.전기적 특성 분석 (Analysis on the Chemical and Electrical Characteristic of Vegetable oil by Accelerated Aging)

  • 최순호;정중일;허창수
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.984-989
    • /
    • 2011
  • Electrical insulation is one of the most important part in a high voltage apparatus. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. Accelerated aging transformer insulating material in vegetable oil was compared to that of mineral oil. Accelerated aging oil samples produced in the oven at $140^{\circ}C$ for 500, 1000, 1500, 2000hours. And Real transformer insulation oils samples of vegetable oil and mineral oil were aged by thermal cycles repeating from $30^{\circ}C$ to $120^{\circ}C$. Samples were analyzed at 42, 63, 93, 143, 190, 240, 300 cycles. The mineral and vegetable insulating oils were investigated for breakdown voltage, water content, total acid number, viscosity, volume resistivity, insulating paper and oil permittivity, and dissolved gas analyses. The breakdown voltage of the vegetable insulating oil is higher than that found for the mineral oil; the accelerated aging progress decreased the breakdown voltage. The vegetable oil had a higher water saturation than the mineral oil; the vegetable oil has the superior water characteristics and breakdown voltage. And high viscosity of vegetable oil, care has to be taken, especially when designing the cooling system for a large transformer.

Iron Core Design of 3-Phase 40MVA HTS Power Transformer Considering Voltages per Turn

  • Lee, Chan-joo;Seok, Bok-yeol
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권2호
    • /
    • pp.54-58
    • /
    • 2004
  • This paper presents the iron core design method of a high temperature superconducting (HTS) transformer considering voltages per turn (V/T). In this research, solenoid type HTS coils were selected for low voltage (LV) winding and double pancake coils for high voltage (HV) winding, just as in conventional large power transformers. V/T is one of the most fundamental elements used in designing transformers, as it decides the core cross sectional area and the number of primary and secondary winding turns. By controlling the V/T, the core dimension and core loss can be changed diversely. The leakage flux is another serious consideration in core design. The magnetic field perpendicular to the HTS wire causes its critical current to fall rapidly as the magnitude of the field increases slowly. Therefore in the design of iron core as well as superconducting windings, contemplation of leakage flux should be preceded. In this paper, the relationship between the V/T and core loss was observed and also, through computational calculations, the leakage magnetic fields perpendicular to the windings were found and their critical current decrement effects were considered in relation to the core design. The % impedance was calculated by way of the numerical method. Finally, various models were suggested.

국산절연유의 전기적 특성에 미치는 산화방지제의 효과 (The Effect of Antioxidant in the Electrical Properties of Homemade Insulating Oil)

  • 성영권;김은배;김호윤;이덕출
    • 전기의세계
    • /
    • 제22권4호
    • /
    • pp.30-34
    • /
    • 1973
  • The main purporse of this paper is to study on the influence of temperature effect on electrical-properties, i.e., dielectric breakdown voltage, dielectric constant and resitivity of homemade insulating oil containing antioxidant. Transformer oil manufactured in Korea is taken for a sample, and this sample is classified into seven samples in which antioxidant is contained and not contained, and antioxidant is divided into three kinds of amount: 0.3%, 0.5%, 0.8%. Changing the tempe5rature of the samples by oil bath, the electric properties measured from the samples are as follows: (1) the variation of either the dielectric breakdown voltage or the resistivity are considerably large, but the dielectric constants are almost unchanging. (2) In view of electrical characteristic, the deterioration rate of the samples containing antioxidant is somewhat lower than that of other samples. (3) Nearly the same value is shown in the dielectric-breakdown voltage of the samples, in which contained the different amount of antioxidant: 0.3%, 0.5%, 0.8%, but the decrease rate of resitivity is lowest, 0.3%, of all. As the result of the experiment, This study can suggest that 0.3% be the optimum amount of antioxidant which will be added transformer oil manufactured in Korea and is useful for the understanding about the electrical properties of transformer oil containing antioxidant.

  • PDF

변류기(p-CT)를 적용한 YBCO 초전도 저항형 한류기의 ?치 특성 (Quench Behaviors of Superconducting YBCO film for Fault Current Limiters applying Protective Current Transformer)

  • 박권배;이방욱;강종성;오일성;현옥배
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.128-131
    • /
    • 2004
  • The resistive superconducting fault current limiters (SFCLs) are very attractive devices for the electric power network. But they have some serious problems when the YBCO thin films were used for the current limiting materials due to the in homogeneities caused by manufacturing process. When the YBCO films have some inhomogeneities, simultaneous quenches are difficult to achieve when the fault current limiting units are connected in series for increasing operating voltage ratings. Magnetic field application is one of the prospective way of inducing simultaneous quenches far the series-connected resistive FCL components. Magnetic field was typically generated by the fault current thorough a coil, which is connected to components of the fault current limiter in series, leaving the problem, which provides significant inductance to the power line and suppresses critical current density of the superconducting components. In this article we investigated the possible application of the protective current transformer (p-CT), which is available current source to the magnetic coil. This system inductively coupled to the circuit, therefore, remarkably reducing impedance to the circuit. The current by the protective current transformer was directly fed to the coil, generating magnetic field large enough to reduce critical current density of the components. This successfully induced simultaneous quenches of the series-connected resistive FCL components.

  • PDF