• Title/Summary/Keyword: Large temperature difference

Search Result 563, Processing Time 0.032 seconds

The Effect on Cabinet Deformation by Bead of Inner Case (가정용 냉장고의 냉동실 내벽의 비드가 케비넷 변형에 미치는 영향)

  • Cho, J.R.;Zhai, J.G.;Shin, M.G.;Kim, J.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.427-428
    • /
    • 2009
  • In the manufacture process of refrigerator cabinet, polyurethane(PU) liquid firstly is injected between outer plate and inner case in high temperature about $40^{\circ}C$, and PU foam is generated and solidified to the room temperature. There will be great residual stress in the PU foam, especially at the corners after the whole refrigerator is completely assembled. The stress condition will become more complicated under operating condition because of the large temperature difference between the freezing room and outer plate. And also, there are great differences of properties for plastic and steel which would cause different deformation under temperature gradient. The steel outer plate would expand compared to the PU foam or ABS material under operation condition, which induces a thermally bowing deformation in the refrigerator cabinet. The objective of this paper is to design an optimum bead structure or to use reinforcement in the refrigerator except for improving material properties in order to decrease the deformation.

  • PDF

An Applicability Analysis of River Water Source Heat Pump System using EnergyPlus Simulation (에너지플러스 시뮬레이션을 통한 하천수 열원 히트펌프 시스템의 적용 가능성 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.2
    • /
    • pp.10-21
    • /
    • 2022
  • A water source heat pump (WSHP) system is regarded as an energy-efficiency heating and cooling supply system for buildings due to its high energy efficiency and low greenhouse gas emissions. Recently, water sources such as river water, lake water, and raw water are attracting attention as heat sources for a heat pump system in Korea. This paper analyzed the applicability of a river water source heat pump system (RSHP). The river water temperature level was compared with the outdoor air and ground temperature levels to present applicability. In addition, the cooling and heating performance were compared through a simulation approach for the RSHP and a ground source heat pump (GSHP) applied to a large-scale office building. To compare the temperature level, the actual data were applied to the river water and the outdoor air, while the simulation results were applied to the ground circulation water. The results showed that the change in river water temperature throughout the year was similar to the change in outdoor air temperature. However, unlike the outdoor air temperature, the difference between the hourly and daily average river water temperatures was not large. The temperature level of river water was lower during the heating season and somewhat higher during the cooling season than that of the ground circulation water. Finally, the performance of the RSHP system was 13.4% lower than that of the GSHP system on an annual-based.

An Experimental Study on Hydration Heat Characteristics for Thermal Crack Analysis Based on FEM of Urea Mixed Mass Concrete (Urea 혼입 매스콘크리트의 FEM 온도균열 해석을 위한 수화발열특성에 관한 실험적 연구)

  • Mun, Dong-Hwan;Jang, Hyun-O;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.36-37
    • /
    • 2019
  • In domestic construction industry progress, construction and quality control of large structures are considered to be important as the superstructure and mass scale of structures. In the case of mass concrete, high hydration heat caused by cement hydration generates temperature stress by generating internal temperature difference with the concrete surface. These temperature stresses cause cracks to penetrate the concrete structure. A method of lowering the heat generation by incorporating Urea in order to reduce the concrete temperature crack has been proposed. In this study, the heat function coefficient for the FEM temperature crack analysis of the mass concrete containing the element was derived and the adiabatic temperature rise test was carried out according to the incorporation of the element. As a result of this experiment, the maximum temperature of 41 ± 1℃ was obtained irrespective of the amount of urea, and the maximum temperature decreased by 16.9℃ in concrete containing 40kg/㎥ of urea.

  • PDF

Analysis on Variation of Diurnal Temperature Range of Busan and Daegu according to Urbanization (도시화에 따른 부산과 대구의 일교차 변화 특성에 관한 연구)

  • Park, Myung-Hee;Lee, Joon-Soo;Ahn, Ji-Suk;Lee, Hye-Hyun;Han, In-Seong;Eom, Ki-Hyuk;Suh, Young-Sang;Kim, Hae-Dong;Bae, Hun-Kyun
    • Journal of Environmental Science International
    • /
    • v.25 no.2
    • /
    • pp.295-310
    • /
    • 2016
  • In this study, changes in daily temperature range were investigated using daily maximum and minimum temperatures of Busan and Daegu for last 81 years (1934-2014), and also characteristics of daily temperature range and seasonal fluctuations by urbanization were examined. First, elapsing changes showed a lower decreasing trend in Busan ($0.32^{\circ}C$) than Daegu ($1.28^{\circ}C$) for last 81 years. Daily temperature range showed the highest rise in winter in both Busan and Daegu. Second, daily temperature range due to urbanization showed that Busan had a pronounced decreasing trend before urbanization meanwhile Daegu showed the same trend after urbanization. On seasonal changes, the results of Busan showed a decreasing trend in summer before urbanization, and in autumn after urbanization. For Daegu, the results showed a decreasing trend in spring before urbanization, and in winter after urbanization. Seasonal fluctuations of Busan showed little difference in the pre and post-urbanization, except in winter and summer. There was large difference in daily temperature range in winter after urbanization, and in summer before the urbanization. The results in Daegu showed that there was decreasing trend of daily temperature range in all seasons after urbanization.

Empirical Orthogonal Function Analysis of Seawater Temperature in the Southeastern Hwanghae (東南黃海에서 海水溫度의 EOF 分析)

  • 이흥재;방인권
    • 한국해양학회지
    • /
    • v.21 no.4
    • /
    • pp.193-202
    • /
    • 1986
  • Spatio-temporal variabilities of seawater temperature at 0 and 30m in the southeastern Hwanghae were studied by variance and empirical orthogonal function(EOF) analysis of long records of temperature between 1967 and 1982. The spatial distribution of monthly mean sea surface temperature has a pattern similar to the long-term annual mean which decreases from south to north. On the contrary, the total variance computed from the annual mean of sea surface temperature(SST) increases from south to north. The variance of SST is found to be two times greater than that at 30m in the study area except coastal area south of Kyunggi Bay. The important variance of temperature seem s to be closely associated with the seasonal change of temperature because the first and second modes of EOF having a seasonal cycle explain 97.6% and 85.2% of variances at 0 and 30m, respectively. There is a large difference in temperature between the northern and southern parts of the study area during winter, while the difference becomes very small during summer. This might reflect that in summer the heat gain of sea surface from the incoming radiation is much more important than the heat loss or the oceanic heat advection. In summer coastal waters south of the Kyunggi Bay and around Mokpo are observed to be colder than offshore waters due to tidal mixing.

  • PDF

Design and Development of Thermoacoustic Refrigerator : II. Design Methodology and Experimental Results (열음향 냉동기의 설계 및 개발 : II. 설계 기법 및 실험 결과)

  • Park, Chul-Min;Ih, Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.53-60
    • /
    • 1996
  • In this study, a design methodology for thermoacoustic refrigerator systems is proposed based on the thermal conduction and acoustic theories, and physical characteristics of an actual thermoacoustic refrigerator are investigated. Especially, the resonator is designed for minimizing the energy loss at cold end, and the position and length of the capillary stack are optimized in order to get a large temperature difference between hot and cold ends. Experimental results show that a maximun temperature difference of 22.7$^{\circ}$ and a temperature of 4.3$^{\circ}$C at cold end are obtained by supplying an electrical input of 33W without any thermal load at cold end.

  • PDF

Modification of Retinal Function by Hypothermia and Hyperthermia

  • Chon, Young-Shin;Kim, You-Young
    • Journal of Photoscience
    • /
    • v.7 no.4
    • /
    • pp.161-167
    • /
    • 2000
  • Temperature-dependent electroretinogram responses were investigated in the dark adapted bullfrog eyes within the physiological temperature range 0-40$\^{C}$. In hypothermic process(25→0→25$\^{C}$), the amplitude of b-and c-wave decreased with lowering the temperature again. Both b-wave amplitude and threshold responses were maximal around 15$\^{C}$ during the temperature increment. Upon warming to room temperature again (25$\^{C}$), the b-wave amplitude was approximately doubled as compared to that of control without temperature changes. During the hyperthermic process (25→40→25$\^{C}$), however, the responses decreased with warming, and the wave amplitude failed to recover by cooling to 25$\^{C}$ again. As describe above, the recoveries of ERG in both processes show the striking difference. The hypothermia induces the amplification of the b-wave, that is, enhances the retinal function with the temperature recovery toward room temperature. While the hypertherima produces the decrease of the b-wave even though recovered to room temperature, which indicates an irreversible retina. The morphological alteration is shown both hypothermic and hyperthermic process, such as an appearance of large vacuoles and degenerating outer segments, more intense in hyperthermia, similar to light induced damage.

  • PDF

Plasma Surface Treatment of the Polymeric Film with Low Temperature Process (저온프로세스를 이용한 고분자필름의 플라즈마 표면처리)

  • Cho, Wook;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.486-491
    • /
    • 2008
  • The plasma processing is applied to many industrial fields as thin film deposition or surface treatment technique. In this study, we investigated large-area uniformed surface treatment of PET film at low temperature by using Scanning Plasma Method(SPM). Then, we measured difference and distribution of temperature on film's surface by setting up a thermometer. We studied the condition of plasma for surface treatment by examining intensity of irradiation of uniformed plasma. And we compared contact angles of treated PET film by using Ar and $O_2$ plasma based low temperature. In our result, surface temperature of 3-point of treating is low temperature about $22^{\circ}C$, in other hands, there is scarcely any variation of temperature on film's surface. And by using Ar plasma treatment, contact angle is lower than untreatment or $O_2$ plasma treatment. In case of PET film having thermal weak point, low temperature processing using SPM is undamaged method in film's surface and uniformly treated film's surface. As a result, Ar plasma surface treatment using SPM is suitable surface treatment method of PET film.

A Study on Air Temperature Reduction Effect and the Functional Improvement of Street Green Areas in Seoul, Korea (서울 도심 가로수 및 가로녹지의 기온 저감 효과와 기능 향상 연구)

  • Jung, Hee-Eun;Han, Bong-Ho;Kwak, Jeong-In
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.4
    • /
    • pp.37-49
    • /
    • 2015
  • The goal of this research is to examine air temperature changes according to tree type, plantation type, roadside green area structure, and green volume of street green area within a city. The plantation type that could be analyzed for comparison by tree type with over 3 species was 1 rows of tree+shrubs. The results of analysis of average air temperature difference between pedestrian and car streets vis-a-vis 1 row of tree+shrub in high air temperature areas were: Pinus densiflora, $1.35^{\circ}C$; Zelkova serrata, $1.84^{\circ}C$; Ginkgo biloba, $2.00^{\circ}C$; Platanus occidentalis, $2.57^{\circ}C$. This standard large wide canopy species was analyzed by the roadside to provide shade to have a significant impact on air temperature reduction. In terms of analysis of the relationship between plantation type of roadside trees and air temperature, the average air temperature difference for 1 row of tree type was $1.80^{\circ}C$; for 2 rows of trees it was $2.15^{\circ}C$. In terms of analysis of the relationship between the roadside green area structure and air temperature, for tree type, average air temperature $1.94^{\circ}C$: for tree+shrub type, average air temperature $2.49^{\circ}C$; for tree+mid-size tree+shrub type, average air temperature $2.57^{\circ}C$. That is, air temperature reduction was more effective in a multi-layer structure than a single layer structure. In the relationship analysis of green volume and air temperature reduction, the air temperature reduction effect was enlarged as there was a large amount of green volume. There was a relationship with the green volume of the road, the size of the tree and number of tree layers and a multi-layer structured form of planting. The canopy volume was large and there were a great number of rows of the tree layer and the plantation type of multi-layer structure, which is what is meant through a relationship with the green volume along the roadside. Green composition standards for air temperature reduction effects and functional improvement were proposed based on the result. For a pedestrian street width of 3m or less in the field being ideal, deciduous broadleaf trees in which the canopy volume is small and the structure of the tree+shrub type through the greatest 1m green bend were proposed. For a pedestrian street width of over 3m, deciduous broadleaf trees in which the canopy volume is large and is multi-layer planted with green bend over 1m, tree+mid-size tree+shrub type was proposed.

Analysis of Sea Surface Temperature Distribution Around Uljin Nuclear Power Station Using Time Series Landsat Satellite Images (시계열 Landsat 위성영상을 활용한 울진 원자력발전소 주변 해수온도 분포분석)

  • Choi, Seung-Pil;Yook, Woon-Soo;Hong, Sung-Chang;Song, Yeong-Sun
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.15 no.3
    • /
    • pp.51-57
    • /
    • 2007
  • In this study, We analyzed change of sea surface temperature due to cooling water around nuclear power station. Study area is around of Uljin nuclear power station, which is relatively large power station. There are many problems in monitering environmental change around of nuclear power station, because area is relatively large. We used Landsat 5, 7 Imagery which are useful in temperature analysis and can be easily obtained. After we georeferenced Landsat Imagery, radiance and sea surface temperature were calculated. As a result, As we compared sea surface temperature of surrounding area of nuclear power station with same area located 3 km east, there are $2.049^{\circ}C$ temperature difference.

  • PDF