• 제목/요약/키워드: Large power gas-insulated transformer

검색결과 8건 처리시간 0.027초

Fluorocarbon의 전기적 특성연구 (A study on the electrical characteristics of the fluorocarbon)

  • 허창수;조한구
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제8권2호
    • /
    • pp.217-223
    • /
    • 1995
  • In this paper, we investigated physical properties and electrical characteristics of the fluorocarbon that used as coolants for large power gas-insulated transformer. Volume resistivity of the fluorocarbon was .rho.=1.87*10$^{15}$ [.ohm.cm] at 1 atm, 27.deg. C. Dielectric constant was 1.86 and decreases as temperature increase. The breakdown voltage at 1 atm was higher than that of transformer oil. The breakdown voltage of fluorocarbon vapor was about 18kV when pressure in a test chamber increases over lkg/cm$^{2}$. When fluorocarbon was mixed with SF$_{6}$ gas, breakdown voltage of the mixed was higher than that of fluorocarbon. Then fluorocarbon leads to increase over 4kg/cm$^{2}$ in pressure as temperature increase. Therefore, when a gas-insulated transformer is manufactured, the design must be taken into consideration a high-pressure.

  • PDF

Fluorocarbon에서의 변압기권선 절연용 PET필름의 전기적 특성연구 (Electrical characteristics of PET film for wire insulation of transformer in fluorocarbon)

  • 허창수;이재복
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제9권5호
    • /
    • pp.483-489
    • /
    • 1996
  • Power transformer have many unsymmetrical structure and electric field is enhanced in that area. Those unsymmetrical area are not covered oftenly by solid insulating material which is used as a framework specially in gas transformer. By that result there is a possibility to decrease the total insulation class of the transformer. So in this study the electrical characteristic of $FC+SF_6$ mixture gas which is used as coolants for large power gas insulated transformer and its effects on electrical characteristics of structural material are investigated. Also breakdown characteristic with the tension of taping and curvature of the coil are studied which could be used as a design factor of large power transformer.

  • PDF

Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究) (A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear)

  • 김승규;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 영호남학술대회 논문집
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

345kV 승압용 변전소의 뇌격에 의한 이상전압 해석 (Analysis of Transient Voltage by Lightning Stroke at 345kV Step-up Transformer)

  • 조만영;신호전;허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권10호
    • /
    • pp.95-101
    • /
    • 2012
  • Typically, large scale power generation facilities are linked to 345kV transmission line through a step-up transformer. If the value of transient voltage by generating lightning stroke is large more than electric equipment's BIL, devices insulation is destroyed. LA(Lighting Arrester) is used as a main means of prevention. However, the installation of LA takes the constraints of installation place and expensive installation costs. Therefore, we need to carefully study whether installation of installation can be omitted and the most efficient place of installation. In this paper, we simulated the transient voltage detected by lightning stroke at each equipments in the 345kV transmission power grid by using EMTP-RV program.

154 kV GIS의 PT 철공진 소손사례와 원인규명 (A analysis result on the PT ferroresonance at 154 kV GIS substation)

  • 우정욱;심응보;김승규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2076-2079
    • /
    • 1999
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP (Electro-magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

Clamping-diode Circuit for Marine Controlled-source Electromagnetic Transmitters

  • Song, Hongxi;Zhang, Yiming;Gao, Junxia;Zhang, Yu;Feng, Xinyue
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.395-406
    • /
    • 2018
  • Marine controlled-source electromagnetic transmitters (MCSETs) are important in marine electromagnetic exploration systems. They play a crucial role in the exploration of solid mineral resources, marine oil, and gas and in marine engineering evaluation. A DC-DC controlled-source circuit is typically used in traditional MCSETs, but using this circuit in MCSETs causes several problems, such as large voltage ringing of the high-frequency diode, heating of the insulated-gate bipolar transistor (IGBT) module, high temperature of the high-frequency transformer, loss of the duty cycle, and low transmission efficiency of the controlled-source circuit. This paper presents a clamping-diode circuit for MCSET (CDC-MCSET). Clamping diodes are added to the controlled-source circuit to reduce the loss of the duty ratio and the voltage peak of the high-frequency diode. The temperature of the high-frequency diode, IGBT module, and transformer is decreased, and the service life of these devices is prolonged. The power transmission efficiency of the controlled-source circuit is also improved. Saber simulation and a 20 KW MCSET are used to verify the correctness and effectiveness of the proposed CDC-MCSET.

전력설비 절연유 열팽창 계산식 개선에 관한 연구 (A study on the improvement of the thermal expansion formula of the insulating oil in electric facilities)

  • 임성황;문봉수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.153-156
    • /
    • 2001
  • The transformer and the OF cable are cooled and insulated by insulating oils in their body. The insulating oil expands or contracts with the heat transfer according to the operating conditions of the electric facilities. So we install the $N_2$ gas tank connected with the insulating oil system to overcome the change. The change of the insulating oil volume for the operation temperature range must be calculated to decide the $N_2$ gas volume and to set the alarm point for safe operation. It is known that this change is proportional to the temperature change and to the insulating oil volume if the temperature change is small enough.[1][11] However this proportional formula has been accepted generally in the design of electric facilities for wide operation temperature range such as $40^{\circ}C{\sim}125^{\circ}C$. Hence, it makes large errors in calculation which car result in serious damage against safe operation of the electric facilities. This paper presents a improved method of calculating the accurate change of the insulating oil volume to insure the safe operation of electric facilities.

  • PDF

154kV GIS 변전소 P.T. 철공진 규명 및 방지대책 (Investigation and Countermeasure of P.T Ferroresonance in the 154kV GIS Substation)

  • 최원수;김승규;지성구;김순태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.541-543
    • /
    • 2002
  • This paper describes the analysis resulates on the P.T ferroresonance at 154kV GIS(Gas Insulated Substation) by EMTP(Electromagnetic transient program). We had simulated the PT ferroresonance between a potential transformer(PT) and open circuit braker's grading capacitance. The ferroresonance leads to very large power frequency overvoltage on PT bus and subsequent insulation failure. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF