• 제목/요약/키워드: Large optical mirror

검색결과 93건 처리시간 0.025초

DESIGN CONSIDERATION FOR HIGH STABILITY TELESCOPE STRUCTURE

  • Lee, Deog-Gyu;Jang, Hong-Sul;Lee, Eung-Shik;Jung, Dae-Jun;Lee, Seung-Hoon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.225-228
    • /
    • 2005
  • Telescope structure based on Korsch type optical layout was suggested for a large aperture optical system. Korsch type optical layout is regarded as providing wide field of view and no color aberration for which high resolution space cameras greatly demand. For the suggested Korsch type telescope structure, two folding mirrors are adopted, firstly to provide for the refocusing device mounting plane on the second fold mirror assembly, secondly by double folding the light path to concisely confine focal plane assembly within the perimeter of the tube. Optical layput design and corresponding support structure design were attained.

  • PDF

Deep UV 마이크로 리소그라피를 위한 새로운 4-반사경 광학계에 관한 수차해석

  • 김종태;이상수
    • 한국광학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1993
  • 축소배율(5$\times$)을 갖고, Seidel 1차 수차중 4개의 비축수차인 코마(coma), 비점수차(astigmatism), 상면만곡(field curvature) 그리고 왜곡수차(distortion)가 제거된 마이크로 리소그라피를 위한 4-구면 반사경 광학계를 해석적으로 구하였다. 이때, $t=d_1+d_2+d_3$<0, (di는 반사거울 $c_i$$c_{i+1}$ 사이의 거리)이고, 축상 수차인 구면수차와 잔류고차수차는 반사거울 $c_3$$c_4$를 비구면화 하므로서 제거하였다. 이렇게 설계된 4-반사경 광학계의 N.A.는 0.4로서 Rayleigh분해능은 0.38 $\mu\textrm{m}$이다.

  • PDF

광선추적을 사용한 나사산 표면결함 검사용 환형 광학계 개발 (Development of Annular Optics for the Inspection of Surface Defects on Screw Threads Using Ray Tracing Simulation)

  • 이지원;임영은;박근;나승우
    • 한국정밀공학회지
    • /
    • 제33권6호
    • /
    • pp.491-497
    • /
    • 2016
  • This study aims to develop a vision inspection system for screw threads. To inspect external defects in screw threads, the vision inspection system was developed using front light illumination from which bright images can be obtained. The front light system, however, requires multiple side images for inspection of the entire thread surface, which can be performed by omnidirectional optics. In this study, an omnidirectional optical system was designed to obtain annular images of screw threads using an image sensor and two reflection mirrors; one large concave mirror and one small convex mirror. Optical simulations using backward and forward ray tracing were performed to determine the dimensional parameters of the proposed optical system, so that an annular image of the screw threads could be obtained with high quality and resolution. Microscale surface defects on the screw threads could be successfully detected using the developed annular inspection system.

스윙암 방식의 형상 측정기를 이용한 대형 반사경의 정밀가공에 관한 연구 (Study on Fabrication of a Large Concave Mirror Surface Using a Swing-Arm Type Profilometer)

  • 이기암;김옥현;이응석
    • 한국기계가공학회지
    • /
    • 제7권3호
    • /
    • pp.41-46
    • /
    • 2008
  • Generally optical components are fabricated by grinding, lapping and polishing processes. Those processes take long time to obtain optical high surface quality. In the case of large optical components, the on-machine measurement is strongly recommended because the workpiece is fragile and difficult to set up for fabricating and measuring. This paper is concerned about a swing-arm mechanism which can be used for on-machine measurement of a surface profile with a sensing probe end-effect, and also for grinding or lapping the surface with a corresponding tool. The measuring accuracy and uncertainty using a swing arm type profilometer have been studied. The experimental results show that this method is useful specially in lapping process with the accuracy of $5{\mu}m$. Those inspection data are provided for correcting the residual figuring error in next processes.

  • PDF

중대형 망원경을 이용한 관측연구 현황 (SURVEY ON THE OBSERVATIONAL RESEARCH ACTIVITIES USING MID-TO-LARGE SIZE TELESCOPES)

  • 우종학
    • 천문학논총
    • /
    • 제25권4호
    • /
    • pp.107-112
    • /
    • 2010
  • By joining the Giant Magellan Telescope (GMT) project, Korean astronomers will get 10% of the GMT time, starting in the late 2010s. To prepare the GMT era, it is important to evaluate the current observational research activities. We surveyed the research programs performed by domestic astronomers during 2007A - 2010A period, using optical/near - IR telescopes with a medium to large aperture mirror (larger than 4 m). We describe the method and criteria of the survey, and present the results of the analysis based on the collected data.

Design of an Optical System for a Space Target Detection Camera

  • Zhang, Liu;Zhang, Jiakun;Lei, Jingwen;Xu, Yutong;Lv, Xueying
    • Current Optics and Photonics
    • /
    • 제6권4호
    • /
    • pp.420-429
    • /
    • 2022
  • In this paper, the details and design process of an optical system for space target detection cameras are introduced. The whole system is divided into three structures. The first structure is a short-focus visible light system for rough detection in a large field of view. The field of view is 2°, the effective focal length is 1,125 mm, and the F-number is 3.83. The second structure is a telephoto visible light system for precise detection in a small field of view. The field of view is 1°, the effective focal length is 2,300 mm, and the F-number is 7.67. The third structure is an infrared light detection system. The field of view is 2°, the effective focal length is 390 mm, and the F-number is 1.3. The visible long-focus narrow field of view and visible short-focus wide field of view are switched through a turning mirror. Design results show that the modulation transfer functions of the three structures of the system are close to the diffraction limit. It can further be seen that the short-focus wide-field-of-view distortion is controlled within 0.1%, the long-focus narrow-field-of-view distortion within 0.5%, and the infrared subsystem distortion within 0.2%. The imaging effect is good and the purpose of the design is achieved.

오목거울을 이용한 3차원 형상측정을 위한 모아레 영상 획득 방법 (Image Enhancement for 3D Shape Measurement Using Large Aperture Projection System)

  • 윤두현;김학일
    • 한국광학회지
    • /
    • 제19권4호
    • /
    • pp.327-333
    • /
    • 2008
  • 일반적으로 NA(Numerical aperture)가 큰 렌즈를 사용하면 획득된 영상의 품질이 좋아진다. 오목거울은 NA가 크면서 직경이 크게 제작하는 비용이 저렴하다. 본 논문에서는3차원 형상 측정용 모아레 영상의 품질향상을 위해 NA가 큰 대구경 오목거울을 이용한 방법을 제안하고 구현하였다.오목거울은 빛을 반사하는 면이 오목한 거울로써, 가까운 거리에 있는 물체를 볼 때, 물체와 모양은 같고 크게 보이는 것이 특징이다. 보통의 경우, 작은 것을 크게 보거나 빛을 모으는데 이용한다. 오목거울의 집광 특징은 볼록거울과 방향만 다를 뿐 동일한 역할을 하고, 수 미터 직경의 대구경으로 제작하기 용이하며, 대구경이면서 $0.8{\sim}2$의 높은 NA를 갖는 오목거울을 구현하기 용이하다. 오목거울의 볼록 렌즈와 동일한 집광 특징을 이용하여 망원경 등의 반사경으로 많이 이용하고 있다. 3차원 영상획득 방법을 위해 필요한 장치는 광을 출사하는 광원,광원으로부터 출사된 광을 집광하기 위한 집광렌즈,집광렌즈를 통해 집광되어 입사되는 광을 투과시키는 격자,격자로부터의 출사 광을 평행광으로 출사하는 영사렌즈,영사렌즈의 평행광을 반사시켜 전량의 광을 측정대상물 쪽으로 출사하는 오목거울 그리고 측정 제품으로부터 반사된 반사광을 획득하는 CCD 카메라를 포함한다. 대구경 오목거울로 NA값을 변화시켜서 표면의 굴곡이 심한 납볼의 영상을 획득하여 품질향상 정도를 평가하였다. NA가 $0.15{\sim}0.8$까지 변화했을 때 영상 내 밝은 부분과 어두운 부분의 차이가 $46{\sim}1.33$배로 변화하여 NA를 높이면 영상의 품질이 향상됨을 알 수 있었다.

대형 비구면의 초정밀 가공을 위한 자동무수차점 방식의 널 렌즈 설계 및 측정 정밀도의 한계에 관한 연구 (A study for null lens design of autostigmatic type and the limitation of measurement accuracy for ultra precision manufacturing of large aspherical surface)

  • 김길선;임천석
    • 한국광학회지
    • /
    • 제16권1호
    • /
    • pp.71-78
    • /
    • 2005
  • 대형 비구면의 측정을 위하여 자동무수차점 방식의 2매 구성 널 렌즈를 설계하였고, 제작과 정렬 오차에 따른 측정 정밀도의 한계를 이론적으로 분석해 보았다. 측정 정밀도의 한계를 결정짓는 주요한 공차 요소는 널 렌즈면의 불규칙도(irregularity)임을 확인하였으며, 불규칙도의 가공 정도에 따라 5λ/100∼4λ/1000 정도까지의 신뢰할 수 있는 측정 정밀도가 한정지어졌다. 이로써 실제의 정렬 오차 및 널 렌즈 제작오차까지 고려하여 신뢰할 수 있는 정밀도 한계를 제시할 수 있었다.

위상 최적화 방법에 의해 설계된 대구경 구조물 (The Large Optical Structure Designed by Topology Optimization Methodology)

  • 이정익
    • 한국산학기술학회논문지
    • /
    • 제10권9호
    • /
    • pp.2179-2182
    • /
    • 2009
  • 최근, 광학기계시스템에 새로운 구조 모델은 저비용, 고성능 및 품질의 개념설계에서 출발해야 할 필요성이 있다. 이런 관점에서, 기계적 구조의 개념설계와 연관된 구조적-위상적 형상은 구조적 강성과 감량과 같은 시스템 성능에 큰 영향을 끼친다. 본 연구에서는, 최적설계방법이 대구경 구조물의 설계단계에 제시되었다. 먼저, 위상 최적화법을 이용하여 구조물의 최적 배열과 보강방안을 얻었고, 사이즈 최적화와 다분야 최적기법을 사용한 세부 설계를 수행하였다. 그 일례로, 이 방법들을 대구경 구조물 설계에 적용하였다.

A METHOD FOR TESTING SURFACE DEFORMS OF LARGE CONVEX MIRRORS

  • Kim Young-Soo
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2004년도 한국우주과학회보 제13권2호
    • /
    • pp.254-257
    • /
    • 2004
  • Both ground and space telescopes are being built larger and larger. Accordingly, the secondary mirrors become larger which are convex mostly on the surface form. Testing convex mirrors becomes more difficult and delicate than testing concave mirrors in optics, because additional optical components are needed to make the reflected rays converge. Hindle type tests are frequently used for measuring the surface deforms of convex mirrors, which employs a meniscus lens to reverse the diverted rays from the mirrors. In case of testing large convex mirrors by using Hindle type tests, attention would be needed as larger meniscus lens is required. A method of modified Hindle test has been studied and the characteristics are analyzed. In this paper, current method of testing convex mirrors is presented, and a new method is discussed.

  • PDF