A Study on Effect of Shotcrete Adhesive Strength on Large Section Rock Tunnel Stability (대단면 암반터널의 안정성에 미치는 숏크리트 부착강도의 영향에 관한 연구)

  • Chang, Seok-Bue;Hong, Eui-Joon;Moon, Sang-Jo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.4
    • /
    • pp.305-311
    • /
    • 2005
  • Shotcrete adhesive strength in large section tunnels in jointed rock masses plays an important role in preventing rock block from falling and shotcrete debonding due to blasting vibration. Nevertheless, it has not been considered as a major factor such as shotcrete compressive strength in design and construction. For this reason, the purpose of this study is to analyze the effect on shotcrete adhesive strength for large-sectioned tunnels. First, the parametric study using numerical model similar to Holmgren's punch-loaded test was executed for various range of adhesive strength. It shows that the shotcrete bearing capacity is linearly proportioned to the adhesive strength between shotcrete layer and blocks. And then, distinct element analysis of a jointed rock tunnel for an adhesive strength of 1 MPa and a conventional fully-bonded condition between the shotcrete layer and the excavation face was compared in order to evaluate the effect of the shotcrete adhesive strength.

  • PDF

Analysis on Seismic Resistance Capacity of Hollow Concrete Block Reinforced Foundation Ground by Using Shaking Table Test (진동대 시험을 이용한 중공블록 보강 기초의 내진성능분석)

  • Shin, Eun-Chul;Lee, Yeun-Jeung;Yang, Tae Chul
    • Journal of the Korean Geosynthetics Society
    • /
    • v.20 no.4
    • /
    • pp.85-93
    • /
    • 2021
  • The seventy percentage of Korean Peninsular is covered by the mountainous area, and the depth of west sea and south sea is relatively shallow. Therefore, a large scale land reclamation from the sea has been implemented for the construction of industrial complex, residental area, and port and airport facilities. The common problem of reclaimed land is consisted of soft ground, and hence it has low load bearing capacity as well as excessive settlement upon loading on the ground surface. The hollow concrete block has been used to reinforce the loose and soft foundation soil where the medium-high apartment or one-story industrial building is being planned to be built. Recently the earthquakes with the magnitude of 4.0~5.0 have been occurred in the west coastal and southeast coastal areas. Lee (2019) reported the advantages of hollow concrete block reinforced shallow foundation through the static laboratory bearing capacity tests. In this study, the dynamic behavior of hollow concrete block reinforced sandy ground with filling the crushed stone in the hollow space has been investigated by the means of shaking table test with the size of shaking table 1000 mm × 1000 mm. Three types of seismic wave, that is, Ofunato, Hachinohe, Artificial, and two different accelerations (0.154 g, 0.22 g) were applied in the shaking table tests. The horizontal displacement of structure which is situated right above the hollow concrete block reinforced ground was measured by using the LVDT. The relative density of soil ground are varied with 45%, 65%, and 85%, respectively, to investigate the effectiveness of reinforcement by hollow block and measured the magnitude of lateral movement, and compared with the limit value of 0.015h (Building Earthquake Code, 2019). Based on the results of shaking table test for hollow concrete block reinforced sandy ground, honeycell type hollow block gives a large interlocking force due to the filling of crushed stone in the hollow space as well as a great interface friction force by the confining pressure and punching resistance along the inside and outside of hollow concrete block. All these factors are contributed to reduce the great amount of horizontal displacement during the shaking table test. Finally, hollow concrete block reinforced sandy ground for shallow foundation is provided an outstanding reinforced method for medium-high building irrespective of seismic wave and moderate accelerations.

Field Installation Test of the Circular Steel Cofferdam Using Suction Pressure (석션압을 이용한 원형강관 가물막이 현장설치 실험)

  • Kim, Jae-Hyun;Xin, Zhen-Hua;Lee, Ju-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.10
    • /
    • pp.5-19
    • /
    • 2020
  • With increasing demand for offshore structures, the demand for temporary structures to help the offshore construction work has increased. A cofferdam is a temporary barrier to stop the inflow of water in the construction site and allows working in the dry condition when the construction is done within the water. However, it is a major cause of construction delays and increased costs because additional works are required to block the water inflow. Recently, in order to overcome the limitations of the conventional cofferdam methods and to increase economic efficiency, a large-diameter steel cofferdam method has been proposed which can be installed quickly in the seabed by using the suction pressure. In this circular steel cofferdam method, the top side of the cofferdam including the top-lid is always exposed above the sea level in order to use it as a water barrier, unlike the conventional suction bucket foundation. After installation, the top-lid of the cofferdam is removed and the water filled inside the cofferdam is discharged to make the interior dry condition. In this study, the circular steel cofferdam with a 5 m inner diameter was fabricated and the installation tests were conducted at the Saemaguem test site. During the experiment, variation of suction pressure, leakage between connections, structure deformation, and inclination of the steel cofferdam were measured and post-analyzed. This study verified the new circular steel cofferdam method and confirmed that the suction installation method can be successfully used for various purposes on offshore structures.

Analysis of Flood Reduction in Downstream Urban Areas for the Storage in Apartment Complex (하류 도심지 침수저감 분석을 통한 공동주택 단지의 우수저류조 계획)

  • Jae-Do Choi;Hyoung-Chul Lim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.698-709
    • /
    • 2023
  • Purpose: In this paper, we would like to analyze the growth rate of existing urban immersion in the downstream during large-scale urban development and the degree of reduction in existing urban immersion in the downstream when small excellent storage facilities are planned in apartment complexes. Method: A large-scale sewage model was built using the SWMM model of the U.S. Environmental Protection Agency, and the impact of flooding in existing downtown areas downstream was analyzed through simulation. The built model included the development zone, the existing downtown area downstream, and the entire river basin that discharges rainwater. Result: As a result of calculating and simulating the minimum excellent reservoir capacity for each apartment block in the study target area, it was found that the immersion of 4,893㎥ based on one hour, 25,815㎥ based on two hours, and 55,528㎥ based on three hours in the downstream urban area. Conclusion: As in this study, large-scale flooding simulation considering the existing downtown area in the downstream shows a significant increase in flooding in the downstream, and if excellent reservoir capacity is planned for each apartment block before development and the construction of excellent reservoirs is recommended.

The Business Model & Feasibility Analysis of the Han-Ok Residential Housing Block (한옥주거단지 사업모델구상 및 타당성 분석)

  • Choi, Sang-Hee;Song, Ki-Wook;Park, Sin-Won
    • Land and Housing Review
    • /
    • v.2 no.4
    • /
    • pp.453-461
    • /
    • 2011
  • This study is to derive a project model based on potential demand for Korean-style houses, focusing on new town detached housing sites that LH supplies and to test validity of the derived model and to present the direction and supply methods of the projects. The existing high-class new town Korean-style housing developments that have been considered were found to have little business value due to problems in choice of location and discordance of demand, so 6 types of projects were established through the methods of changes in planned scale, combined use, and subdivision of plot of land based on the results of survey. The type that has the highest business value among the project models was block-type multifamily houses, and this can be interpreted as the increase in total construction area leading to increase inrevenues of allotment sales due to economies of scale. The feasibility of mass housing model in which small-scale Korean-style houses are combined with amenities was found to be high, and if the same project conditions as those of the block-type multifamily houses are applied, the business value of the Korean-style tenement houses was found to be high. Besides, the high-class housing models within block-type detached housing areas are typical projects that the private sector generally promotes, and the construction cost was found to be most expensive with 910 million won per house. In order to enhance the business value of the Korean-style housing development, collectivization such as choice of location, diversification of demand classes, optimization of house sizes, and combination of uses is needed. And in order to adopt Korean-style houses in the detached housing sites, the adjustments and division of the existing planned plots are needed, and the strategies to cope with new demand through supplying Korean-style housing types of sites can be suggested. Also breaking away from the existing uniform residential development methods, the development method through supplying original land that is natural land not yet developed besides basic infrastructures (main roads and water and sewage) can be considered, and as the construction of more than 1~2 stories building is impossible due to the structure of Korean-style house roof and furniture. So it can be suggested that original land in the form of hilly land is considered to be most suitable to large-scale development projects.

A Modified Method for the Radial Consolidation with the Time Dependent Well Resistance (시간 의존적 배수저항을 고려한 방사방향 압밀곡선 예측법)

  • Kim, Rae-Hyun;Hong, Sung-Jin;Jung, Doo-Suk;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.77-84
    • /
    • 2008
  • The existing equations for radial consolidation cannot account for the changes of well resistance with time and cannot predict the appropriate in-situ consolidation curve. In this study, small cylinder cell tests are performed to evaluate the discharge capacity of PVD. Also, a block sample of 1.2 m in diameter and 2.0 m in height was consolidated to observe the change in the drainage capacity with time for three types of PVD. From the test results on a block sample, the drainage curves normalized with initial drainage of each PVD are similar, regardless of the PVD type and the consolidation curve, which is predicted using solutions of radial consolidation based on the discharge capacity measured in a small cylinder cell tests, significantly overestimates the degree of consolidation. The term of well resistance in the radial consolidation solution was back-calculated to fit the consolidation curve of a large block sample and it is defined as the time dependent well resistance factor, L(t). The L(t) was found to be linearly proportional to the dimensionless time factor, Th. It was also shown that the consolidation curve evaluated by using L(t) provides more accurate prediction than the existing solution.

Development of Precast Hollow Concrete Columns with Non-Shrink Mortar Grouting Type Splice Sleeve (무수축 모르타르 충진형 슬리브를 사용한 중공 프리캐스트 교각 개발)

  • Cho, Jae-Young;Lee, Young-Ho;Kim, Do-Hak;Park, Jong-Heon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.215-225
    • /
    • 2011
  • In general, the precast columns can obtain its homogeneous quality as they are produced in a factory with a hollow concrete block type by using high strength concrete, so that they can generate the reduction of dead load. Such a method of precast hollow concrete columns is already implemented in USA and Japan and used for connecting between blocks which use PC tendons. However, it is inevitable to have uneconomical construction with excessive cost in early stage when PC tendons are used. This study aims to develop an economical precast column with high quality and constructability which consists of only splice sleeve and general reinforcing bar without using PC tendons in order to reduce the construction period and cost. To achieve this goal, this study tested the performance of total 5 minimized models in the experiment with the variables such as hollowness, diameter of main reinforcement bar and cross-sectional size for the cross section of precast column by using grouting type splice sleeve which is a new type joint rebar. And it also verified the performance of column in the experiment for a large-sized model in order to overview its applicability by excluding large scale effect.

A Comparison Study on the Concentration of Total Welding Fume and Respirable Particulate Mass for Welding Workers of a Shipbuilding (조선소 용접작업자들의 총용접흄과 호흡성분진농도 비교연구)

  • Kang, Yong-Seon;Sim, Sang-Hyo;Lee, Song-Kwon;Bin, Sung-Oh;Choi, Eun-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.276-282
    • /
    • 2007
  • The purpose of this study is to assess the accurate state of the following: total welding fumes versus welding fumes in the air, respirable particulate mass, and exposure of dockyard welders to heavy metals. In addition, this study provides basic data for proposing improvements to create efficient and appropriate welding environments and to prevent occupational diseases. The subjects of this study were 94 laborers who worked at the block construction sites of large-scale dockyards located in Gyeongnam Province from March 2005 to June 2005. In order to collect samples on total welding fumes in the air and respirable particulate mass from the welders, Methods 0500 and 0600, established by the National Institute for Occupational Safety and Health (NIOSH), were used. The metals within the welding fumes were also analyzed using Inductively Coupled Plasma (ICP) under Method 7300 from NIOSH. The results of this research are summarized below. The geometric mean concentration of total welding fumes and that of respirable particulate mass were $4.11\;mg/m^3\;and\;3.53\;mg/m^3$, respectively. As a result of comparing the two measurement methods, there were significant differences (p<0.05) between the two groups for Ca, Cu, Cr, and Ni; however, there were no differences in Fe, Mg, Zn, Mg, Pb, and Cd. As a result of the analysis, the correlation between Mn and the concentration of heavy metals in the total welding fumes and respirable particulate mass was found to be -0.29, a significant negative correlation. The correlation between other heavy metals, however, was low. Finally, in the same total welding fumes, the correlation of Fe and Mg was high.

An Ergonomic Study of the Sleeve Pattern According to Arm Movement -on Expansion and Contraction of the Skin Surface of the Arm- (팔의 동작에 따른 소매 원형의 인간공학적 연구 -팔의 피부면 신축을 중심으로-)

  • 함옥상
    • Journal of the Korean Home Economics Association
    • /
    • v.19 no.3
    • /
    • pp.21-32
    • /
    • 1981
  • Clothing must have the individual beauty and the function that one can do one's body movement freely. therefore, from the human engineering view point, the exact measurement of the human body and the analysis of it's results must be applied to clothing because the arm works most. In this study, the skin surface of arm was investigated by shell made of Alginate of each movement. And by sometic method the rate of expansion and contraction of each section, inter-relation among the bust girth, axillary arm girth and scye girth and between the shoulder length right and the under axilla waist length were calculate4d. With these results, cap height, breadth of a sleeve and arm hole girth of existing sleeve pattern have been compared and analysed. The results are as follows; 1) According to the developmental figures of shell, the whole area change was small but that of shape was remarkable in M 4, 9, 13. The change of the Block 1 was particular. 2) Over arm length was contracted in all movements except M6 and under arm length expanded. The changes of sections a, b, c are large, while those of sections d, e are small. 3) In terms of latitudes, change of fore-arm region was small. The rate of scye girth varied from 14.3% of M13 to-5.6% of M2. The breadth of a sleeve expanded in all movements, and especially the front region expanded more than the back. 4) The relation between the shoulder length right and under axilla waist length, in all occasions, was contracted mutually, and one contracted, the other expanded. Therefore, in clothing construction when we consider the function of the arm it is better to widen the arm hole and the breadth of a sleeve at the same time than no widen the shoulder length by lowering the upper part of the upper side seam line.

  • PDF

Case Study on the Countermeasure Methods and Collapsed Sources of Segmental Retaining Wall Considering Site Conditions (시공환경을 고려한 블록식 보강토옹벽의 붕괴요인 분석 및 대책방안 사례연구)

  • Han, Jung-Geun;Cho, Sam-Deok;Jeong, Sang-Seom;Lee, Kwang-Wo;Kim, Ji-Sun
    • Journal of the Korean Geosynthetics Society
    • /
    • v.4 no.3
    • /
    • pp.35-43
    • /
    • 2005
  • The geosynthetic reinforced segmental retaining walls(SRW) are improved that the disadvantage of existed retaining wall and the workability in field. Recently, the segmental retaining wall is replacing the exited wall because it is quickly advanced to using by the block in-situ. The use, therefore, is increasing. But, the trends of the large scaled construction was developed that the problems likely to crack and collapse, those are caused of careless in design and construction of SRW not considering about various surrounding conditions. In this study, the cause analysis on destructed SRW was carried out that based on the datum of measured displacement of walls, rainfall features and ground sounding conditions. Also, the analysis of the global slope stability was carried out on collapsed section and non-collapsed section using critical equilibrium method. For the rational stability and analysis of slope including SRW structure, the site conditions including situations of topography, ground and histories of construction and collapse etc should be considered. The rational countermeasure methods for non-collapsed and collapsed areas may be sustained as much as possible current state.

  • PDF