• Title/Summary/Keyword: Large Fire

Search Result 924, Processing Time 0.024 seconds

A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.4 no.2
    • /
    • pp.3-13
    • /
    • 1990
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the ]after fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern Higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First. We are going to look history of the fire protection system and change course of that with the year and facility. Second, We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

Part II A Study on the Analysis and Improvement of Current Fire Protection Standard for Buildings (현행소방시설설치기준의 분석과 개선방안에 관한 연구II)

  • 정병재;이경회
    • Fire Science and Engineering
    • /
    • v.5 no.1
    • /
    • pp.5-14
    • /
    • 1991
  • Fire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modern higher buildings are increased. As fire is a first product that human make, it performed many profits and services for our mankind. Sometimes as it Is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various. With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility. Second. We say the frame system and special nature of the foreign fire prevent Act. Third. We understand the control reality of fire protection system. Fourth. We took out the merit of foreign fire prevent law and the problem of our current domestic system. The placing standard of proper fire protection facilities that be presented from this study are followed next. 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4) We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.

  • PDF

Analysis of the Relationship between the Number of Forest Fires and Non-Rainfall Days during the 30-year in South Korea

  • Songhee, Han;Heemun, Chae
    • Journal of Forest and Environmental Science
    • /
    • v.38 no.4
    • /
    • pp.219-228
    • /
    • 2022
  • This study examined the relationship between the number of forest fires and days with no rainfall based on the national forest fire statistics data of the Korea Forest Service and meteorological data from the Open MET Data Portal of the Korea Meteorological Administration (KMA; data.kma.go.kr) for the last 30 years (1991-2021). As for the trend in precipitation amount and non-rainfall days, the rainfall and the days with rainfall decreased in 2010 compared to those in 1990s. In terms of the number of forest fires that occurred in February-May accounted for 75% of the total number of forest fires, followed by 29% in April and 25% in March. In 2000s, the total number of forest fires was 5,226, indicating the highest forest fire activity. To analyze the relationship between regional distribution of non-rainfall periods (days) and number of forest fires, the non-rainfall period was categorized into five groups (0 days, 1-10 days, 11-20 days, 21-30 days, and 31 days or longer). During the spring fire danger season, the number of forest fires was the largest when the non-rainfall period was 11-20 days; during the autumn fire precaution period, the number of forest fires was the largest when the non-rainfall period was 1-10 days, 11-20 days, and 21-30 days, showing differences in the duration of forest fire occurrence by region. The 30-year trend indicated that large forest fires occurred only between February and May, and in terms of the relationship with the non-rainfall period groups, large fires occurred when the non-rainfall period was 1-10 days. This signifies that in spring season, the dry period continued throughout the country, indicating that even a short duration of consecutive non-rainfall days poses a high risk of large forest fires.

The Way for improvement of facility to strengthen accessibility of the site for fire department (소방대의 현장접근성 강화를 위한 설비의 개선방안)

  • Oh, Taek-Hum;Sung, Ja-Man;Pak, Chan-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.67-75
    • /
    • 2012
  • Because recently(July 14, 2011) fire occurred in the engine room of a moving taxi under Namsan Tunnel 1, 51 vehicles' driver and more than 250 passengers in the road tunnel were urgently evacuated with abandoned vehicles. Vehicle fires in Namsan Tunnel that day, Sufferers struggled to escape quickly difficult to escape the two-way by abandoned vehicles on the road and to fear many casualties by using vehicle fuel and combustible interior and the driver who is ignorant of vehicle accident continuous entered in the road tunnel had accessibility the site of fire department was more difficult. In this study, It is to investigate structure and basic materials, such as fire extinguish equipment and facilities for damage prevention and to analyze the problems and to plan improvement method of fire extinguish equipment, facilities for damage prevention and transportation facilities(Large traffic signs, Breaker, etc.) on the Namsan Tunnel that in the long-term plan is prepared to strengthen for accessibility of the site of fire department in case of Vehicle's fire.

A Study on the Analysis and Improvement methods of Emergency Medical Service Systems for Large Scaled Fire (대형화재에 대비한 응급의료체계에 관한 분석과 개선방안)

  • Lee, Maria
    • The Korean Journal of Emergency Medical Services
    • /
    • v.11 no.1
    • /
    • pp.41-52
    • /
    • 2007
  • In Korea, Crowds, as well as more complex and larger structures, have been caused more victims in the event of fire. In that situation, EMSS should have done triage the patients according to their severity in the field, treat with standard guidelines as like advanced burn life support and transfer to appropriate facility. But in many cases, they didn't practice like that. The purpose of this study is to give basic data for proper emergency medical services by analysing EMSS of large scaled fire in Korea and suggesting some improvement methods. The improvment methods are like this ; First, developing of protocols about burn patient is needed for EMT and dispatcher. Second, Legal approval for advanced treatment is needed for EMT. Third, Fire-helicoptors are needed in Daejeon and Jeju. And Emergency Medical Helicoptors are needed in EMSS. Forth, more advanced emergency medical centers of burn must be established. Sixth, more pocket-mask and burn sheet are needed for 119 rescuer. Finally, building owners must change inflammable materials as non-inflammable materials and educate fire-prevention and first-aid to employees.

  • PDF

Establishment of Fire Reliability Assessment Method for Structural Strength (화재시 구조강도에 대한 신뢰성 평가방법의 정립)

  • Park, Chang-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.54-62
    • /
    • 2017
  • This paper describes the behavior and failure probability of the basic structural members in a fire for the fire safety assessment of offshore structures. A fire safety assessment can be accomplished by comparing the fire resistance of the members with the fire severity of the heat load due to fire. The fire severity is represented as the maximum temperature of the members using the Eurocode 1 standard fire curve and heat transfer equation. On the other hand, the fire resistance is the limiting temperature calculated by a simplified formula in the case of simple structural members. Considering the complexity of FPSOs and offshore structures, a general-purpose structural analysis program should be used and the limiting temperature obtained by analyzing the structural strength of the members through an elasto-plastic analysis with a large deflection, and compared with the maximum temperature. Also, the equality of these two methods of evaluating the fire resistance was confirmed by comparing them. Following three criteria, the strength, serviceability and stability, three failure modes, namely the first failure of a hinge, large deflection and buckling, were chosen. The failure temperature was verified for each failure mode. using the AFOSM method in the equation of the fire severity and fire resistance, thereby giving the failure probability of the member. By applying these processes to the example of a beam and plate, the behavior of the structure and failure (temperature?) of each failure mode can be determined.

Large Eddy Simulation of Fire and Smoke Control in a Compartment with Large Openings (큰 개구부가 있는 공간의 화재와 제연의 대와류모사)

  • 박외철
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.7-12
    • /
    • 2003
  • A 50 kW polyurethane fire in a compartment of 4 m ${\times}$ 1 m ${\times}$ 1.5m with large openings similar to a subway station was simulated by a large eddy simulation to investigate the fire and smoke control. The NIST FDS, which employed a mixture fraction combustion model and a finite volume method for radiation, was utilized. Distribution of temperature and smoke particles was compared with in the lower and upper corridors for three different smoke control systems, ventilation, purge, and extraction, starting in 5 sec from the ignition of the fire. For the given geometries, the ventilation system showed the best smoke removal rate and lowest temperature distribution in the both corridors. It was confirmed that the purge system is not recommended for a subway station since the smoke removal rate of the purge system was worse than that without a smoke control system.

Analysis of Forest Fire Occurrence in Korea (한국의 산불발생 실태분석)

  • Lee, Si-Young;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.54-63
    • /
    • 2006
  • The number of forest fire under various conditions such as year, month, time, day of the week, region, damaged species, cause, and damaged area are checked, and the statistics of the forest fire causing materials in recent 14 years ('91-'04) are analyzed. The result shows that the year majority of forest fires had happened in last 14 year was 2001 and most of forest fire occurred in April, Sunday, around 14:00 to 15:00. The most damaged region is Gyeongsangbuk-Do, followed by Gangwon-Do, Jeollabuk-Do, and Gyeonggi-Do. The most damaged species is pine tree. The main causes of forest fires are accidental fire and incineration of a field boundary; however, recently, incendiarism is increased. The result of analysis on the damaged area shows that small fires under 5 ha occurred most frequently and large fires (over 30 ha) occurred mostly in Kangwon province (44.2%). The result also shows that the large forest fires (1,113 minutes) require 7.5 time more than the small forest fires (148 minutes). Especially, since average damaged area caused by large forest fire was about 470 ha per incident.

Dangerous tanker fire fighting measures (위험물 탱크로리 화재진압 방안)

  • Lee, Jung-Il
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.11a
    • /
    • pp.215-223
    • /
    • 2012
  • Or maybe moving dangerous goods tanks of motorists excluded from the scope of the supervision of the fire department and fire prevention education as a blind spot on the part of a large party evidence of markers of contamination loading of dangerous goods according to the type of education that can be handled only by preparing the institutional arrangements accident is blocking the moving path of Dangerous Goods moving tanks and loading dangerous goods on fire budget move the path that corresponds to the report received by securing the extinguishing agent is required to neutralize the ash and fire suppression and repression through skills training from large disasters in advance blocking devices should prepare that will.

  • PDF

The Study on Characteristics of Water Spray and Droplet from Fire Sprinkler Head (소화용 스프링클러 헤드의 살수분포 및 수적 특성에 대한 연구)

  • 추병길;최종욱;차경세
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.2
    • /
    • pp.13-21
    • /
    • 2001
  • The effect of water spray for the fire sprinkler depends on droples distribution over maximum possible floor area. The present study are carried out for the characteristics of water spray and droplets experimentally and numerically km two fire sprinkler heads which are CHM head and CHl heal CHl head is self-production and CHl head is widely used up to date. As the result of using CHM head, water spray and droplets are distributed over large area because CHM head has smooth surface and non-flamed shape. When the pressure of fire sprinkler head is low, SMD(sauter mean diameter) is large and when the pressure of fire sprinkler head is high, SMD is small.

  • PDF