• 제목/요약/키워드: Large Amplitude Sloshing

검색결과 9건 처리시간 0.029초

Free Surface Tracking for the Accurate Time Response Analysis of Nonlinear Liquid Sloshing

  • Cho Jin-Rae;Lee Hong-Woo
    • Journal of Mechanical Science and Technology
    • /
    • 제19권7호
    • /
    • pp.1517-1525
    • /
    • 2005
  • Liquid sloshing displays the highly nonlinear free surface fluctuation when either the external excitation is of large amplitude or its frequency approaches natural sloshing frequencies. Naturally, the accurate tracking of time-varying free surface configuration becomes a key task for the reliable prediction of the sloshing time-history response. However, the numerical instability and dissipation may occur in the nonlinear sloshing analysis, particularly in the long-time beating simulation, when two simulation parameters, the relative time-increment parameter a and the fluid mesh pattern, are not elaborately chosen. This paper intends to examine the effects of these two parameters on the potential-based nonlinear finite element method introduced for the large amplitude sloshing flow.

비선형 경계조건을 고려한 내부 유체의 3차원 자유수면 유동해석 (3-D analysis of sloshing motion in a fluid container with nonlinear boundary conditions)

  • 김문겸;임윤묵;조경환;박종헌;이성민
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.177-184
    • /
    • 2002
  • Large amplitude sloshing can occur in contained fluid region due to the seismic ground motion. Also, The pressure by large amplitude sloshing damages the connections between the wall and roof of a fluid container and causes outflow of contained fluid. Therefore, to predict the dynamic behavior accurately, three dimensional analysis with the nonlinear boundary condition must be performed. In this study, the numerical solution procedure is developed using the boundary element method with the Lagrangian particle approach. In order to demonstrate the accuracy and validity of the developed method, the fluid motion for a free oscillation with small amplitude and a forced vibration are analyzed. And the numerical results are compared with the linear theory results and the previous studies with the nonlinear boundary condition.

  • PDF

격막 설치에 따른 비선형 슬로싱 특성 연구 (Characteristic Analysis of Nonlinear Sloshing in Baffled Tank)

  • 이홍우;조진래
    • 대한기계학회논문집A
    • /
    • 제29권11호
    • /
    • pp.1455-1462
    • /
    • 2005
  • In this paper, we intend to introduce a nonlinear finite element method based on the fully nonlinear potential flow theory in order to simulate the large amplitude sloshing flow in two-dimensional baffled tank subject to horizontally forced excitation. The free surface is tracked by a direct time differentiation scheme with the four-step predictor-corrector time integration method. The flow velocity is accurately recovered from the velocity potential by second-order least square method. In order to maintain the finite element mesh regularity and total mass, the semi-Lagrangian surface tracking method with area conservation is applied. According to the numerical formulae, we perform the parametric experiments by varying the installation height and the opening width of baffles, in order to examine the effects of baffle on the nonlinear liquid sloshing. From the numerical results, the hydrodynamic characteristics of the large amplitude sloshing are investigated.

사각용기의 슬로싱 유동에 관한 연구 (Study of Sloshing Flow in a Rectangular Tank)

  • 지영무;신영섭;박준상;현재민
    • 대한기계학회논문집B
    • /
    • 제35권6호
    • /
    • pp.617-624
    • /
    • 2011
  • 본 연구에서는 사각용기 내에서의 자유표면을 갖는 2차원 슬로싱 문제에 대하여 고찰하였다. 용기 내부의 유동은 수평방향의 조화운동을 통해 형성되며, 외부 가진 속도는 u=Asin($2{\pi}ft$)으로 정의 된다. 여기서 u, A�� 그리고 f는 외부로부터 작용하는 가진 속도, 변위 그리고 주파수를 각각 나타낸다. 큰 변위(A~O(1)) 슬로싱 문제의 해석을 위한 실험설비를 구축하였으며, 광범위한 영역에서의 PIV실험을 수행하였다. 실험을 통해 자유표면의 움직임(motion)을 각각 서로 다른 물리적 특성을 갖는 세 가지; 선형 슬로싱의 자유표면의 움직임과 유사한 standing wave motion, 사각용기의 속도가 0을 지나는 순간(the moment of turn-over) 측벽에서 발생하는 run-up motion 그리고 측벽으로부터 내부유체로 점차적으로 전파되는 bore motion으로 분류하였다.

유한요소법을 이용한 2차원 사각탱크내 비선형 슬로싱 동응답 해석 (Dynamic Response Analysis of Nonlinear Sloshing in Two Dimensional Rectangular Tank using Finite Element Method)

  • 조진래;이홍우;하세윤;박태학;이우용
    • 한국전산구조공학회논문집
    • /
    • 제16권1호
    • /
    • pp.33-42
    • /
    • 2003
  • 본 논문에서는 2차원 사각탱크내 비압축성, 비점성, 비회전 유동에 대한 비선형 슬로실 해석을 다룬다. 유체영역의 지배방정식으로 포텐셜 이론에 기반을 둔 라플라스 방정식을 사용한다. 대변형의 슬로싱 거동을 표현하기 위하여 베르누이 방정식으로부터 유도된 운동 및 동역학적 자유표면 경계조건을 적용한다. 이러한 비선형 슬로싱 문제는 9결점 요소를 사용한 유한요소법에 의하여 해석되어 진다. 경계조건에 대한 시간적분과 정확한 속도계산을 위하여 각각 예측자-수정자 기법 및 최소자승법을 도입하였다. 또한, 자유표면 추적에서 야기되는 안정성 문제는 시간변동에 대한 자유표면 위치를 직접 계산함으로써 확보할 수 있었다. 외부 조화가진에 대한 본 논문의 결과는 선형이론해 또는 참고문헌의 결과와 비교하여 매우 정확하고 안정적이었다. 프로그램 검증 후, 유체높이와 가진크기에 대한 슬로싱 응답특성을 분석하였다.

Seismic response analysis of an unanchored vertical vaulted-type tank

  • Zhang, Rulin;Cheng, Xudong;Guan, Youhai;Tarasenko, Alexander A.
    • Earthquakes and Structures
    • /
    • 제13권1호
    • /
    • pp.67-77
    • /
    • 2017
  • Oil storage tanks are vital life-line structures, suffered significant damages during past earthquakes. In this study, a numerical model for an unanchored vertical vaulted-type tank was established by ANSYS software, including the tank-liquid coupling, nonlinear uplift and slip effect between the tank bottom and foundation. Four actual earthquakes recorded at different soil sites were selected as input to study the dynamic characteristics of the tank by nonlinear time-history dynamic analysis, including the elephant-foot buckling, the liquid sloshing, the uplift and slip at the bottom. The results demonstrate that, obvious elephant-foot deformation and buckling failure occurred near the bottom of the tank wall under the seismic input of Class-I and Class-IV sites. The local buckling failure appeared at the location close to the elephant-foot because the axial compressive stress exceeded the allowable critical stress. Under the seismic input of Class-IV site, significant nonlinear uplift and slip occurred at the tank bottom. Large amplitude vertical sloshing with a long period occurred on the free surface of the liquid under the seismic wave record at Class-III site. The seismic properties of the storage tank were affected by site class and should be considered in the seismic design of large tanks. Effective measures should be taken to reduce the seismic response of storage tanks, and ensure the safety of tanks.

Floating Gas Power Plants

  • Kim, Hyun-Soo
    • 한국산업융합학회 논문집
    • /
    • 제23권6_1호
    • /
    • pp.907-915
    • /
    • 2020
  • Specification selection, Layout, specifications and combinations of Power Drives, and Ship motions were studied for FGPP(Floating Gas-fired Power Plants), which are still needed in areas such as the Caribbean, Latin America, and Southeast Asia where electricity is not sufficiently supplied. From this study, the optimal equipment layout in ships was derived. In addition, the difference between engine and turbine was verified through LCOE(Levelized Cost of Energy) comparison according to the type and combination of Power Drives. Analysis of Hs(Significant Height of wave) and Tp(spectrum Peak Period of wave) for places where this FGPP will be tested or applied enables design according to wave characteristics in Brazil and Indonesia. Normalized Sloshing Pressures of FGPP and LNG Carrier are verified using a sloshing analysis program, which is CFD(Computational Fluid Dynamics) software developed by ABS(American Bureau of Shipping). Power Transmission System is studied with Double bus with one Circuit Breaker Topology. A nd the CFD analysis allowed us to calculate linear roll damping coefficients for more accurate full load conditions and ballast conditions. Through RAO(Response Amplitude Operator) analysis, we secured data that could minimize the movement of ships according to the direction of waves and ship placement by identifying the characteristics of large movements in the beam sea conditions. The FGPP has been granted an AIP(Approval in Principle) from a classification society, the ABS.

Seismic control of structures using sloped bottom tuned liquid dampers

  • Bhosale, Amardeep D.;Murudi, Mohan M.
    • Structural Engineering and Mechanics
    • /
    • 제64권2호
    • /
    • pp.233-241
    • /
    • 2017
  • Earlier numerous studies have been done on implementation of Tuned Liquid Damper (TLD) for structural vibration control by many researchers. As per current review there is no significant study on a sloped bottom TLD. TLD's are passive devices. A TLD is a tank rigidly attached to the structure and filled partially by liquid. When fundamental linear sloshing frequency is tuned to structure's natural frequency large sloshing amplitude is expected. In this study set of experiments are conducted on flat bottom and sloped bottom TLD at beach slope $20^{\circ}$, $30^{\circ}$ and $45^{\circ}$, for different types of structures, mass ratio, and depth ratio to investigate the overall effectiveness of TLD and specific effect of TLD parameters on structural response. This experimental study shows that a properly designed TLD reduces structural response. It is also observed that effectiveness of TLD increases with increase in mass ratio. In this experimental study an effectiveness of sloped bottom TLD with beach slope $30^{\circ}$ is investigated and compared with that of flat bottom TLD in reducing the structural response. It is observed from this study that efficiency of sloped bottom TLD in reducing the response of structure is more as compared to that of flat bottom TLD. It is shown that there is good agreement between numerical simulation of flat bottom and sloped bottom TLD and its experimental results. Also an attempt has been made to investigate the effectiveness of sloped bottom TLD with beach slope $20^{\circ}$ and $45^{\circ}$.

유체-구조물-지반 상호작용을 고려한 면진된 유체저장탱크의 3차원 지진응답 (Seismic Response of Base-Isolated Liquid Storage Tanks Considering Liquid-Structure-Soil Interaction)

  • 조성용;김문겸;임윤묵
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 추계 학술발표회 논문집
    • /
    • pp.98-105
    • /
    • 2002
  • The effects of the base-isolation system and elastic soil foundation on the behavior of a liquid storage tank are studied. To evaluate the seismic response of liquid storage tank accurately, the coupled dynamic system considering base isolation and soil interaction problem is formulated in time domain. Results show that the base isolation system reduces effectively the radial displacements, base shears, overturning moments, axial resultant stresses and the hydrodynamic pressure by providing flexibility and energy dissipation capability. Base Isolation may, however, increase the relative liquid sloshing amplitude due to the effect of liquid-structure interaction and cause excessive large relative displacements between structure and foundation. In addition to base-isolator, the dynamic behavior of liquid storage tank is related to the flexibility of base foundation, so the analysis of soil-structure interaction s achieved.

  • PDF