• Title/Summary/Keyword: Lap time

Search Result 115, Processing Time 0.021 seconds

A Study on a Visual Sensor System for Weld Seam Tracking in Robotic GMA Welding (GMA 용접로봇용 용접선 시각 추적 시스템에 관한 연구)

  • 김재웅;김동호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.643-646
    • /
    • 2000
  • In this study, we constructed a preview-sensing visual sensor system for weld seam tracking in real time in GMA welding. A sensor part consists of a CCD camera, a band-pass filter, a diode laser system with a cylindrical lens, and a vision board for inter frame process. We used a commercialized robot system which includes a GMA welding machine. To extract the weld seam we used a inter frame process in vision board from that we could remove the noise due to the spatters and fume in the image. Since the image was very reasonable by using the inter frame process, we could use the simplest way to extract the weld seam from the image, such as first differential and central difference method. Also we used a moving average method to the successive position data of weld seam for reducing the data fluctuation. In experiment the developed robot system with visual sensor could be able to track a most popular weld seam, such as a fillet-joint, a V-groove, and a lap-joint of which weld seam include planar and height directional variation.

  • PDF

Research on the Torque and Starting Characteristics of a Turbopump Turbine (터보펌프 터빈의 토크 및 시동특성 연구)

  • Jeong, Eunhwan;Lee, Hang-Gi;Park, Pyun-Goo;Hong, Moongeun;Kim, Jinhan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.35-41
    • /
    • 2013
  • Torque characteristics of a turbopump turbine was analyzed using the turbine performance test result. Specific torque of the subject turbine could be expressed as a linear function of corrected rotor speed at a fixed pressure ratio and it has been confirmed by the test result. It also found that corrected rotor speed-specific torque characteristics does not change anymore if the turbine pressure ratio is set bigger than a certain value. Using the turbine torque characteristics and pyro-starter performance test results, rotational speed development behavior of the turbopump was predicted. Prediction revealed that the lap time reaching 50% of turbopump design speed is less than 0.7 second. Effect of the thermal loss between pyro-starter and turbopump was negligible.

A Study on the Mechanism of Crevice Corrosion for 430 Stainless Steel (430 스테인리스강의 틈부식 발생기구에 대한 연구)

  • 백신영;나은영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.447-452
    • /
    • 2003
  • Crevice corrosion is localized form of corrosion usually associated with a stagnant solution on the micro-environmental level. Such stagnant micro environments tend to occur in crevices (shielded areas) such as those formed under gaskets washers insulation material. fastener heads. surface deposits. disbonded coatings. threads. lap joints and clamps. Crevice corrosion is initiated by changes in located electrochemical reaction within the crevice such as a) depletion of inhibitor in the crevice b) depletion of oxygen in the crevice c) a shift to acid conditions in the crevice and d) build-up of aggressive ion species (e.g chloride) in the crevice. In this study. the mechanism of crevice corrosion for Type 430 stainless steel is investigated undercondition that the size of specimen is $15{\times}20\{times}3mm$, in 1N $H_2SO_4$ + 0.05N NaCl solution. and the artificial crevice gap size of 3 x 0.2 x 15 mm. Crevice corrosion is measured under applied potential -300mV(SCE) to the external surface. The obtained result of this study showed that 1) the induced time for initiation of crevice is 750 seconds. 2) potential of the crevice was about from -320mV to -399mV. which is lower than that of external surface potential of -300mV It is considered that potential drop in the crevice is one of mechanisms for the crevice corrosion

A Consideration on the Process Technology and Application of MEMS to prepare for upcoming MEMS-based technological paradigm (MEMS 기반의 새로운 기술적 패러다임에 대비한 공정 기술 분석 및 적용에 대한 고찰)

  • Ko, Yun-Seok
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.7
    • /
    • pp.979-986
    • /
    • 2013
  • Recently, in the electric, electronic, robotic, and medical industries, a great attention has been paid to the development of MEMS-based smart devices with a compact size and highly intelligency. The MEMS technology is very effective in designing into a compact size and lightweight by combining into one the complex electrical, mechanical, chemical, and biological features which are required by smart devices, and at the same time, in bulk batch manufacturing. Therefore, this study, to prepare for upcoming new MEMS-based technological paradigm, analyzes MEMS processes and then considers its Applications.

Development of Integrated CAE System for Mechanical Shock Proof Design of TFT-LCD Modules (TFT-LCD 모듈의 내충격성 향상을 위한 통합 CAE 시스템의 개발)

  • 서형원;문성인;구자춘;최재붕;김영진;최성식;이정권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.9
    • /
    • pp.135-141
    • /
    • 2004
  • Anti-shock performance is one of the most important design specifications of TFT-LCD modules. Since they are adopted fur major display units of many mobile applications such as lap-top PCs, cellular phones, and palm pilots, they are able to accommodate and endure high level transient mechanical energy inputs. For the reasons, not only the LCD unit manufacturers but their customers like PC makers perform a series of strict impact/drop test on the units. Currently, designers are mostly relying on their own trial-error based experience for the anti-shock design. Thus those designs depending on only experience may result in disqualification from the drop/impact test during final product evaluation. Those shock failures of any new designs are prohibitive for both LCD and PC manufacturers. In order to avoid this problem, many designers are focusing on the development of computer-aided design tools that is directly connected to shock simulation capabilities and then shock-proof design cycle time could be significantly reduced. Development of an integrated CAE system for the shock-proof design is presented in this article. At every stages of the development of present work, practical industrial applicability and mass production feasibility are seriously considered and tested so that the system is to be used in the LCD design engineering field.

Research on the Torque and Starting Characteristics of a Turbopump Turbine (터보펌프 터빈의 토크 및 시동특성 연구)

  • Jeong, Eun-Hwan;Lee, Hang-Gi;Park, Pyun-Goo;Hong, Moon-Geun;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.4-10
    • /
    • 2012
  • Torque characteristics of a 75-tonf turbopump turbine was analyzed using the turbine performance test result. Specific torque of the subject turbine could be expressed as a linear function of corrected rotor speed at a fixed pressure ratio and it has been confirmed by the test result. It also found that corrected rotor speed-specific torque characteristics does not change anymore if the turbine pressure ratio is set bigger than a certain value. Using the turbine torque characteristics and pyro-starter performance test results, rotational speed development behavior of the turbopump was predicted. Prediction revealed that the lap time reaching 50% of turbopump design speed is less than 0.7 second. Effect of the thermal loss between pyro-starter and turbopump was negligible.

  • PDF

Diffusion Enhancement during Electrically Assisted Brazing of Ferritic Stainless Steel Alloys

  • Luu, Viet Tien;Dinh, Thi Kieu Anh;Das, Hrishikesh;Kim, Ju-Ri;Hong, Sung-Tae;Sung, Hyun-Min;Han, Heung Nam
    • International Journal of Precision Engineering and Manufacturing-Green Technology
    • /
    • v.5 no.5
    • /
    • pp.613-621
    • /
    • 2018
  • The electrically assisted brazing of a ferritic stainless steel with nickel-based filler metal is experimentally investigated. During electrically assisted brazing of a lap joint, the temperature of the joint is first rapidly increased to a brazing temperature and held nearly constant for a specific period using a pulsed electric current. Microstructural analysis results strongly suggest that the electric current during electrically assisted brazing enhances diffusion between the filler metal and the ferritic stainless steel, thus inducing significantly thicker diffusion zones compared with induction brazing. The mechanical test results show that the strength of the electrically assisted brazing joint is comparable to or even superior to those of the joint fabricated by induction brazing, while the process time of the electrically assisted brazing is significantly shorter than that of induction brazing.

Effects of Ultrasound on the Flexibility of the Waist after Stretching at the Erector Spinae in Normal Adults (척주세움근의 스트레칭 후 초음파 적용이 정상 성인의 허리 유연성에 미치는 영향)

  • Won-jye Choi
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.29 no.3
    • /
    • pp.55-61
    • /
    • 2023
  • Background: The purpose of this study was to determine whether applying ultrasound after stretching the erector spinae muscle is an effective method for normal adults as a way to restore reduced back flexibility that causes back pain. Methods: The study was conducted on 60 healthy volunteers divided randomly into four groups (control group, stretching group, ultrasound group, ultrasound after stretching group). The flexibility-promoting effects were determined by assessing, each group, at the time of treatment, pre and post by modified fingertip to-floor (MFTF) and active straight leg raising (ASLR). The data were analyzed using the two-way ANOVA repeated measure with significant level α=.05. Results: Each group showed statistically significant changes in MFTF distance and ASLR degree. In the post-hoc test about this result, the length of MFTF and degree of ASLR in ultrasound after stretching group increased significantly compared to the others. Conclusion: The results suggest that using ultrasound after stretching is far more effective in increasing the flexibility of the erector spinae than using stretching or ultrasound intervention.

  • PDF

New Methods of Producing Copper Sulfate Crystals Using Small-Scale Chemistry(SSC) in Elementary School Science (초등과학에서 미량화학(SSC)을 이용한 황산구리 결정 만들기의 새로운 방법)

  • Han, Sang-Joon;Kim, Sung-Kyu
    • Journal of Environmental Science International
    • /
    • v.17 no.9
    • /
    • pp.981-992
    • /
    • 2008
  • This study examined how to produce new methods of copper (II) sulfate crystallization by using a small-scale chemistry tool such as small-scale reaction surface and petri dish. The making of copper(II) sulfate is included in the 5th grade elementary science textbooks. Various copper(II) compounds were reacted with a 2 M sulfuric acid solution. The result of this study is as follows: Seven small amounts of copper(II) compounds were reacted with a few drops of 2 M sulfuric acid solution at room temperature to make a copper(II) sulfate crystal of triclinic shape. Using the petri dish method, a copper(II) sulfate crystal could be identified within one hour of reacting copper(II) hydroxide, copper(II) carbonate, copper(II) nitrate, copper(II) perchlorate, cupric(II) formate from a few drops of 2 M sulfuric acid solution at room temperature. When using the lap top method for copper(II) perchlorate, cupric formate, a proper crystal could be identified within one hour as well. SSC methods were used for the first time to make a copper sulfate crystal via chemical reaction. We can make a copper(II) sulfate crystal using a simple method which is easier, safer and saves time in class. And since a small quantity of chemicals are being used in SSC chemical methods, waste is greatly reduced. This lessens the amount of environmental problems caused by the experiment. This can be helpful in preserving nature. In addition the cost of chemical and laboratory equipment is greatly reduced because it uses material that we find in our daily lives. There will be continued study of small-scale methods such as improvement of new programs, study and training of teachers, and securing SSC tools. I would like to suggest such as SSC methods are applicable in elementary School Science. I would like it to become a wide spread program.

Intracorporeal Esophagojejunostomy Using a Circular or a Linear Stapler in Totally Laparoscopic Total Gastrectomy: a Propensity-Matched Analysis

  • Kang, So Hyun;Cho, Yo-Seok;Min, Sa-Hong;Park, Young Suk;Ahn, Sang-Hoon;Park, Do Joong;Kim, Hyung-Ho
    • Journal of Gastric Cancer
    • /
    • v.19 no.2
    • /
    • pp.193-201
    • /
    • 2019
  • Purpose: There is no consensus on the optimal method for intracorporeal esophagojejunostomy (EJ) in laparoscopic total gastrectomy (LTG). This study aims to compare 2 established methods of EJ anastomosis in LTG. Materials and Methods: A total of 314 patients diagnosed with gastric cancer that underwent LTG in the period from January 2013 to October 2016 were enrolled in the study. In 254 patients, the circular stapler with purse-string "Lap-Jack" method was used, and in the other 60 patients the linear stapling method was used for EJ anastomosis. After propensity score matching, 58 were matched 1:1, and retrospective data for patient characteristics, surgical outcome, and post-operative complications was reviewed. Results: The 2 groups showed no significant difference in age, body mass index, or other clinicopathological characteristics. After propensity score matching analysis, the linear group had shorter operating time than the circular group ($200.3{\pm}62.0$ vs. $244.0{\pm}65.5$, $P{\leq}0.001$). Early postoperative complications in the circular and linear groups occurred in 12 (20.7%) and 15 (25.9%, P=0.660) patients, respectively. EJ leakage occurred in 3 (5.2%) patients from each group, with 1 patient from each group needing intervention of Clavien-Dindo grade III or more. Late complications were observed in 3 (5.1%) patients from the linear group only, including 1 EJ anastomosis stricture, but there was no statistical significance. Conclusions: Both circular and linear stapling techniques are feasible and safe in performing intracorporeal EJ anastomosis during LTG. The linear group had shorter operative time, but there was no difference in anastomosis complications.