• Title/Summary/Keyword: Landfill leachate

Search Result 365, Processing Time 0.026 seconds

Innovative Technology of Landfill Stabilization Combining Leachate Recirculation with Shortcut Biological Nitrogen Removal Technology (침출수 재순환과 생물학적 단축질소제거공정을 병합한 매립지 조기안정화 기술 연구)

  • Shin, Eon-Bin;Chung, Jin-Wook;Bae, Woo-Keun;Kim, Seung-Jin;Baek, Seung-Cheon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.9
    • /
    • pp.1035-1043
    • /
    • 2007
  • A leachate containing an elevated concentration of organic and inorganic compounds has the potential to contaminate adjacent soils and groundwater as well as downgradient areas of the watershed. Moreover high-strength ammonium concentrations in leachate can be toxic to aquatic ecological systems as well as consuming dissolved oxygen, due to ammonium oxidation, and thereby causing eutrophication of the watershed. In response to these concerns landfill stabilization and leachate treatment are required to reduce contaminant loading sand minimize effects on the environment. Compared with other treatment technologies, leachate recirculation technology is most effective for the pre-treatment of leachate and the acceleration of waste stabilization processes in a landfill. However, leachate recirculation that accelerates the decomposition of readily degradable organic matter might also be generating high-strength ammonium in the leachate. Since most landfill leachate having high concentrations of nitrogen also contain insufficient quantities of the organic carbon required for complete denitrification, we combined a shortcut biological nitrogen removal (SBNR) technology in order to solve the problem associated with the inability to denitrify the oxidized ammonium due to the lack of carbon sources. The accumulation of nitrite was successfully achieved at a 0.8 ratio of $NO_2^{-}-N/NO_x-N$ in an on-site reactor of the sequencing batch reactor (SBR) type that had operated for six hours in an aeration phase. The $NO_x$-N ratio in leachate produced following SBR treatment was reduced in the landfill and the denitrification mechanism is implied sulfur-based autotrophic denitrification and/or heterotrophic denitrification. The combined leachate recirculation with SBNR proved an effective technology for landfill stabilization and nitrogen removal in leachate.

Development of Stability Index for Defining the End of the Post-closure Monitoring Period for MSW Landfill (폐기물매립지의 사후관리종료 평가를 위한 안정화 지수 산정에 관한 연구)

  • Lee, Nam-Hoon;Han, Jeong-Hyun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.14 no.2
    • /
    • pp.63-70
    • /
    • 2006
  • The purpose of this study was to develop the stability index of landfill sites to assess it's degree of stability. In order to develop the stability index, field data including leachate qualities, Landfill gas (LFG) composition and element composition of wastes from 50 closed landfills were collected. Three parameters-BOD/CODcr among leachate quality parameters, $CH_4$ among landfill gases, and C/N ratio from wastes-were found to be the best parameters for measuring the stability of landfill sites. The trend line of these parameters were used to Also, $CH_4$ from landfill gases and C/N ratio from wastes were found to be the best parameters. The trend lines of these parameters were used to develop the stability index of landfill sites. The equation for the index was as following; $I_{LS}=S_L+S_G+S_W$ $S_L=-\{4.892+16.587{\cdot}ln[BOD/COD_{Cr]\}$ $S_G=53.872-12.782{\cdot}ln[CH_4]$ $S_W=79.382-20.013{\cdot}ln[C/N]$ (The maximum score for $S_L$, $S_G$, and $S_W$ was 33.3.) where, $I_{LS}$ : The stability index of the landfill $S_L$ : The stability score of the leachate $S_G$ : The stability score of the landfill gas $S_W$ : The stability score of the waste.

  • PDF

Performance Evaluation of Close Waste Landfill Vertical Slurry Wall(SCW) by Tracer Method (추적자조사기법을 활용한 사용종료매립장 연직차수벽 성능평가)

  • Lee, Dong-Geon;Oh, Young-In;Kim, Kwan-Ho;Cho, Sook-Hee;Bak, Eun-Suk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1245-1252
    • /
    • 2010
  • Many industrialized countries are confronted with a difficulty about reuse of closed waste landfill. facilities. Especially, the demand of closed waste landfill maintenance and reuse nearby urban area has been increased, because of the shortage of usable land and extend of urban area. For the safe reuse of closed waste landfill, the most important check point is the effect of waste landfill on environment abound them. However, the non-sanitary closed waste landfill generally have no leachate lining system, therefore, the in-situ lining system such as sheet-pile, and vertical slurry wall etc. was needed to prevent the leachate outgoing from the waste landfill. In this paper present the case history of performance evaluation of vertical slurry wall by tracer tests.

  • PDF

The Numerical Modeling Study for the Simultaneous Flow of Leachate and LFG in Kimpo Landfill (수도권 매립지에서 침출수-가스의 동시 유동 해석을 위한 전산 모델링 연구)

  • 성원모;박용찬;이광희
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.6 no.2
    • /
    • pp.101-106
    • /
    • 1999
  • Open dump of refuse causes groundwater and soil contamination by leachate and air pollution by LFG(Landfill Gas). In this paper, in order to perform a study about reduction of high leachate and LFG collection & control, using a 3-D, 2-phase, transient FDM model, the analysis of simultaneous flow of leachate and LFG has been carried out. In present numerical analysis it is assumed that 58 percents of LFG will evaporate to the ambient air and the recharge rate of a landfill be 12 percent of the average precipitation per year. All other data were excerpted at the point of 1995 when three refuse layers had been buried. From numerical analysis we concluded that maximum head value is approximately 26 mH2O<-에이치투오 (2.52 atm) in the center of the system and that installing venting trench plays an important role in landfill stabilization. Evan with the assumption of three layers constructed and low recharge rate applied, it is found that cumulative leachate and LFG productions will be 15.1 million 세제곱미터, 5.58 billion 세제곱미터, respectively after 40 years.

  • PDF

Sensitivity Analysis of the Leachate Level of a Landfill to Hydraulic Properties of Cover Soil and Waste (매립장의 복토재와 폐기물 수리특성에 대한 침출수위의 민감도 분석)

  • 주완호;장연수;김용인
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.5 no.2
    • /
    • pp.110-115
    • /
    • 1998
  • In this paper, the sensitivity of the leachate level is analyzed using the program HELP to reduce the high leachate level on the landfill. Hydraulic parameters analyzed were porosity, field capacity, wilting point and initial water content of cover soil and waste. Also, the influence of the difference between the initial water content and the field capacity on the leachate level in the landfill was analyzed. The results of the sensitivity analysis show that the increase of the porosity and the wilting point decreases the leachate level, while the increase of the field capacity and the hydraulic conductivity increases the leachate level. Major parameters to the change of the leachate level were the hydraulic conductivity in the case of cover soil and the porosity, the field capacity and the initial water content in the case of waste.

  • PDF

Analysis of the Basement Structure of Noeun Waste Landfill Site Using a Refracted Elastic Wave Tomography Survey (탄성파 굴절법 토모그래피 방법을 이용한 노은 폐기물 매립장의 지반 구조 분석)

  • Kim, Jun-Kyoung
    • Journal of the Korean earth science society
    • /
    • v.27 no.4
    • /
    • pp.425-432
    • /
    • 2006
  • A seismic tomography using refraction waves is applied to provide information on depth of basement rocks and leachate distribution of the Noeun waste landfill site for the stage of preliminary environmental survey. This method is generally applied to civil and environmental areas. Three lines, apparently perpendicular to the potential leachate flow direction in this site, were installed to investigate the waste landfill site in pseudo three dimensional geometry. The results show that the site is composed of 3 layers and depth of basement becomes shallower at the upstream area of the landfill site than that of the downstream area. Moreover, some parts of the second layer and the basement at the down stream area are partially infiltrated by the leachate, probably related to the disturbed distribution of the different velocity materials within the second layer. In Conclusion, refraction wave tomography is found to be one of the most efficient way to investigate waste landfill site.

Settlement and Sliding Possibility of the Foundation of the Waste Landfill Constructed on Natural Marine Clay (자연 해성점토 위에 건설한 폐기물매립장 기호지반의 침하와 활동 가능성)

  • 김수삼;강기민
    • Geotechnical Engineering
    • /
    • v.12 no.5
    • /
    • pp.41-54
    • /
    • 1996
  • In this paper, the consolidation settlement of the landfill foundation during and after the period of disposal is analyzed using the program CONSOL which can include the influence of waste load and the leachate level into the analysis. the stability analysis of the embankment is also performed under the varied strength of foundation soil which results from the increase of effective stress due to consolidation of the clay under the landfill. The predicted settlement from CONSOL is compared with the field measured settlement. The results show that, when the leachate level increases with the increase of waste height, the increase of the effective stress of foundation clay is negligible and the stability of the slope of the landfill may not be secured as the disposal of the waste proceeds. Several complementary repairworks, e. g. the reduction of current slope of the fill, application of drain methods to stop or reduce !he leachate level are recommended. The predicted settlement consists moderately with the field measured settlement.

  • PDF

천안.원주 불량매립지의 수리지질 및 수리지구화학 비교

  • Lee Jin-Yong;Yun Hui-Seong;Lee Seong-Sun;Cheon Jeong-Yong;Gwon Hyeong-Pyo;Kim Jong-Ho;Kim Chang-Gyun;Park Jeong-Gu
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.394-397
    • /
    • 2006
  • Hydrogeologic and hydrochemlcat conditions of two uncontrolled landfills without reliable underlying liners, leachate collection and treatment systems were compared. With similar weather conditions, spatial distribution and temporal variations of contaminants of concern and redox parameters were different for the two landfills. These differences are highly associated with ages and hydrogeologic settings of the landfills. Groundwater flow diverges from the Cheonan landfill while it converges to downgradient area in the Wonju landfill. Less permeable clayey silt layer or silty soil in the subsurface limited dispersion of leachate plume in the former landfill but highly permeable sandy soil with good lateral extent facilitated rapid plume dispersion in the latter landfill. In addition, hydraulic properties of the cover soil played a role in the different development of redox conditions, which resulted in significantly different concentrations of nitrates. Most problematic contaminants at downgradient wells of the landfills are ammonia and nitrate.

  • PDF

Long Term Trend and Stability of Contaminant Sources of Finished Landfill (사용종료 매립장 오염원의 장기 변화 및 안정성)

  • 장연수
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1996.12a
    • /
    • pp.1-40
    • /
    • 1996
  • In order to determine the proper treatment of the finished landfill, it is important to predict the trend and stability of the major sources of contaminant in the landfill. In this paper the fate of contaminant sources in the landfill is studied from various literatures by grouping the contaminants into waste, leachate, and landfill gas. One example site referred is Nanji landfill which is one of the representative finished landfills in our country and the trend of contaminant sources in this landfill at current stage is discussed.

  • PDF

Dipole-Dipole Resistivity Survey on the Side of Han River near Nanjido Landfill (난지도에 인접한 한강변에서의 쌍극자-쌍극자 전기탐사)

  • Lee, Kiehwa;Kwon, Byung-Doo;Oh, Seok-Hoon;Kim, Cha-Seop
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.335-343
    • /
    • 1996
  • The dipole-dipol electrical resistivity survey was conducted to investigate the probable contamination of the Han river by leachate from the near-by Nanjido Landfill. The survey line of 3 km was set along the unpaved road toward the Han river. For the convenience of the field work, the survey line was divided into four segments. The complete two-dimensional resistivity section was constructed by connecting the inversion result of each segment. Gravity survey was also carried out along the profile parallel to the resistivity line. Near surface resistivity generally appeared to be of very low value in most part of the survey area and the boundary between the alluvium layer and underlying basement rocks is well discriminated on the resistivity section. These results agree well with those of the preceding Schlumberger depth sounding made at adjacent area by Lee and fun (1995). The variation of thickness of the alluvium layer delineated by gravity anomaly profile also correlates well with the result of the resistivity survey on the qualitative basis. The problem of contamination by leachate from the Nanjido Landfill, where various waste materials have been dumped without any proper treatment facilities, has been remains unsolved yet. Therefore, we present the most probable passages of leachate flow based on the survey results and have briefly discussed about measure for contamination control. Considering the thickness of alluvium and the possible existence of fractured zone, the middle point between 1st and 2nd landfill and the midst of 1st landfill are the most hazardous regions to make leachates flow into the Han river. Since large amounts of leachates are observed from the test wells located on the lines extending from the border between the 1st and 2nd landfill and the middle of the lst landfill, contamination protection barriers are strongly recommended near these regions.

  • PDF