• Title/Summary/Keyword: Lancing device

Search Result 5, Processing Time 0.02 seconds

Development of the Electric Lancing Device and the Lancet to Prevent the Secondary Contamination by Needlestick Injury (채혈바늘에 의한 2차 감염 방지기능을 갖는 랜싯과 전동식 채혈기의 개발)

  • Hong, Sung-Chul;Jang, Seok-Jin;Kang, Shin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5464-5468
    • /
    • 2011
  • This paper deals with the development of the safety lancet and the electric lancing device. The safety lancet, in which a needle and a protective cap become one body, is designed. It is to prevent the secondary contamination by needlestick injury because the needle is always in the protective cap except for a moment of blood-gathering. The electric lancing device powered by batteries is devised to be operated by the moving rod of solenoid hitting the lancet. and to be used after selecting the repeat or the single hitting mode. The impact force by a hitting rod, the expected life of battery and etc. are measured for product development. This lancing device can be also used for the bloodletting device of the oriental medicine.

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

Vacuum Assisted Auto-Lancing Technique for Capillary Blood Sampling on the Forearm with Minimized Pain (전완부위 최소통증 채혈을 위한 진공 자동 채혈기법)

  • Park Mi Sook;Park Kyung Soon;Kim Kyung Ah;Jun Myung Hee;Kim Tae Im;Lee Tae Soo;Cha Eun Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.557-563
    • /
    • 2004
  • A new vacuum assisted auto-lancing technique is proposed to minimize pain. Specially designed lancing device was introduced, which applied -100mmHg right after skin puncture on the forearm. Sampled blood volumes were measured in 58 normal females. Mean volume of 464 samples was approximately 2.6$\muL$ and the frequency of more than 0.5$\muL$ was 86%. Thus the success rate of blood sugar test should also be the same when using modern glucose meters capable of testing with only 0.3~0.5$\muL$ of capillary blood. When pain scores were quantitatively evaluated by the visual pain measure, only 23% pain of the traditional finger sampling was experienced, demonstrating that capillary blood sampling was performed on the forearm with almost no pain. The present technique reduced pain to a great degree, though resampling might be unavoidable due to 14% of test failure rate estimated for modern glucose meters. However, minimized pain makes the present technique of great convenience for diabetic patients who need blood sampling a few times a day.

Development of the Electric Lancing Device and the Lancet to Prevent the Secondary Contamination by Needlestick Injury (채혈바늘에 의한 2차 감염 방지기능을 갖는 랜싯과 전동식 채혈기의 개발)

  • Hong, Sung-Chul;Jang, Seok-Jin;Kang, Shin-Han
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.11b
    • /
    • pp.820-823
    • /
    • 2010
  • 본 연구는 채혈바늘에 의해 발생하는 2차 감염을 방지하기 위한 안전 랜싯(Lancet)을 설계 개발하고 연속하여 채혈하는 경우에 쉽게 그리고 편리하게 사용할 수 있도록 무선 전동방식의 채혈기를 설계제작을 목적으로 한다. 안전랜싯은 채혈침과 보호캡이 일체형으로 설계되어 채혈 순간을 제외하고는 채혈침이 항상 보호캡 속에 있도록 하여 채혈바늘에 의한 사고를 방지하도록 하였다. 전동 채혈기는 충전건전지를 전원으로 하고 솔레노이드의 작동으로 랜싯을 타격하여 채혈하도록 설계되었으며, 연발 타격 또는 단발타격의 기능을 선택하도록 설계 제작되었다. 이 채혈기는 한방병의원의 사혈기로도 사용되도록 제작되었다.

  • PDF

A Study on Dynamic Characteristics of 3-axis Actuator for the Slim Type Pick-Up (3축 구동이 가능한 Slim형 Pick-Up Actuator 개발 및 동특성 분석)

  • 박관우;서민석;홍삼열;김영중;최인호;김진용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.373-377
    • /
    • 2002
  • In this study, we suggested a slim-type actuator that can be controlled in radial direction for compensating coma aberration in high-capacity optical storage devices. To deal successfully with narrow space in slim-type optical pick-up for notebook pc device, additional yokes for tilting motion are integrated into main yoke of the actuator. And the location of tilting coils is determined for mass-b3lancing effect to achieve optimal configuration for high driving sensitivity. We also suggested new concept of lens holder to guarantee excellent stability of control system by enhancing the gain margin at secondary resonant frequency. The concept was realized by forming damping sections in the lens holder, which prevent vibrational energy from transferring to lens. An exclusive measurement system was newly developed for fast and precise measurement of dynamic characteristics of actuators and utilized for the practical use. We hope to make good use of this system also in time to come.

  • PDF