• Title/Summary/Keyword: Lancing

Search Result 36, Processing Time 0.029 seconds

Design of a Partial Inter-tube Lancing System actuated by hydraulic power for type F model Steam Generator in Nuclear Power Plant (수압구동 전열관다발 부분 삽입형 증기발생기 세정장비 설계)

  • Kim, S.T.;Jeong, T.W.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1132-1135
    • /
    • 2008
  • The sludge grown up in steam generators of nuclear power plants shortens the life-cycle of steam generators and reduces the output of power plants. So KHNP(Korea Hydro and Nuclear Power), the only nuclear power utility in Korea, removes it periodically using a steam generator lancing system during the outage of plants for an overhaul. KEPRI(Korea Electric Power Research Institute) has developed lancing systems with high pressured water nozzle for steam generators of nuclear power plants since 2001. In this paper, the design of a partial inter-tube lancing system for model F type steam generators will be described. The system is actuated without a DC motor inner steam generators because the motors in a steam generator make a trouble from high intensity of radioactivity as a break down.

  • PDF

A Study on the Development of Lancing Process Method Using Forming Analysis (성형해석을 이용한 랜싱공법 개발에 관한 연구)

  • Jung, Dong-Won;Ko, Dae-Lim
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.1
    • /
    • pp.171-177
    • /
    • 2008
  • The characteristics of sheet metal process are little loss of material during process, the short processing time and the excellent price and strength. It has been widely used in autobody, electronic components, aircraftbody, etc. Lancing is a press operation in which a single-line cut or slit is made on part way across the strip stock, without removing any metal. In this paper, we examined the validity of finite element method analysis on the automobile CTR-PLR -L/R stamping process by using the lancing engineering method. As a result, it has shown that the proper lancing engineering method could prevent fracturing by improving sheet metal flow.

DEVELOPMENT OF A STEAM GENERATOR LANCING SYSTEM

  • Jeong Woo-Tae;Kim Seok-Tae;Hong Sung-Yull
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.391-398
    • /
    • 2006
  • It is recommended to clean steam generators of nuclear power plants during plant outages. Under normal operations, sludge is created and constantly accumulates in the steam generators. The constituents of this sludge are different depending on each power plant characteristics. The sludge of the Kori Unit 1 steam generator, far example, was found to be composed of 93% ferrous oxide, 3% carbon and 1% of silica oxide and nickel oxide each. The research to develop a lancing system that would remove sludge deposits from the tubesheet of a steam generator was started in 1998 by the Korea Electric Power Research Institute (KEPRI) of the Korea Electric Power Corporation (KEPCO). The first commercial domestic lancing system in Korea, the $KALANS^(R)-I$ Lancing System, was completed in 2000 for Kori Unit 1 for cleaning the tubesheet of its Westinghouse Delta-60 steam generator. Thereafter, the success of the development and site implementation of the $KALANS^(R)-I$ lancing system for YGN Units 1&2 and Ulchin Units 3&4 was also realized in 2004 for sludge removal at those sites. The upper bundle cleaning system for Westinghouse model F steam generators is now under development.

A Numerical Study on Combustion Characteristics for Various Configurations of Oxy-PC Burners (전산유동 해석을 이용한 Oxy-PC 버너 형상 변화에 따른 화염 특성 연구)

  • Chae, Taeyoung;Ryu, Changkook;Yang, Won
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.43-46
    • /
    • 2012
  • The oxygen concentration of primary oxidizer is decided under 10% due to flammable risk. It can be a spontaneous combustion inside burner or tube if the excess oxygen is added to primary oxidizer in Oxy-PC burner. In this case, the rest oxygen which can not be injected to primary oxidizer should be injected to another port. If added it to a second oxidizer, the ignition is unstable at outlet of burner. Accordingly an extra lancing port is needed to insert into the burner unlike other common air mode. And the flame formation and combustion characteristic differ from lancing port position. Therefore we observed flame formation which has stable combustion characteristic according to the shape and position of lancing port.

  • PDF

A Study of Tool Planning for FRT-PLR-L/R Stamping Process by using Forming Analysis (성형해석을 이용한 프론트 필라의 성형 공법 개발에 관한 연구)

  • Jung, Dong-Won;Ko, Dae-Lim
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.890-896
    • /
    • 2008
  • Sheet metal forming is one of the most useful and important method in manufacturing of the autobody panels because of the excellent production rate. The objectives of sheet metal forming processes are getting a desired geometrical shape of products with good quality, low cost and reasonable lead time. In this paper, we examined the validity of finite element method analysis on the automobile FRT-PLR-L/R stamping process by using the lancing engineering method. Lancing is a press operation in which a single-line cut or slit is made on part way across the strip stock, without removing any metal. As a result, it has shown that the proper lancing engineering method could prevent fracturing by improving sheet metal flow.

The effect of oral breast milk on pain response of the neonates during heel lancing (모유경구투여가 발뒤꿈치 천자 시 신생아의 통증반응에 미치는 효과)

  • Kim, Kyunghwa;Park, Youngim;Kim, Taeim
    • Journal of the Korean Data and Information Science Society
    • /
    • v.27 no.1
    • /
    • pp.203-215
    • /
    • 2016
  • This study was performed in order to investigate the effect of breast milk on pain relief in newborn during heel lancing. Nonequivalent control group pretest-posttest design by double blinded experiment was used. 50 neonates were randomized to receive breast milk (experimental group, n=25) or no treatment (control group, n=25) before undergoing heel lancing. Informed consent was obtained from parents of 50 neonates. Neonatal infant pain scale (NIPS), respiration rate, heart rate, oxygen saturation, and crying duration were used to assess subjects' pain reaction. Data were analyzed using SPSS 18.0. The experimental and control group showed a statistically significant differences in NIPS score (F=28.89, p<.001), heart rate (F=14.03, p<.001), respiration rate (F=4.79, p=.001), oxygen saturation (F=2.69, p=.027), and crying duration (t=-8.78, p <.001) at each time points (during heel lancing, right after heel lancing, 1, 2, 3 minutes after heel lancing). The result suggest that oral administration of expressed breast milk is safe and natural agents for reducing procedural pain of neonates. Another clinical trial study with more samples is recommended.

Pain and Blood Volume with Different Sampling Sites and Puncture Depths in Vacuum Assisted Auto Lancing Technique for Blood Glucose Test (혈당검사를 위한 진공자동채혈기법사용시 채혈부위와 바늘침투깊이에 따른 통증과 채혈량 분석)

  • Park, Mi-Sook;Park, Kyung-Soon;Kim, Kyung-Ah;Cha, Young-Joo;Jun, Myung-Hee;Kim, Tae-Im;Lee, Tae-Soo;Cha, Eun-Jong
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.2
    • /
    • pp.265-271
    • /
    • 2006
  • Purpose: To analyze the newly developed vacuum assisted auto-lancing technique applied to the forearm for the purpose of obtaining an adequate blood sample for glucose test with minimal pain. Methods: Visual and facial pain measures were introduced to compare lancing pain between the forearm and fingertip in 58 normal females. Sampled blood volumes were accurately measured by computer scanning technique. Results: Visual pain measure demonstrated significant pain reduction effect of the forearm sampling compared with the traditional fingertip sampling, which was also consistent with facial pain measure results. Blood volume more than $0.5{\mu}L$, enough for blood glucose testing with modern glucometers, was collected in 399(86%) of 464 forearm samples. Conclusions: Capillary blood sampling could be performed with minimal pain on the forearm by the newly developed vacuum assisted auto-lancing technique. With some resampling when necessary, the forearm sampling seemed very useful, considering almost no pain felt by the patients.

  • PDF

Development of the Electric Lancing Device and the Lancet to Prevent the Secondary Contamination by Needlestick Injury (채혈바늘에 의한 2차 감염 방지기능을 갖는 랜싯과 전동식 채혈기의 개발)

  • Hong, Sung-Chul;Jang, Seok-Jin;Kang, Shin-Han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5464-5468
    • /
    • 2011
  • This paper deals with the development of the safety lancet and the electric lancing device. The safety lancet, in which a needle and a protective cap become one body, is designed. It is to prevent the secondary contamination by needlestick injury because the needle is always in the protective cap except for a moment of blood-gathering. The electric lancing device powered by batteries is devised to be operated by the moving rod of solenoid hitting the lancet. and to be used after selecting the repeat or the single hitting mode. The impact force by a hitting rod, the expected life of battery and etc. are measured for product development. This lancing device can be also used for the bloodletting device of the oriental medicine.